1910.68(b)(10) Bottom Arrangement
Go To Full Code Chapter
1910.68(b)(10)(i) Bottom Landing
At the bottom landing the clear area shall be not smaller than the area enclosed by the guardrails on the floors above, and any wall in front of the down-running side of the belt shall be not less than 48 inches from the face of the belt. This space shall not be encroached upon by stairs or ladders.
1910.68(b)(10)(iii) Mounting Platform
A mounting platform shall be provided in front or to one side of the uprun at the lowest landing, unless the floor level is such that the following requirement can be met: The floor or platform shall be at or above the point at which the upper surface of the ascending step completes its turn and assumes a horizontal position.
1910.68(b)(10)(iv) Guardrails
To guard against persons walking under a descending step, the area on the downside of the manlift shall be guarded in accordance with subparagraph (8) of this paragraph. To guard against a person getting between the mounting platform and an ascending step, the area between the belt and the platform shall be protected by a guardrail.
1910.68(b)(10)(ii) Location of Lower Pulley
The lower (boot) pulley shall be installed so that it is supported by the lowest landing served. The sides of the pulley support shall be guarded to prevent contact with the pulley or the steps.
Related Code Sections
1910.68(b)(10) Powered Platforms, Manlifts, and Vehicle-Mounted Work Platforms, Bottom Arrangement
At the bottom landing the clear area shall be not smaller than the area enclosed by the guardrails on the floors above, and any wall in front ...
1910.213(p) Machinery and Machine Guarding, Sanding Machines
the rolls so as to remain in adjustment for any thickness of stock. The bottom of the guard should come down to within three-eighths inch of a plane ...
1910.68(b)(11) Powered Platforms, Manlifts, and Vehicle-Mounted Work Platforms, Top Arrangements
A top clearance shall be provided of at least 11 feet above the top terminal landing. This clearance shall be maintained from a plane through each ...
1910.265(c)(24)(viii) Special Industries, Socketing, Splicing, and Seizing
Bottom sheaves shall be protected by close fitting guards to prevent cable from jumping the sheave ...
1910.181(a) Materials Handling and Storage, Definitions Applicable to This Section
means a derrick in which the boom is hinged from a cross member between the bottom ends of two upright members spread apart at the lower ends ...