1704.7.4.1 Boring and/or Test Pit Report
JUMP TO FULL CODE CHAPTER
The special inspector shall prepare a written report that includes statements attesting to the following: that borings were performed in accordance with the procedures established in Section 1802.5, that 100 percent of the borings and test pits were witnessed directly by the designated special inspection agency, the identification of those borings, the name of the individual special inspectors that witnessed the borings and/or test pits; confirmation that the borings and/or test pits were made and carried to the depths indicated; that to the best of the special inspector's knowledge and belief, the description and classification of the soils are a true description of the samples recovered from the respective borings and/or test pits: that such samples were recovered at the levels indicated; and that the boring and/or test pit work progressed in such manner that the samples recovered are reasonably representative of the subsurface conditions.
Related Code Sections
1704.7.4.1 Structural Tests and Special Inspections, Boring and /or Test Pit Report
, the description and classification of the soils are a true description of the samples recovered from the respective borings and/or test pits: that such samples ...
NYC Building Code 2008 > 17 Structural Tests and Special Inspections > 1704 Special Inspections > 1704.7 Soils > 1704.7.4 Special Inspection of Soils Investigations, Borings and Test Pits > 1704.7.4.1 Boring and /or Test Pit Report
1704.7.4.1 Structural Tests and Special Inspections, Boring and/or Test Pit Report
with the procedures established in Section 1802.5, that 100 percent of the borings and test pits were witnessed directly by the designated special ...
NYC Building Code 2014 > 17 Structural Tests and Special Inspections > 1704 Special Inspections > 1704.7 Subsurface Conditions > 1704.7.4 Special Inspection of Subsurface Investigations, Borings and Test Pits > 1704.7.4.1 Boring and/or Test Pit Report
§27-720 Foundations, Boring and Test Pit Operations
of borings and/or test pits shall be attested to as follows: (a) The architect or engineer shall file a report stating which borings and/or test pits were ...
§27-664 Foundations, Test Pits
(a) Test pits may be substituted for boring on a one-for-one basis. All applicable requirements as to depth, numbers of samples, data to be reported ...
1802.4 Soils and Foundations, Investigation
Soil classification shall be based on observation and any necessary tests of the materials disclosed by borings, test pits or other subsurface ...
NYC Building Code 2008 > 18 Soils and Foundations > 1802 Foundation and Soils Investigations > 1802.4 Investigation