G2411.2.2 Bonding Clamp
JUMP TO FULL CODE CHAPTER
The bonding jumper shall be connected to the gas piping system with a bonding clamp that is listed for the material of the bonding jumper and for the material of the component of the gas piping system to which the bonding clamp is attached. The bonding clamp shall be attached to the gas piping system on the downstream side of the gas meter or regulator, in an unconcealed and readily accessible space. The bonding clamp shall be attached to a segment of metallic fuel gas pipe which (a) is a component of the gas piping system, (b) is electrically continuous with all CSST components of the gas piping system, (c) is made of steel or wrought-iron, (d) complies with Section G2414.4.2 of this code and with all other applicable provisions of Section G2414 of this code, and (e) is not less than 3 inches (76 mm) in length. Neither the CSST nor the brass hexagonal nut on the CSST fitting shall be used as an attachment point for the bonding clamp.
Related Code Sections
310.2.2 General Regulations, Bonding Clamp
The bonding jumper shall be connected to the gas piping system with a bonding clamp that is listed for the material of the bonding jumper ...
Fuel Gas Code 2015 of New York State > 3 General Regulations > 310 (IFGS) Electrical Bonding > 310.2 Gas Pipe Bonding — CSST > 310.2.2 Bonding Clamp
310.2.2 General Regulations, Bonding Clamp
The bonding jumper shall be connected to the gas piping system with a bonding clamp that is listed for the material of the bonding jumper ...
2020 Fuel Gas Code of NYS > 3 General Regulations > 310 Electrical Bonding > 310.2 Gas Pipe Bonding—CSST > 310.2.2 Bonding Clamp
310.2.2 General Regulations, Bonding Clamp
The bonding jumper shall be connected to the gas piping system with a bonding clamp that is listed for the material of the bonding jumper ...
2010 Fuel Gas Code of NY > 3 General Regulations > 310 Electrical Bonding > 310.2 Gas Pipe Bonding - Systems That Contain CSST > 310.2.2 Bonding Clamp
G2411.2.2 Fuel Gas, Bonding Clamp
The bonding jumper shall be connected to the gas piping system with a bonding clamp that is listed for the material of the bonding jumper ...
2010 Residential Code of NY > 24 Fuel Gas > G2411 (310) Electrical Bonding > G2411.2 (310.2) Gas Pipe Bonding—Systems That Contain CSST > G2411.2.2 Bonding Clamp
G2411.2.2 Fuel Gas, (310.2.2) Bonding Clamp
The bonding jumper shall be connected to the gas
piping system with a bonding clamp that is listed for the material of the bonding jumper ...
Residential Code 2015 of New York State > 24 Fuel Gas > G2411 (310) Electrical Bonding > G2411.2 (310.2) Gas Pipe Bonding — CSST > G2411.2.2 (310.2.2) Bonding Clamp