R606.8 Bond
JUMP TO FULL CODE CHAPTER
When masonry units are laid in stack bond, horizontal joint reinforcement shall be placed in bed joints at not more than 16 inches (406 mm) on center. Horizontal joint reinforcement shall be a minimum of 9-gage and shall be in addition to required vertical reinforcement, Joint reinforcement shall be embedded in accordance with R606.13.6.
Related Code Sections
Section E3609 Services, Bonding
Bonding shall be provided where necessary to ensure electrical continuity and the capacity to conduct safely any fault current likely to be imposed ...
Section E3609 Services, Bonding
Bonding shall be provided where necessary to ensure electrical continuity and the capacity to conduct safely any fault current likely to be imposed ...
Section E4204 Swimming Pools [Electrical Provisions], Bonding
The equipotential bonding required by this section shall be installed to reduce voltage gradients in the pool area as prescribed ...
Section E4204 Swimming Pools [Electrical Provisions], Bonding
The equipotential bonding required by this section shall be installed to reduce voltage gradients in the prescribed areas of permanently installed ...
E4209.4 Swimming Pools [Electrical Provisions], Bonding
All metal piping systems and all grounded metal parts in contact with the circulating water shall be bonded together using an insulated, covered ...
2014 FBC - Residential, 5th edition > 42 Swimming Pools [Electrical Provisions] > E4209 Hydromassage Bathtubs > E4209.4 Bonding