• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects General Contractor Building Official & Plans Examiner Inspectors Owner Subcontractors Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Suggested code sections
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

2109.2.3.1 Bolts

Building Code 2018 of Wyoming > 21 Masonry > 2109 Empirical Design of Adobe Masonry > 2109.2 Adobe Construction > 2109.2.3 Allowable Stress > 2109.2.3.1 Bolts
JUMP TO FULL CODE CHAPTER

Bolt values shall not exceed those set forth in Table 2109.2.3.1.

TABLE 2109.2.3.1

ALLOWABLE SHEAR ON BOLTS IN ADOBE MASONRY

DIAMETER OF BOLTS
(inches)
MINIMUM EMBEDMENT
(inches)
SHEAR
(pounds)
1/2——
5/812200
3/415300
7/818400
121500
11/824600

For SI: 1 inch = 25.4 mm, 1 pound = 4.448 N.

Related Code Sections


2109.2.3.1 Masonry, Bolts
Bolt values shall not exceed those set forth in Table 2109.2.3.1. TABLE 2109.2.3.1 ALLOWABLE SHEAR ON BOLTS IN ADOBE MASONRY DIAMETER OF ...
Building Code 2018 of Wyoming > 21 Masonry > 2109 Empirical Design of Adobe Masonry > 2109.2 Adobe Construction > 2109.2.3 Allowable Stress > 2109.2.3.1 Bolts
2109.3.3.1 Masonry, Bolts
Bolt values shall not exceed those set forth in Table 2109.3.3.1. TABLE 2109.3.3.1 ALLOWABLE SHEAR ON BOLTS IN ADOBE MASONRY DIAMETER ...
Building Code 2015 of Wyoming > 21 Masonry > 2109 Empirical Design of Masonry > 2109.3 Adobe Construction > 2109.3.3 Allowable Stress > 2109.3.3.1 Bolts
2204.2 Steel, Bolting
The design, installation and inspection of bolts shall be in accordance with the requirements of Sections 2205, 2206, 2207, 2210 and 2211. For ...
Building Code 2015 of Wyoming > 22 Steel > 2204 Connections > 2204.2 Bolting
2204.2 Steel, Bolting
The design, installation and inspection of bolts shall be in accordance with the requirements of Sections 2205, 2206, 2207, 2210 and 2211. For ...
Building Code 2018 of Wyoming > 22 Steel > 2204 Connections > 2204.2 Bolting
1010.1.9.4 Means of Egress, Bolt Locks
Manually operated flush bolts or surface bolts are not permitted. Exceptions: On doors not required for egress in individual dwelling units ...
Fire Code 2015 of Wyoming > 10 Means of Egress > 1010 Doors, Gates and Turnstiles > 1010.1 Doors > 1010.1.9 Door Operations > 1010.1.9.4 Bolt Locks
Help Contact Us Privacy Terms
Code Compare
Code Compare
Highlight differences between any two building codes.
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
TRY FREE FOR TWO WEEKS VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL LEARN MORE