• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects General Contractor Building Official & Plans Examiner Inspectors Owner Subcontractors Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

23-471 Beyond One Hundred Feet of a Street Line

NYC Zoning Resolution > II Residence District Regulations > 3 - Residential Bulk Regulations in Residence Districts > 23-40 Yard Regulations > 23-47 Minimum Required Rear Yards > 23-471 Beyond One Hundred Feet of a Street Line
JUMP TO FULL CODE CHAPTER

R1 R2 R3 R4 R5 R6 R7 R8 R9 R10

In all districts, as indicated, for interior or through lot portions of corner lots, and for zoning lots bounded by two or more streets that are neither corner lots nor through lots, the portion of a side lot line beyond 100 feet of the street line that it intersects shall be considered a rear lot line and the following rules shall apply along such rear lot line :

(a)        In all districts, a rear yard with a minimum depth of 30 feet shall be provided where such rear lot line coincides with a rear lot line of an adjoining zoning lot.

CORNER LOT

(23-471a)

(b)        In R1 through R5 Districts, a rear yard with a minimum depth of eight feet shall be provided where such rear lot line coincides with a side lot line of an adjoining zoning lot.

ZONING LOT BOUNDED BY TWO OR MORE STREETS

(NEITHER A CORNER LOT NOR A THROUGH LOT)

(23-471b)

(c)        In R6 through R10 Districts, no rear yard shall be required where such rear lot line coincides with a side lot line of an adjoining zoning lot.

Regulations Applying in Special Situations

Side Yards

Related Code Sections


§28-112.2 Administration, Schedule of Permit Fees
: Illuminated sign projecting beyond street line having thirty square feet or less on one side. Filing fee calculated as for respective building alteration ...
NYC General Admin. Provisions 2008 > 1 Administration > 112 Fees > §28-112.2 Schedule of Permit Fees
Article 3 Administration [PDF] (page 25)
hundred thirty-eight, beyond the building line so as to encroach upon a public street or public space, except as otherwise specifically provided ...
NYC 1938 Code [PDF] > 3 Administration
Article 3 Administration [PDF] (page 26)
, shall not extend within two feet of the curb line nor more than two and one-half feet beyond either side of an entrance. The aggregate length of all ...
NYC 1938 Code [PDF] > 3 Administration
3202.2.1 Encroachments Into the Public Right-Of-Way, Encroachments Subject to the Area Limitations
(457 mm). Entrance steps that project beyond the street line shall be guarded at each end by railings or check pieces at least 3 feet (914 mm) high ...
NYC Building Code 2008 > 32 Encroachments Into the Public Right-Of-Way > 3202 Encroachments > 3202.2 Encroachments Above Grade > 3202.2.1 Encroachments Subject to the Area Limitations
§28-112.2 Administration, Schedule of Permit Fees
to erect, install or alter sign: Illuminated sign projecting beyond street line having thirty square feet or less on one side. Filing fee calculated ...
NYC General Admin. Provisions 2014 > 1 Administration > 112 Fees > §28-112.2 Schedule of Permit Fees
Help Contact Us Privacy Terms
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
Code Compare
Code Compare
Highlight differences between any two building codes.
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
TRY FREE FOR TWO WEEKS VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL LEARN MORE