5.3.1.4.2 Between Car and Landing Sill
Go To Full Code Chapter
The clearance between the car platform sill and the landing sill shall be not less than 13 mm (0.5 in.) nor more than 32 mm (1.25 in.).
Related Code Sections
2.5.1.4 Electric Elevators, Between Car and Landing Sills
The clearance between the car platform sill and the hoistway edge of any landing sill, or the hoistway side of any vertically sliding counterweighted ...
2.5.1.4 Electric Elevators, Between Car and Landing Sills
The clearance between the car platform sill and the hoistway edge of any landing sill, or the hoistway side of any vertically sliding counterweighted ...
5.3.1.4.2 Special Application Elevators, Between Car and Landing Sill
The clearance between the car platform sill and the landing sill shall be not less than 13 mm (0.5 in.) nor more than 32 mm (1.25 in.) ...
5.3.1.4.2 Special Application Elevators, Between Car and Landing Sill
The clearance between the car platform sill and the landing sill shall be not less than 13 mm (0.5 in.) nor more than 32 mm (1.25 in.) ...
5.4.2.5 Special Application Elevators, Horizontal Clearance Between Car and Landing Sills
The horizontal clearance between the car and landing sills shall conform to 5.3.1.4.2 ...