// CODE SNIPPET
5.106.1.2 Best Management Practices (BMP's)
JUMP TO FULL CODE CHAPTER
Prevent
the loss of soil through wind or water erosion by implementing
an effective combination of erosion and sediment
control and good housekeeping BMP's.
Soil loss BMP's that should be considered for implementation as appropriate for each project include, but are not limited to, the following:
- Scheduling construction activity during dry weather, when possible.
- Preservation of natural features, vegetation, soil, and buffers around surface waters.
- Drainage swales or lined ditches to control stormwater flow.
- Mulching or hydroseeding to stabilize disturbed soils.
- Erosion control to protect slopes.
- Protection of storm drain inlets (gravel bags or catch basin inserts).
- Perimeter sediment control (perimeter silt fence, fiber rolls).
- Sediment trap or sediment basin to retain sediment on site.
- Stabilized construction exits.
- Wind erosion control.
- Other soil loss BMP's acceptable to the enforcing agency.
Good housekeeping BMP's to manage construction equipment, materials, non-stormwater discharges, and wastes that should be considered for implementation as appropriate for each project include, but are not limited to, the following:
- Dewatering activities.
- Material handling and waste management.
- Building materials stockpile management.
- Management of washout areas (concrete, paints, stucco, etc.).
- Control of vehicle/equipment fueling to contractor's staging area.
- Vehicle and equipment cleaning performed off site.
- Spill prevention and control.
- Other housekeeping BMP's acceptable to the enforcing agency.
Related Code Sections
5.106.1.2 Nonresidential Mandatory Measures, Best Management Practices (BMP's)
BMP's acceptable to the
enforcing agency. Good housekeeping BMP's to manage construction
equipment, materials, non-stormwater discharges ...
Los Angeles Green Building Code > 5 Nonresidential Mandatory Measures > 5.106 Site Development > 5.106.1 Stormwater Pollution Prevention for Projects That Disturb Less Than One Acre of Land > 5.106.1.2 Best Management Practices (BMP's)
5.106.1.2 Nonresidential Mandatory Measures, Best Management Practices (BMP's)
BMP's acceptable to the
enforcing agency. Good housekeeping BMP's to manage construction
equipment, materials, non-stormwater discharges ...
Los Angeles Green Building Code > 5 Nonresidential Mandatory Measures > 5.106 Site Development > 5.106.1 Stormwater Pollution Prevention for Projects That Disturb Less Than One Acre of Land > 5.106.1.2 Best Management Practices (BMP's)
A5.106.3 Nonresidential Voluntary Measures, Low Impact Development (LID)
the application of LID
strategies. Employ at least two of the following methods or
other best management practices to allow rainwater to soak ...
Los Angeles Green Building Code > A5 Nonresidential Voluntary Measures > A5.106 Site Development > A5.106.3 Low Impact Development (LID)
A5.106.3 Nonresidential Voluntary Measures, Low Impact Development (LID)
the application of LID
strategies. Employ at least two of the following methods or
other best management practices to allow rainwater to soak ...
Los Angeles Green Building Code > A5 Nonresidential Voluntary Measures > A5.106 Site Development > A5.106.3 Low Impact Development (LID)
1251.4 Interior Environment, Practice Management
Veterinary facilities shall maintain a sanitary environment to avoid sources and transmission of infection. This is to include the proper routine ...
Los Angeles Building Code > 12 Interior Environment > 1251 [CA] Veterinary Facilities > 1251.4 Practice Management