1926.307(l)(1) Belt Shifters
JUMP TO FULL CODE CHAPTER
Tight and loose pulleys on all new installations made on or after August 31, 1971, shall be equipped with a permanent belt shifter provided with mechanical means to prevent belt from creeping from loose to tight pulley. It is recommended that old installations be changed to conform to this rule.
Belt shifter and clutch handles shall be rounded and be located as far as possible from danger of accidental contact, but within easy reach of the operator. Where belt shifter are not directly located over a machine or bench, the handles shall be cut off 6 ft. 6 in. (1.976 m) above floor level.
Related Code Sections
1926.307(l)(1) Tools - Hand and Power, Belt Shifters
Tight and loose pulleys on all new installations made on or after August 31, 1971, shall be equipped with a permanent belt shifter provided ...
OSHA 1926 Construction > I Tools - Hand and Power > 1926.307 Mechanical Power-Transmission Apparatus > 1926.307(l) Belt Shifters, Clutches, Shippers, Poles, Perches, and Fasteners > 1926.307(l)(1) Belt Shifters
1926.307(l)(3) Tools - Hand and Power, Belt Perches
Where loose pulleys or idlers are not practicable, belt perches in form of brackets, rollers, etc., shall be used to keep idle belts away from ...
OSHA 1926 Construction > I Tools - Hand and Power > 1926.307 Mechanical Power-Transmission Apparatus > 1926.307(l) Belt Shifters, Clutches, Shippers, Poles, Perches, and Fasteners > 1926.307(l)(3) Belt Perches
1926.307(l)(4) Tools - Hand and Power, Belt Fasteners
Belts which of necessity must be shifted by hand and belts within 7 feet (2.128 m) of the floor or working platform which are not guarded ...
OSHA 1926 Construction > I Tools - Hand and Power > 1926.307 Mechanical Power-Transmission Apparatus > 1926.307(l) Belt Shifters, Clutches, Shippers, Poles, Perches, and Fasteners > 1926.307(l)(4) Belt Fasteners
1926.307(l)(2) Tools - Hand and Power, Belt Shippers and Shipper Poles
The use of belt poles as substitutes for mechanical shifter is not recommended ...
OSHA 1926 Construction > I Tools - Hand and Power > 1926.307 Mechanical Power-Transmission Apparatus > 1926.307(l) Belt Shifters, Clutches, Shippers, Poles, Perches, and Fasteners > 1926.307(l)(2) Belt Shippers and Shipper Poles
1926.307(e)(5)(ii) Tools - Hand and Power,
If the belt is of the endless type or laced with rawhide laces, and a belt shifter is not desired, the belt will be considered guarded if the nip ...
OSHA 1926 Construction > I Tools - Hand and Power > 1926.307 Mechanical Power-Transmission Apparatus > 1926.307(e) Belt, Rope, and Chain Drives > 1926.307(e)(5) Cone-Pulley Belts > 1926.307(e)(5)(ii)