• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects General Contractor Building Official & Plans Examiner Inspectors Owner Subcontractors Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Suggested code sections
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

R406.3.2 Below-Grade Moisture Barrier

Los Angeles Residential Code > 4 Foundations > R406 Foundation Waterproofing and Dampproofing > R406.3 Dampproofing for Wood Foundations > R406.3.2 Below-Grade Moisture Barrier
JUMP TO FULL CODE CHAPTER
A 6-mil-thick (0.15 mm) polyethylene film shall be applied over the below-grade portion of exterior foundation walls prior to backfilling. Joints in the polyethylene film shall be lapped 6 inches (152 mm) and sealed with adhesive. The top edge of the polyethylene film shall be bonded to the sheathing to form a seal. Film areas at grade level shall be protected from mechanical damage and exposure by a pressure-preservative treated lumber or plywood strip attached to the wall several inches above finished grade level and extending approximately 9 inches (229 mm) below grade. The joint between the strip and the wall shall be caulked full length prior to fastening the strip to the wall. Where approved, other coverings appropriate to the architectural treatment shall be permitted to be used. The polyethylene film shall extend down to the bottom of the wood footing plate but shall not overlap or extend into the gravel or crushed stone footing.

Related Code Sections


R406.3.2 Foundations, Below-Grade Moisture Barrier
A 6-mil-thick (0.15 mm) polyethylene film shall be applied over the below-grade portion of exterior foundation walls prior to backfilling. Joints ...
Los Angeles Residential Code > 4 Foundations > R406 Foundation Waterproofing and Dampproofing > R406.3 Dampproofing for Wood Foundations > R406.3.2 Below-Grade Moisture Barrier
R406.3.2 Foundations, Below-Grade Moisture Barrier
A 6-mil-thick (0.15 mm) polyethylene film shall be applied over the below- grade portion of exterior foundation walls prior to backfilling. Joints ...
Los Angeles Residential Code > 4 Foundations > R406 Foundation Waterproofing and Dampproofing > R406.3 Dampproofing for Wood Foundations > R406.3.2 Below-Grade Moisture Barrier
AS105.6 Strawbale Construction, Moisture Control
bale walls and elements. Where the water-resistant barrier is below the finish material, it shall be sloped not less than 1 unit vertical in 12 units ...
Los Angeles Residential Code > S Strawbale Construction > AS105 Strawbale Walls—General > AS105.6 Moisture Control
R504.2.2 Floors, Moisture Barrier
Polyethylene sheeting of minimum 6-mil (0.15 mm) thickness shall be placed over the granular base. Joints shall be lapped 6 inches (152 mm) and left ...
Los Angeles Residential Code > 5 Floors > R504 Pressure Preservative-Treated Wood Floors (On Ground) > R504.2 Site Preparation > R504.2.2 Moisture Barrier
R504.2.2 Floors, Moisture Barrier
Polyethylene sheeting of minimum 6-mil (0.15 mm) thickness shall be placed over the granular base. Joints shall be lapped 6 inches (152 mm) and left ...
Los Angeles Residential Code > 5 Floors > R504 Pressure Preservative-Treated Wood Floors (On Ground) > R504.2 Site Preparation > R504.2.2 Moisture Barrier
Help Contact Us Privacy Terms
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
View thousands of relevant UL Certified products and assemblies that help achieve code compliance
View thousands of relevant UL Certified products and assemblies that help achieve code compliance
Access to UL product and system certification information.
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
Code Compare
Code Compare
Highlight differences between any two building codes.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
TRY FREE FOR TWO WEEKS VISIT PRICING
Join the waitlist
We are looking to gauge the level of interest in linking UL product and system certification information alongside related code sections.

Let us know your email and we’ll ping you once it’s ready! Learn more.

Thank you for your interest!

If you’re open to it, we would love to jump on the phone to make sure we’re building this in the best way possible for your workflow. Any insight or advice would be greatly appreciated. We’ve sent you an email with a calendar link to book at time with us.


Cancel
Get Early Access
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL LEARN MORE