• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects General Contractor Building Official & Plans Examiner Inspectors Owner Subcontractors Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Suggested code sections
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

1910.1029(f)(1)(iii) Beehive Ovens

OSHA 1910 General Industry > Z Toxic and Hazardous Substances > 1910.1029 Coke Oven Emissions > 1910.1029(f) Methods of Compliance > 1910.1029(f)(1) Priority of Compliance Methods > 1910.1029(f)(1)(iii) Beehive Ovens
JUMP TO FULL CODE CHAPTER

1910.1029(f)(1)(iii)(a)

The employer shall institute engineering and work practice controls on all beehive ovens at the earliest possible time to reduce and maintain employee exposures at or below the permissible exposure limit, except to the extent that the employer can establish that such controls are not feasible. In determining the earliest possible time for institution of engineering and work practice controls, the requirement, effective August 27, 1971, to implement feasible administrative or engineering controls to reduce exposures to coal tar pitch volatiles, shall be considered. Wherever the engineering and work practice controls which can be instituted are not sufficient to reduce employee exposures to or below the permissible exposure limit, the employer shall nonetheless use them to reduce exposures to the lowest level achievable by these controls and shall supplement them by the use of respiratory protection which complies with the requirements of paragraph (g) of this section.

1910.1029(f)(1)(iii)(b)

If, after implementing all engineering and work practice controls required by paragraph (f)(1)(iii)(a) of this section, employee exposures still exceed the permissible exposure limit, the employer shall implement any other engineering and work practice controls necessary to reduce exposures to or below the permissible exposure limit except to the extent that the employer can establish that such controls are not feasible. Whenever the engineering and work practice controls which can be instituted are not sufficient to reduce employee exposures to or below the permissible exposure limit, the employer shall nonetheless use them to reduce exposures to the lowest level achievable by these controls and shall supplement them by the use of respiratory protection which complies with the requirements of paragraph (g) of this section.

Related Code Sections


1910.1029(f)(1)(iii) Toxic and Hazardous Substances, Beehive Ovens
The employer shall institute engineering and work practice controls on all beehive ovens at the earliest possible time to reduce and maintain ...
OSHA 1910 General Industry > Z Toxic and Hazardous Substances > 1910.1029 Coke Oven Emissions > 1910.1029(f) Methods of Compliance > 1910.1029(f)(1) Priority of Compliance Methods > 1910.1029(f)(1)(iii) Beehive Ovens
Appendix A Toxic and Hazardous Substances, Coke Oven Emissions Substance Information Sheet
machinery, cokeside and its machinery, and the battery ends; the screening station; and the wharf; and the beehive ovens and their machinery ...
OSHA 1910 General Industry > Z Toxic and Hazardous Substances > 1910.1029 Coke Oven Emissions > A Coke Oven Emissions Substance Information Sheet
1910.1029 Toxic and Hazardous Substances, Coke Oven Emissions
paragraph (n) of this section. Beehive oven means a coke oven in which the products of carbonization other than coke are not recovered ...
OSHA 1910 General Industry > Z Toxic and Hazardous Substances > 1910.1029 Coke Oven Emissions
1910.1029(f) Toxic and Hazardous Substances, Methods of Compliance
institute engineering and work practice controls on all beehive ovens at the earliest possible time to reduce and maintain employee exposures at or below ...
OSHA 1910 General Industry > Z Toxic and Hazardous Substances > 1910.1029 Coke Oven Emissions > 1910.1029(f) Methods of Compliance
1910.263(l) Special Industries, Ovens
] Ovens shall be located so that possible fire or explosion will not expose groups of persons to possible injury. For this reason ovens shall ...
OSHA 1910 General Industry > R Special Industries > 1910.263 Bakery Equipment > 1910.263(l) Ovens
Help Contact Us Privacy Terms
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
Code Compare
Code Compare
Highlight differences between any two building codes.
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
TRY FREE FOR TWO WEEKS VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL LEARN MORE