1802.5.1 Bedrock Support
JUMP TO FULL CODE CHAPTER
Where the foundation design relies on rock to support footings, piles or caisson sockets, a sufficient number of rock corings shall extend at least 10 feet (3048 mm) below the lowest level of bearing to provide assurance of the rock soundness. Where foundations are to rest on bedrock and such rock is exposed over a part or all of the area of the building, borings are not required in those areas where rock is exposed, provided the following requirements are met:
- The presence of defects or the inclination of bedding planes in the rock are of such size and location so as not to affect stability of the foundation.
- The foundation is not designed for bearing pressures exceeding those permitted in Table 1802.3.
Related Code Sections
1802.5.1 Soils and Foundations, Bedrock Support
Where the foundation design relies on rock to support footings, piles or caisson sockets, a sufficient number of rock corings shall extend at least ...
NYC Building Code 2008 > 18 Soils and Foundations > 1802 Foundation and Soils Investigations > 1802.5 Soil and Rock Sampling > 1802.5.1 Bedrock Support
1802.5.1 Soils and Foundations, Bedrock Support
Where the foundation design relies on rock to support footings, piles or caisson sockets, a sufficient number of rock corings shall extend at least ...
NYC Building Code 2014 > 18 Soils and Foundations > 1802 Geotechnical Investigations and Material Classifications > 1802.5 Soil and Rock Sampling > 1802.5.1 Bedrock Support
1810.7.1 Soils and Foundations, Construction
Caisson piles shall consist of a shaft section of concrete-filled pipe extending to bedrock with an uncased socket drilled into the bedrock ...
NYC Building Code 2008 > 18 Soils and Foundations > 1810 Cast-In-Place Concrete Pile Foundations > 1810.7 Caisson Piles > 1810.7.1 Construction
1810.7.1 Soils and Foundations, Construction
Caisson piles shall consist of a shaft section of concrete or grout-filled pipe, extending to bedrock, with an uncased socket drilled into bedrock ...
NYC Building Code 2014 > 18 Soils and Foundations > 1810 Cast-In-Place Concrete Piles > 1810.7 Caisson Piles > 1810.7.1 Construction
1813.2 Soils and Foundations, Site-Specific Analyses
response analysis is conducted, bedrock acceleration time histories and a shear wave velocity profile based on in-situ measurements may be utilized. These ...
NYC Building Code 2008 > 18 Soils and Foundations > 1813 Liquefaction Analysis > 1813.2 Site-Specific Analyses