713.2 Bedpan Washers and Clinical Sinks
JUMP TO FULL CODE CHAPTER
Bedpan washers and clinical sinks shall connect to the drainage and vent system in accordance with the requirements for a water closet. Bedpan washers shall also connect to a local vent.
Related Code Sections
713.2 Sanitary Drainage, Bedpan Washers and Clinical Sinks
Bedpan washers and clinical sinks shall connect to the drainage and vent system in accordance with the requirements for a water closet. Bedpan ...
Plumbing Code 2015 of New York State > 7 Sanitary Drainage > 713 Health Care Plumbing > 713.2 Bedpan Washers and Clinical Sinks
713.2 Sanitary Drainage, Bedpan Washers and Clinical Sinks
Bedpan washers and clinical sinks shall connect to the drainage and vent system in accordance with the requirements for a water closet. Bedpan ...
2010 Plumbing Code of NY > 7 Sanitary Drainage > 713 Health Care Plumbing > 713.2 Bedpan Washers and Clinical Sinks
422.6 Fixtures, Faucets and Fixture Fittings, Clinical Sink
A clinical sink shall have an integral trap in which the upper portion of a visible trap seal provides a water surface. The fixture shall be designed ...
Plumbing Code 2015 of New York State > 4 Fixtures, Faucets and Fixture Fittings > 422 Health Care Fixtures and Equipment > 422.6 Clinical Sink
422.6 Fixtures, Clinical Sink
A clinical sink shall have an integral trap in which the upper portion of a visible trap seal provides a water surface. The fixture shall be designed ...
2010 Plumbing Code of NY > 4 Fixtures > 422 Health Care Fixtures and Equipment > 422.6 Clinical Sink
422.7 Fixtures, Prohibited Usage of Clinical Sinks and Service Sinks
A clinical sink serving a soiled utility room shall not be considered as a substitute for, or be utilized as, a service sink. A service sink shall ...
2010 Plumbing Code of NY > 4 Fixtures > 422 Health Care Fixtures and Equipment > 422.7 Prohibited Usage of Clinical Sinks and Service Sinks