• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects General Contractor Building Official & Plans Examiner Inspectors Owner Subcontractors Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Suggested code sections
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

3306.9.10.1 Bearing Partitions and Headers

NYC Building Code 2014 > 33 Safeguards During Construction or Demolition > 3306 Demolition > 3306.9 Safeguards > 3306.9.10 Floors > 3306.9.10.1 Bearing Partitions and Headers
JUMP TO FULL CODE CHAPTER
No bearing partition shall be removed from any floor until the floor framing system on the floor above has been removed and lowered. All header beams and headers at stair openings and chimneys shall be carefully examined and, where required, shall be shored from the cellar floor through successive floors. All operations shall be continually monitored by a qualified person designated by the permit holder as the work progresses to detect any hazards that may develop.

Related Code Sections


3306.9.10.1 Safeguards During Construction or Demolition, Bearing Partitions and Headers
No bearing partition shall be removed from any floor until the floor framing system on the floor above has been removed and lowered. All header beams ...
NYC Building Code 2014 > 33 Safeguards During Construction or Demolition > 3306 Demolition > 3306.9 Safeguards > 3306.9.10 Floors > 3306.9.10.1 Bearing Partitions and Headers
2308.9.6 Wood, Openings in Interior Bearing Partitions
Headers shall be provided over each opening in interior bearing partitions as required in Section 2308.9.5. The spans in Table 2308.9.6 are permitted ...
NYC Building Code 2008 > 23 Wood > 2308 Conventional Light-Frame Construction > 2308.9 Wall Framing > 2308.9.6 Openings in Interior Bearing Partitions
2308.8.3 Wood, Framing Around Openings
of header joists more than 6 feet (1829 mm) long shall be supported by framing anchors or joist hangers unless bearing on a beam, partition or wall ...
NYC Building Code 2014 > 23 Wood > 2308 Conventional Light-Frame Construction > 2308.8 Floor Joists > 2308.8.3 Framing Around Openings
2308.10.4.3 Wood, Framing Around Openings
ends of header rafters more than 6 feet (1829 mm) long shall be supported by framing anchors or rafter hangers unless bearing on a beam, partition ...
NYC Building Code 2014 > 23 Wood > 2308 Conventional Light-Frame Construction > 2308.10 Roof and Ceiling Framing > 2308.10.4 Ceiling Joist and Rafter Framing > 2308.10.4.3 Framing Around Openings
3306.9.10 Safeguards During Construction or Demolition, Floors
No bearing partition shall be removed from any floor until the floor framing system on the floor above has been removed and lowered. All header beams ...
NYC Building Code 2008 > 33 Safeguards During Construction or Demolition > 3306 Demolition > 3306.9 Full Demolition and Partial Demolition Operations > 3306.9.10 Floors
Help Contact Us Privacy Terms
Code Compare
Code Compare
Highlight differences between any two building codes.
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
TRY FREE FOR TWO WEEKS VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL LEARN MORE