// CODE SNIPPET
2104.9.1 Bearing Details
JUMP TO FULL CODE CHAPTER
Concentrated loads shall be supported upon construction of solid masonry, concrete, or masonry of hollow units with cells filled with mortar, grout, or concrete. In addition, construction supporting concentrated loads shall be of sufficient height to distribute safely the loads to the wall or column, or other adequate provisions shall be made to distribute the loads.
Solid construction for support under joists shall be at least 21/4 inches (57 mm) in height, and joists supported on such construction shall extend into the masonry at least 3 inches (76 mm).
Solid construction for support under beams, girders, or other concentrated loads shall be at least 4 inches (102 mm) in height, and the bearing of beams shall extend into the masonry at least 4 inches (102 mm).
Related Code Sections
2104.9.1 Masonry, Bearing Details
, and the bearing of beams shall extend into the masonry at least 4 inches (102 mm ...
NYC Building Code 2014 > 21 Masonry > 2104 Construction > 2104.9 Floor and Roof Anchorage > 2104.9.1 Bearing Details
2109.7.3.1.1 Masonry, Bearing Details
Concentrated loads shall be supported upon construction of solid masonry, concrete, or masonry of hollow units with cells filled with mortar, grout ...
NYC Building Code 2008 > 21 Masonry > 2109 Empirical Design of Masonry > 2109.7 Anchorage > 2109.7.3 Floor and Roof Anchorage > 2109.7.3.1 Wood Floor Joists > 2109.7.3.1.1 Bearing Details
1808.5.7 Soils and Foundations, Pile Location Plan
of such piles. Detailed records for individual piles shall bear an identification corresponding to that shown on the plan ...
NYC Building Code 2014 > 18 Soils and Foundations > 1808 Deep Foundations > 1808.5 Installation > 1808.5.7 Pile Location Plan
Reference Standard 10 Structural Work [PDF] (page 18)
be provided with adequate means for distributing the load at the top of the pier. 10.8 - Bearing details - Concentrated loads shall be supported upon ...
§27-688 Foundations, Administrative Requirements
to installation of such piles. All detailed records for individual piles shall bear an identification corresponding to that shown on the plan. A copy ...
NYC 1968 Code (Vol I) > 11 Foundations > 7 Pile Foundations-General Requirements > §27-688 Administrative Requirements