2212A.2.2 Beam-To-Column Strength Ratio
JUMP TO FULL CODE CHAPTER
At each moment-resisting connection the following shall apply:
(Equation 22A-1)
where:
Fybi | = | The specified yield stress of beam "i." |
Fycj | = | The specified yield stress of column "j." |
Sbi | = | The flexural section modulus of each beam "i" that is moment connected to the column "j" at the connection. |
Scj | = | The flexural section modulus of each column "j" that is moment connected to the beam "i" at the connection. |
Exceptions:
Related Code Sections
2212A.2.2 Steel, Beam-To-Column Strength Ratio
Beam-to-column strength ratios less than 1.4 are allowed if proven to be acceptable by analysis or testing ...
Los Angeles Building Code > 22A Steel > 2212A [DSA-SS] Light Modular Steel Moment Frames for Public Elementary and Secondary Schools, and Community Colleges > 2212A.2 Seismic Requirements > 2212A.2.2 Beam-To-Column Strength Ratio
722.5.1.1.3 Fire and Smoke Protection Features, Weight-To-Perimeter Ratio
often used as columns. For different fire-resistant protection profiles or column cross sections, the weight-to-heated-perimeter ratios ( W/D ) shall ...
Los Angeles Building Code > 7 Fire and Smoke Protection Features > 722 Calculated Fire Resistance > 722.5 Steel Assemblies > 722.5.1 Structural Steel Columns > 722.5.1.1 General > 722.5.1.1.3 Weight-To-Perimeter Ratio
722.5.1.1.3 Fire and Smoke Protection Features, Weight-To-Perimeter Ratio
often used as columns. For different fire-resistant protection profiles or column cross sections, the weight-to-heated-perimeter ratios (W/D) shall ...
Los Angeles Building Code > 7 Fire and Smoke Protection Features > 722 Calculated Fire Resistance > 722.5 Steel Assemblies > 722.5.1 Structural Steel Columns > 722.5.1.1 General > 722.5.1.1.3 Weight-To-Perimeter Ratio
Section II Guidelines on Fire Ratings of Archaic Materials and Assemblies, Columns
TABLE 2.1.1 REINFORCED CONCRETE COLUMNS MINIMUM DIMENSION 0" TO LESS THAN 6"
ITEM CODE
MINIMUM DIMENSION
CONSTRUCTION DETAILS ...
Los Angeles Existing Building Code > A Guidelines on Fire Ratings of Archaic Materials and Assemblies > II Columns
1615.3.2.2 Structural Design, Beams
End connections of all beams and girders shall have a minimum nominal axial tensile strength equal to the required vertical shear strength ...
Los Angeles Building Code > 16 Structural Design > 1615 Structural Integrity > 1615.3 Frame Structures > 1615.3.2 Structural Steel, Open Web Steel Joist or Joist Girder, or Composite Steel and Concrete Frame Structures > 1615.3.2.2 Beams