610.4 Beach Entry, Zero-Depth Entry, and Sloping Entries
JUMP TO FULL CODE CHAPTER
The shallow end for beach entries and sloping entries shall be in accordance with Sections 610.4.1 through 610.4.4 or the regulations of the local jurisdiction.
The slope of sloping entries used as a pool entry shall not exceed 1 unit vertical in 12 units horizontal (8.3-percent slope).
Where benches are used in conjunction with sloping entries, the vertical riser height shall not exceed 12 inches (305 mm).
Where steps are used in conjunction with sloping entries, all of the requirements of Section 610.5 shall apply.
Beach and sloping entry walking surfaces at water depths up to 18 inches (457 mm) shall be slip resistant.
Related Code Sections
610.4 Aquatic Recreation Facilities, Beach Entry, Zero-Depth Entry, and Sloping Entries
Beach and sloping entry walking surfaces at water depths up to 18 inches (457 mm) shall be slip resistant ...
Section 3109 of the 2015 WSBC > 6 Aquatic Recreation Facilities > 610 Special Features > 610.4 Beach Entry, Zero-Depth Entry, and Sloping Entries
809.6 Permanent Inground Residential Swimming Pools, Beach and Sloping Entries
The slope of beach and sloping entries used as a pool entrance shall not exceed 1 unit vertical in 7 units horizontal (14-percent slope) ...
Section 3109 of the 2015 WSBC > 8 Permanent Inground Residential Swimming Pools > 809 Special Features > 809.6 Beach and Sloping Entries
1109.3 Recreational Facilities, Sloped Entries
FIGURE 1109.3.2 SLOPED ENTRY SUBMERGED DEPTH ...
Accessible and Usable Buildings and Facilities 2009 of Washington > 11 Recreational Facilities > 1109 Swimming Pools, Wading Pools, Hot Tubs and Spas > 1109.3 Sloped Entries
411.1 Public Swimming Pools, Entry and Exit
A means of entry and exit shall be provided in shallow areas of pools and shall consist of pool stairs, a ramp or a beach ...
Section 3109 of the 2015 WSBC > 4 Public Swimming Pools > 411 Special Features > 411.1 Entry and Exit
411.3 Public Swimming Pools, Shallow End Detail for Beach and Sloping Entries
Beach and sloping entry surfaces shall be of slip-resistant materials ...
Section 3109 of the 2015 WSBC > 4 Public Swimming Pools > 411 Special Features > 411.3 Shallow End Detail for Beach and Sloping Entries