R307.2 Bathtub and Shower Spaces
JUMP TO FULL CODE CHAPTER
Bathtub and shower floors and walls above bathtubs with installed shower heads and in shower compartments shall be finished with a nonabsorbent surface. Such wall surfaces shall extend to a height of not less than 6 feet (1829 mm) above the floor.
Related Code Sections
(C) Equipment for General Use, Bathtub and Shower Space
Receptacles shall not be installed within or directly over a bathtub or shower stall ...
National Electrical Code 2017 of Utah > 4 Equipment for General Use > 406 Receptacles, Cord Connectors, and Attachment Plugs (Caps) > 406.9 Receptacles in Damp or Wet Locations > (C) Bathtub and Shower Space
E4002.11 Devices and Luminaires, Bathtub and Shower Space
A receptacle shall not be installed within or directly over a bathtub or shower stall. [406.9(C)] ...
Residential Code 2015 of Utah > 40 Devices and Luminaires > E4002 Receptacles > E4002.11 Bathtub and Shower Space
P2710.1 Plumbing Fixtures, Bathtub and Shower Spaces
Walls in shower compartments and walls above bathtubs that have a wall-mounted showerhead shall be finished in accordance with Section R307.2 ...
Residential Code 2015 of Utah > 27 Plumbing Fixtures > P2710 Shower Walls > P2710.1 Bathtub and Shower Spaces
R307.2 Building Planning, Bathtub and Shower Spaces
Bathtub and shower floors and walls above bathtubs with installed shower heads and in shower compartments shall be finished with a nonabsorbent ...
Residential Code 2015 of Utah > 3 Building Planning > R307 Toilet, Bath and Shower Spaces > R307.2 Bathtub and Shower Spaces
(F) Special Occupancies, Receptacle Outlets Not Permitted
or shower space. A receptacle shall not be installed in a face-up position in any countertop. Receptacle outlets shall not be installed above ...
National Electrical Code 2017 of Utah > 5 Special Occupancies > 550 Mobile Homes, Manufactured Homes, and Mobile Home Parks > 550.13 Receptacle Outlets > (F) Receptacle Outlets Not Permitted