// CODE SNIPPET
P102.9.1 Bathtub
JUMP TO FULL CODE CHAPTER
Bathtubs, including those within a toilet and bathing room accessed through a private office by a single occupant, shall comply with Section 607 of ICC A117.1. Lavatories complying with Section P102.6 shall be permitted in the clearance required by Section 607.2 of ICC A117.1. Bathtub seats shall not be required.
Exception: Where a hand shower in compliance with Section 607.6 of ICC A117.1 is not provided, the owner shall provide such a hand shower at the time a person with physical disabilities takes occupancy of the unit, or within 10 days of the date the request is made by a person with physical disabilities, whichever is later, at the owner's expense.
Exception: Where a hand shower in compliance with Section 607.6 of ICC A117.1 is not provided, the owner shall provide such a hand shower at the time a person with physical disabilities takes occupancy of the unit, or within 10 days of the date the request is made by a person with physical disabilities, whichever is later, at the owner's expense.
Grab bars for bathtubs, including those within a toilet and bathing room accessed through a private office by a single occupant, shall comply with Section 609 of ICC A117.1 and shall be provided in accordance with Section 607.4 of ICC A117.1.
Exception: Grab bars are not required to be installed where reinforcement for such grab bars is installed and located to permit future installation of grab bars complying with Section P102.9.1.1.
Exception: Grab bars are not required to be installed where reinforcement for such grab bars is installed and located to permit future installation of grab bars complying with Section P102.9.1.1.
Related Code Sections
1003.11.2.5.1 Dwelling Units and Sleeping Units, Bathtub
Bathtubs shall comply with Section 607. EXCEPTIONS: The removable in-tub seat required by Section 607.3 is not required. Counter tops ...
Accessible and Usable Buildings and Facilities 2009 of New York City > 10 Dwelling Units and Sleeping Units > 1003 Type A Units > 1003.11 Toilet and Bathing Facilities > 1003.11.2 General > 1003.11.2.5 Bathing Fixtures > 1003.11.2.5.1 Bathtub
1004.11.3.2.3.1 Dwelling Units and Sleeping Units, Bathtub
A clearance 48 inches (1220 mm) minimum in length measured perpendicular from the control end of the bathtub, and 30 inches (760 mm) minimum in width ...
Accessible and Usable Buildings and Facilities 2009 of New York City > 10 Dwelling Units and Sleeping Units > 1004 Type B Units > 1004.11 Toilet and Bathing Facilities > 1004.11.3 Toilet and Bathing Areas > 1004.11.3.2 Option B > 1004.11.3.2.3 Bathing Fixtures > 1004.11.3.2.3.1 Bathtub
1107.2.2.8.1 Accessibility, Bathtubs
Bathtubs shall comply with Section 607 of ICC A117.1.
Lavatories complying with Section 1107.2.2.5 of this code shall be permitted in the
clearance ...
NYC Building Code 2022 > 11 Accessibility > 1107 Dwelling Units and Sleeping Units > 1107.2 Design > 1107.2.2 Type B+NYC Unit Toilet and Bathing Rooms > 1107.2.2.8 Bathing Facilities > 1107.2.2.8.1 Bathtubs
Section 407 Fixtures, Faucets and Fixture Fittings, Bathtubs
Bathtubs shall conform to ANSI Z124.1, ASME A112.19.1M, ASME A112.19.4M, ASME A112.19.9M, CSA B45.2, CSA B45.3 or CSA B45.5 ...
Section 407 Fixtures, Faucets and Fixture Fittings, Bathtubs
Bathtubs shall conform to ANSI Z124.1, ASME A112.19.1M, ASME A112.19.4M, ASME A112.19.9M, CSA B45.2, CSA B45.3 or CSA B45.5 ...