// CODE SNIPPET
E3902.1 Bathroom Receptacles
JUMP TO FULL CODE CHAPTER
125-volt, single-phase, 15- and 20-ampere receptacles installed in bathrooms shall have ground-fault circuit-interrupter protection for personnel. [210.8(A)(1)]
Related Code Sections
E3902.1 Power and Lighting Distribution, Bathroom Receptacles
125-volt, single-phase, 15- and 20-ampere receptacles installed in bathrooms shall have ground-fault circuit-interrupter protection for personnel ...
Residential Code 2018 of Kansas > 39 Power and Lighting Distribution > E3902 Ground-Fault and Arc-Fault Circuit-Interrupter Protection > E3902.1 Bathroom Receptacles
(E) Special Occupancies, Bathrooms
Bathroom receptacle outlets shall be supplied by at least one 20-ampere branch circuit. Such circuits shall have no outlets other than as provided ...
National Electrical Code 2017 of Kansas > 5 Special Occupancies > 550 Mobile Homes, Manufactured Homes, and Mobile Home Parks > 550.12 Branch Circuits > (E) Bathrooms
E3703.4 Branch Circuit and Feeder Requirements, Bathroom Branch Circuits
A minimum of one 20-ampere branch circuit shall be provided to supply bathroom receptacle outlet(s). Such circuits shall have no other outlets ...
Residential Code 2018 of Kansas > 37 Branch Circuit and Feeder Requirements > E3703 Required Branch Circuits > E3703.4 Bathroom Branch Circuits
E3901.6 Power and Lighting Distribution, Bathroom
At least one receptacle outlet shall be installed in bathrooms and such outlet shall be located within 36 inches (914 mm) of the outside edge of each ...
Residential Code 2018 of Kansas > 39 Power and Lighting Distribution > E3901 Receptacle Outlets > E3901.6 Bathroom
(3) Wiring and Protection, Bathroom Branch Circuits
be provided to supply the bathroom(s) receptacle outlet(s). Such circuits shall have no other outlets. Exception: Where the 20-ampere circuit supplies ...
National Electrical Code 2017 of Kansas > 2 Wiring and Protection > 210 Branch Circuits > 210.11 Branch Circuits Required > (C) Dwelling Units > (3) Bathroom Branch Circuits