• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects General Contractor Building Official & Plans Examiner Inspectors Owner Subcontractors Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Suggested code sections
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

1004.11.3.1.3 Bathing Fixtures

Minnesota Accessibility Code 2015 > 10 Dwelling Units and Sleeping Units > 1004 Type B Units > 1004.11 Toilet and Bathing Facilities > 1004.11.3 Toilet and Bathing Areas > 1004.11.3.1 Option A > 1004.11.3.1.3 Bathing Fixtures
JUMP TO FULL CODE CHAPTER
Where provided, a bathtub shall comply with Section 1004.11.3.1.3.1 or 1004.11.3.1.3.2 and a shower compartment shall comply with Section 1004.11.3.1.3.3.

1004.11.3.1.3.1 Parallel Approach Bathtubs

A clearance 60 inches (1525 mm) minimum in length and 30 inches (760 mm) minimum in width shall be provided in front of bathtubs with a parallel approach. Lavatories complying with Section 606 shall be permitted at the control end of the clearance. A lavatory complying with Section 1004.11.3.1.1 or a water closet shall be permitted at one end of the bathtub if a clearance of 48 inches (1220 mm) minimum in length and 30 inches (760 mm) minimum in width for a parallel approach is provided in front of the bathtub.

FIGURE 1004.11.3.1.3.1
PARALLEL APPROACH BATHTUB IN TYPE B UNITS—OPTION A BATHROOMS

1004.11.3.1.3.2 Forward Approach Bathtubs

A clearance 60 inches (1525 mm) minimum in length and 48 inches (1220 mm) minimum in width shall be provided in front of bathtubs with a forward approach. A water closet and a lavatory shall be permitted in the clearance at one end of the bathtub.

FIGURE 1004.11.3.1.3.2
FORWARD APPROACH BATHTUB IN
TYPE B UNITS—OPTION A BATHROOMS

1004.11.3.1.3.3 Shower Compartment

If a shower compartment is the only bathing facility, the shower compartment shall have dimensions of 36 inches (915 mm) minimum in width and 36 inches (915 mm) minimum in depth. A clearance of 48 inches (1220 mm) minimum in length, measured perpendicular from the shower head wall, and 30 inches (760 mm) minimum in depth, measured from the face of the shower compartment, shall be provided. Reinforcing for a shower seat is not required in shower compartments larger than 36 inches (915 mm) in width and 36 inches (915 mm) in depth.

FIGURE 1004.11.3.1.3.3
TRANSFER-TYPE SHOWER
COMPARTMENT IN TYPE B UNITS

Related Code Sections


1003.11.2.5 Dwelling Units and Sleeping Units, Bathing Fixtures
The accessible bathing fixture shall be a bathtub complying with Section 1003.11.2.5.1 or a shower compartment complying with Section 1003.11.2.5.2 ...
Minnesota Accessibility Code 2015 > 10 Dwelling Units and Sleeping Units > 1003 Type A Units > 1003.11 Toilet and Bathing Facilities > 1003.11.2 General > 1003.11.2.5 Bathing Fixtures
1004.11.3.1.3 Dwelling Units and Sleeping Units, Bathing Fixtures
If a shower compartment is the only bathing facility, the shower compartment shall have dimensions ...
Minnesota Accessibility Code 2015 > 10 Dwelling Units and Sleeping Units > 1004 Type B Units > 1004.11 Toilet and Bathing Facilities > 1004.11.3 Toilet and Bathing Areas > 1004.11.3.1 Option A > 1004.11.3.1.3 Bathing Fixtures
2902.1.2 Plumbing Systems, Family or Assisted-Use Toilet and Bath Fixtures
Fixtures located within family or assisted-use toilet and bathing rooms complying with Minnesota Rules, Chapter 1341, are permitted to be included ...
Minnesota Building Code 2015 > 29 Plumbing Systems > 2902 Minimum Plumbing Facilities > 2902.1 Minimum Number of Fixtures > 2902.1.2 Family or Assisted-Use Toilet and Bath Fixtures
1202.5.2.1 Interior Environment, Bathrooms
Rooms containing bathtubs, showers, spas and similar bathing fixtures shall be mechanically ventilated in accordance with the International ...
2020 Minnesota Building Code > 12 Interior Environment > 1202 Ventilation > 1202.5 Natural Ventilation > 1202.5.2 Contaminants Exhausted > 1202.5.2.1 Bathrooms
1203.4.2.1 Interior Environment, Bathrooms
Rooms containing bathtubs, showers, spas and similar bathing fixtures shall be mechanically ventilated in accordance with the International ...
Minnesota Building Code 2015 > 12 Interior Environment > 1203 Ventilation > 1203.4 Natural Ventilation > 1203.4.2 Contaminants Exhausted > 1203.4.2.1 Bathrooms
Help Contact Us Privacy Terms
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
Code Compare
Code Compare
Highlight differences between any two building codes.
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
TRY FREE FOR TWO WEEKS VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL LEARN MORE