• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects General Contractor Building Official & Plans Examiner Inspectors Owner Subcontractors Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Suggested code sections
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

1926.1101(f)(2)(ii) Basis of Initial Exposure Assessment

OSHA 1926 Construction > Z Toxic and Hazardous Substances > 1926.1101 Asbestos > 1926.1101(f) Exposure Assessments and Monitoring > 1926.1101(f)(2) Initial Exposure Assessment > 1926.1101(f)(2)(ii) Basis of Initial Exposure Assessment
JUMP TO FULL CODE CHAPTER
Unless a negative exposure assessment has been made pursuant to paragraph (f)(2)(iii) of this section, the initial exposure assessment shall, if feasible, be based on monitoring conducted pursuant to paragraph (f)(1)(iii) of this section. The assessment shall take into consideration both the monitoring results and all observations, information or calculations which indicate employee exposure to asbestos, including any previous monitoring conducted in the workplace, or of the operations of the employer which indicate the levels of airborne asbestos likely to be encountered on the job. For Class I asbestos work, until the employer conducts exposure monitoring and documents that employees on that job will not be exposed in excess of the PELs, or otherwise makes a negative exposure assessment pursuant to paragraph (f)(2)(iii) of this section, the employer shall presume that employees are exposed in excess of the TWA and excursion limit.

Related Code Sections


1926.1101(f)(2)(ii) Toxic and Hazardous Substances, Basis of Initial Exposure Assessment
Unless a negative exposure assessment has been made pursuant to paragraph (f)(2)(iii) of this section, the initial exposure assessment shall ...
OSHA 1926 Construction > Z Toxic and Hazardous Substances > 1926.1101 Asbestos > 1926.1101(f) Exposure Assessments and Monitoring > 1926.1101(f)(2) Initial Exposure Assessment > 1926.1101(f)(2)(ii) Basis of Initial Exposure Assessment
1926.62(d)(3)(iv) Occupational Health and Environmental Controls,
(n)(4) of this section, where used in assessing employee exposure in lieu of exposure monitoring ...
OSHA 1926 Construction > D Occupational Health and Environmental Controls > 1926.62 Lead > 1926.62(d) Exposure Assessment > 1926.62(d)(3) Basis of Initial Determination > 1926.62(d)(3)(iv)
1926.62(d)(3)(ii) Occupational Health and Environmental Controls,
Monitoring for the initial determination where performed may be limited to a representative sample of the exposed employees who the employer ...
OSHA 1926 Construction > D Occupational Health and Environmental Controls > 1926.62 Lead > 1926.62(d) Exposure Assessment > 1926.62(d)(3) Basis of Initial Determination > 1926.62(d)(3)(ii)
1926.62(d)(3)(i)(B) Occupational Health and Environmental Controls,
Any previous measurements of airborne lead ...
OSHA 1926 Construction > D Occupational Health and Environmental Controls > 1926.62 Lead > 1926.62(d) Exposure Assessment > 1926.62(d)(3) Basis of Initial Determination > 1926.62(d)(3)(i) > 1926.62(d)(3)(i)(B)
1926.62(d)(3)(iii) Occupational Health and Environmental Controls,
Where the employer has previously monitored for lead exposures, and the data were obtained within the past 12 months during work operations conducted ...
OSHA 1926 Construction > D Occupational Health and Environmental Controls > 1926.62 Lead > 1926.62(d) Exposure Assessment > 1926.62(d)(3) Basis of Initial Determination > 1926.62(d)(3)(iii)
Help Contact Us Privacy Terms
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
Code Compare
Code Compare
Highlight differences between any two building codes.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
TRY FREE FOR TWO WEEKS VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL LEARN MORE