87-322 Base Heights and Transition Heights
JUMP TO FULL CODE CHAPTER
In the Core Subdistrict, the following base heights, required setbacks and maximum transition heights shall apply. Towers are permitted above the maximum heights set forth in this Section only in accordance with Section 87-323 (Tower provisions).
(a) Base heights
(1) Within 50 feet of the shore public walkway For street walls fronting on, or within 50 feet of, the shore public walkway, the maximum base height shall be 85 feet, except that:
(i) on Parcels 1, 2, 3 and 4, as shown on Map 1 in the Appendix to this Chapter, for street walls fronting on a shore public walkway, at least 30 percent of the aggregate width of street walls fronting on the shore public walkway, or a contiguous street wall width of 60 feet, whichever is greater, shall not exceed a maximum height of 45 feet. In addition to being applied along the shore public walkway, such lowered street wall may be applied along intersecting streets within 100 feet of the shore public walkway; and
(ii) on Parcels 5 and 6, as shown on Map 1, such maximum base height shall be 45 feet.
(2) Beyond 50 feet of the shore public walkway and beyond 50 feet of the Major Deegan Expressway street line
Along all other frontages beyond 50 feet of the shore public walkway and beyond 50 feet of the Major Deegan Expressway street line , the street wall shall rise without setback to a minimum base height of 60 feet, or the height of the building, whichever is less, and may rise to a maximum base height of 105 feet.
Along all other frontages beyond 50 feet of the shore public walkway and beyond 50 feet of the Major Deegan Expressway street line , the street wall shall rise without setback to a minimum base height of 60 feet, or the height of the building, whichever is less, and may rise to a maximum base height of 105 feet.
(3) Along, and within 50 feet of, the Major Deegan Expressway street line
Along, and within 50 feet of, the Major Deegan Expressway street line, the street wall shall rise without setback to a minimum base height of 15 feet, or the height of the building, whichever is less, and may rise to a maximum base height of 105 feet.
Along, and within 50 feet of, the Major Deegan Expressway street line, the street wall shall rise without setback to a minimum base height of 15 feet, or the height of the building, whichever is less, and may rise to a maximum base height of 105 feet.
(b) Required setbacks
Above such maximum base height, street walls shall be set back a minimum of 30 feet from the street line along the shore public walkway on Parcel 1, 15 feet from such street line along the shore public walkway on any other parcels, and a minimum of 10 feet from the street line along all other streets. Along all streets, such set back shall have a minimum depth of seven feet from any portion of the street wall below such maximum base height. However, the depth of such setback may include the depth of recesses or outer courts provided that the aggregate width of such portion of a street wall with a reduced setback shall not exceed 30 percent of the street wall.
In addition, on Parcels 1, 2, 3 and 4, in locations where the maximum base height is limited to 45 feet, street walls above such maximum base height shall be set back a minimum of 30 feet from the street line, and a minimum of seven feet from any portion of the street wall below such height.
Dormers provided in accordance with paragraph (c)(1) of Section 23-621 (Permitted obstructions in certain districts) shall be permitted obstructions in all setback areas, except along the shore public walkway. Such dormers shall not exceed the maximum transition height set forth in paragraph (c) of this Section.
Above such maximum base height, street walls shall be set back a minimum of 30 feet from the street line along the shore public walkway on Parcel 1, 15 feet from such street line along the shore public walkway on any other parcels, and a minimum of 10 feet from the street line along all other streets. Along all streets, such set back shall have a minimum depth of seven feet from any portion of the street wall below such maximum base height. However, the depth of such setback may include the depth of recesses or outer courts provided that the aggregate width of such portion of a street wall with a reduced setback shall not exceed 30 percent of the street wall.
In addition, on Parcels 1, 2, 3 and 4, in locations where the maximum base height is limited to 45 feet, street walls above such maximum base height shall be set back a minimum of 30 feet from the street line, and a minimum of seven feet from any portion of the street wall below such height.
Dormers provided in accordance with paragraph (c)(1) of Section 23-621 (Permitted obstructions in certain districts) shall be permitted obstructions in all setback areas, except along the shore public walkway. Such dormers shall not exceed the maximum transition height set forth in paragraph (c) of this Section.
(c) Maximum transition heights
For street walls fronting on, or within 50 feet of, the shore public walkway, street walls above a required setback may rise to a maximum transition height of 125 feet and, along all other frontages, street walls above a required setback may rise to a maximum transition height of 155 feet. Such transition heights may only be exceeded where towers are provided in accordance with the provisions of Section 87-323 (Tower provisions).
For street walls fronting on, or within 50 feet of, the shore public walkway, street walls above a required setback may rise to a maximum transition height of 125 feet and, along all other frontages, street walls above a required setback may rise to a maximum transition height of 155 feet. Such transition heights may only be exceeded where towers are provided in accordance with the provisions of Section 87-323 (Tower provisions).
Related Code Sections
1014.2 Means of Egress, Height
transition between
flights, the fittings or bendings shall be permitted to exceed the maximum height.
In Group R-3 occupancies; within dwelling ...
3314.1.1 Safeguards During Construction or Demolition, Height
For the purposes of this section, the height of a scaffold shall be measured from the base of the scaffold to the top of the uppermost vertical ...
NYC Building Code 2014 > 33 Safeguards During Construction or Demolition > 3314 Scaffolds > 3314.1 Scope > 3314.1.1 Height
3314.1.1 Safeguards During Construction or Demolition, Height
For the purposes of this section, the height of a scaffold shall be measured from the base of the scaffold to the top of the uppermost vertical ...
NYC Building Code 2022 > 33 Safeguards During Construction or Demolition > 3314 Scaffolds > 3314.1 Scope > 3314.1.1 Height
802.9.2.2 Special Rooms and Spaces, Height
Minimum height of the wheelchair space location based ...
Accessible and Usable Buildings and Facilities 2009 of New York City > 8 Special Rooms and Spaces > 802 Assembly Areas > 802.9 Lines of Sight > 802.9.2 Line of Sight Over Standing Spectators > 802.9.2.2 Height
507.8.4 General Building Heights and Areas; Separation of Occupancies, Height Limitations
based on the allowable height and number of stories and feet as set forth in
Section 504 based on the type of construction of the unlimited area ...
NYC Building Code 2022 > 5 General Building Heights and Areas; Separation of Occupancies > 507 Unlimited Area Buildings > 507.8 Group H Occupancies > 507.8.4 Height Limitations