Glass installed in exterior railing in-fill panels or balusters shall be laminated glass complying with Category II of CPSC 16 CFR Part 1201 or Class A of ANSI Z97.1.
Upcodes Diagrams

Related Code Sections

2407.1.4.1 Glass and Glazing, Balusters and In-Fill Panels
Glass installed in exterior railing in-fill panels or balusters shall be laminated glass complying with Category II of CPSC 16 CFR Part 1201 or Class ...
2406.4.4 Glass and Glazing, Glazing in Guards and Railings
Glazing in guards and railings, including structural baluster panels and nonstructural in-fill panels, regardless of area or height above a walking ...
2406.4.4 Glass and Glazing, Glazing in Guards and Railings
Glazing in guards and railings, including structural baluster panels and nonstructural in-fill panels, regardless of area or height above a walking ...
2407.1.2 Glass and Glazing, Guards With Structural Glass Balusters
Guards with structural glass balusters, whether vertical posts, columns or panels, shall be installed with an attached top rail or handrail. The top ...
1607.8.1.2 Structural Design, Intermediate Rails
Intermediate rails (all those except the handrail), balusters and panel fillers shall be designed to resist a concentrated load of 50 pounds (0.22 kN ...