• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects
    Architects
    General Contractors
    General Contractors
    Building Official & Plans Examiners
    Building Official & Plans Examiners
    Inspectors
    Inspectors
    Owners
    Owners
    Subcontractors
    Subcontractors
    Code Consultants
    Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

AS106.13.1 Bale Wall Thickness

California Residential Code 2016 > S Strawbale Construction > AS106 Strawbale Walls—Structural > AS106.13 Braced Panels > AS106.13.1 Bale Wall Thickness
JUMP TO FULL CODE CHAPTER
The thickness of the stacked bale wall without its plaster shall be not less than 15 inches (381 mm).

Related Code Sections


AS106.13.1 Strawbale Construction, Bale Wall Thickness
The thickness of the stacked bale wall without its plaster shall be not less than 15 inches (381 mm) ...
California Residential Code 2016 > S Strawbale Construction > AS106 Strawbale Walls—Structural > AS106.13 Braced Panels > AS106.13.1 Bale Wall Thickness
AS106.13.1 Strawbale Construction, Bale Wall Thickness
The thickness of strawbale braced wall panels without their plaster shall be not less than 15 inches (381 mm) ...
California Residential Code 2019 > S Strawbale Construction > AS106 Strawbale Walls—Structural > AS106.13 Braced Wall Panels > AS106.13.1 Bale Wall Thickness
Section AS108 Strawbale Construction, Thermal Insulation
The unit R -value of a strawbale wall with bales laid flat is R-1.3 per inch of bale thickness. The unit R -value of a strawbale wall with bales ...
California Residential Code 2016 > S Strawbale Construction > AS108 Thermal Insulation
AS108.1 Strawbale Construction, R-Value
The unit R -value of a strawbale wall with bales laid flat is R-1.55 for each inch of bale thickness. The unit R -value of a strawbale wall ...
California Residential Code 2019 > S Strawbale Construction > AS108 Thermal Insulation > AS108.1 R-Value
AS103.2 Strawbale Construction, Size
Bales shall have a height and thickness of not less than 12 inches (305 mm), except as otherwise permitted or required in this appendix. Bales ...
California Residential Code 2019 > S Strawbale Construction > AS103 Bales > AS103.2 Size
Help Contact Us Privacy Terms
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
Code Compare
Code Compare
Highlight differences between any two building codes.
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL PRICING