If balanced doors are used and panic hardware is required, the panic hardware shall be the push-pad type and the pad shall not extend more than one-half the width of the door measured from the latch side.
Upcodes Diagrams

Related Code Sections

1010.1.10.2 Means of Egress, Balanced Doors
If balanced doors are used and panic hardware is required, the panic hardware shall be the push-pad type and the pad shall not extend more than one ...
1010.2.9.4 Means of Egress, Balanced Doors
If balanced doors are used and panic hardware is required, the panic hardware shall be the push-pad type and the pad shall not extend more than one ...
2.11.8 Electric Elevators, Weights for Closing or Balancing Doors
Hoistway door weights, where used for closing or balancing doors, shall be guided or restrained to prevent them from coming out of their runway. The ...