R404.1.7 Backfill Placement
JUMP TO FULL CODE CHAPTER
Backfill shall not be placed against the wall until the wall has sufficient strength and has been anchored to the floor above, or has been sufficiently braced to prevent damage by the backfill.
Exception: Bracing is not required for walls supporting less than 4 feet (1219 mm) of unbalanced backfill.
Related Code Sections
R404.1.7 Foundations, Backfill Placement
Backfill shall not be placed against the wall until the wall has sufficient strength and has been anchored to the floor above, or has been ...
Residential Code 2018 of Kansas > 4 Foundations > R404 Foundation and Retaining Walls > R404.1 Concrete and Masonry Foundation Walls > R404.1.7 Backfill Placement
1804.3 Soils and Foundations, Placement of Backfill
The excavation outside the foundation shall be backfilled with soil that is free of organic material, construction debris, cobbles and boulders ...
Building Code 2018 of Kansas > 18 Soils and Foundations > 1804 Excavation, Grading and Fill > 1804.3 Placement of Backfill
306.2.1 General Regulations, Overexcavation
) in depth and such backfill shall be compacted after each placement ...
Plumbing Code 2018 of Kansas > 3 General Regulations > 306 Trenching, Excavation and Backfill > 306.2 Trenching and Bedding > 306.2.1 Overexcavation
10.9 Underground Requirements, Backfilling
[ 24: 10.9] Backfill material shall be tamped ...
Standard for the Installation of Sprinkler Systems 2016 of Kansas > 10 Underground Requirements > 10.9 Backfilling
1807.3.3 Soils and Foundations, Backfill
The backfill in the annular space around columns not embedded in poured footings shall be by one of the following methods: Backfill shall ...
Building Code 2018 of Kansas > 18 Soils and Foundations > 1807 Foundation Walls, Retaining Walls and Embedded Posts and Poles > 1807.3 Embedded Posts and Poles > 1807.3.3 Backfill