• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects General Contractor Building Official & Plans Examiner Inspectors Owner Subcontractors Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Suggested code sections
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

C405.2.2.1 Automatic Time Switch Control Devices

DC Energy Conservation Code 2013 > 4 [CE] Commercial Energy Efficiency > C405 Electrical Power and Lighting Systems (Mandatory) > C405.2 Lighting Controls (Mandatory) > C405.2.2 Additional Lighting Controls > C405.2.2.1 Automatic Time Switch Control Devices
JUMP TO FULL CODE CHAPTER
Automatic time switch controls shall be installed to control lighting in all areas of the building.
Exception:
  1. Emergency egress lighting does not need to be controlled by an automatic time switch.
  2. Lighting in spaces controlled by occupancy sensors does not need to be controlled by automatic time switch controls.
The automatic time switch control device shall include an override switching device that complies with the following:
  1. The override switch shall be in a readily accessible location;
  2. The override switch shall be located where the lights controlled by the switch are visible; or the switch shall provide a mechanism which announces the area controlled by the switch;
  3. The override switch shall permit manual operation;
  4. The override switch, when initiated, shall permit the controlled lighting to remain on for a maximum of 2 hours; and
  5. Any individual override switch shall control the lighting for a maximum area of 5,000 square feet (465 m2).
Exception: Within malls, arcades, auditoriums, single tenant retail spaces, industrial facilities and arenas:
  1. The time limit shall be permitted to exceed 2 hours provided the override switch is a captive key device; and
  2. The area controlled by the override switch is permitted to exceed 5,000 square feet (465 m2), but shall not exceed 20,000 square feet (1860 m2).

Related Code Sections


C405.2.2.1 [CE] Commercial Energy Efficiency, Automatic Time Switch Control Devices
by automatic time switch controls. The automatic time switch control device shall include an override switching device that complies ...
DC Energy Conservation Code 2013 > 4 [CE] Commercial Energy Efficiency > C405 Electrical Power and Lighting Systems (Mandatory) > C405.2 Lighting Controls (Mandatory) > C405.2.2 Additional Lighting Controls > C405.2.2.1 Automatic Time Switch Control Devices
909.16.3 Fire Protection Systems, Control Action and Priorities
-position firefighter's control panel switch shall allow automatic or manual control action from other control points within the building. The AUTO ...
DC Fire Code 2017 > 9 Fire Protection Systems > 909 Smoke Control Systems > 909.16 Fire Fighter's Smoke Control Panel > 909.16.3 Control Action and Priorities
909.16.3 Fire Protection Systems, Control Action and Priorities
of each three-position firefighter's control panel switch shall allow automatic or manual control action from other control points within the building ...
DC Building Code 2017 > 9 Fire Protection Systems > 909 Smoke Control Systems > 909.16 Fire Fighter's Smoke Control Panel > 909.16.3 Control Action and Priorities
909.16.3 Fire Protection Systems, Control Action and Priorities
-position fire-fighter's control panel switch shall allow automatic or manual control action from other control points within the building. The AUTO ...
DC Building Code 2013 > 9 Fire Protection Systems > 909 Smoke Control Systems > 909.16 Fire-Fighter's Smoke Control Panel > 909.16.3 Control Action and Priorities
909.16.3 Fire Protection Systems, Control Action and Priorities
fire-fighter's control panel switch shall allow automatic or manual control action from other control points within the building. The AUTO position ...
DC Fire Code 2013 > 9 Fire Protection Systems > 909 Smoke Control Systems > 909.16 Fire-Fighter's Smoke Control Panel > 909.16.3 Control Action and Priorities
Help Contact Us Privacy Terms
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
Code Compare
Code Compare
Highlight differences between any two building codes.
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
View thousands of relevant UL Certified products and assemblies that help achieve code compliance
View thousands of relevant UL Certified products and assemblies that help achieve code compliance
Access to UL product and system certification information.
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
TRY FREE FOR TWO WEEKS VISIT PRICING
Join the waitlist
We are looking to gauge the level of interest in linking UL product and system certification information alongside related code sections.

Let us know your email and we’ll ping you once it’s ready! Learn more.

Thank you for your interest!

If you’re open to it, we would love to jump on the phone to make sure we’re building this in the best way possible for your workflow. Any insight or advice would be greatly appreciated. We’ve sent you an email with a calendar link to book at time with us.


Cancel
Get Early Access
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL LEARN MORE