• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects General Contractor Building Official & Plans Examiner Inspectors Owner Subcontractors Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Suggested code sections
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

§4-01 Automatic Door Operators

Title 2 ‒ Board of Standards and Appeals > 4 Doors > §4-01 Automatic Door Operators
JUMP TO FULL CODE CHAPTER
All doors for which approved automatic operators which open by swinging inwardly or by sliding are used shall not constitute more than 50 percent of the required exits for any one particular building, and when such a door operator is used, only half the width of that door can be counted towards the total exit space required for a particular building.  All such door operators shall meet the following requirements:
   (a)   They shall be equipped so that in the event of power failure or fire they may be opened manually in the direction of exit travel by not more than a 30 pound force; and,
   (b)   They may be closed manually when necessary to safeguard a means of egress; and,
   (c)   Swinging panels shall provide a clear opening width in the 90° open position of not less than 32 inches, with no single leaf less than 24 inches in width; and,
   (d)   When swinging panels are contained in sliding door units, they shall be operable when the sliding leaf or leaves retract to any point in the opening cycle; and,
   (e)   They shall meet the requirements of the American National Standard for Power Operated Doors, ANSI A156.10-1979; and
   (f)   They shall meet the requirements of ANSI/UL 325 (or ANSI/UL 1578 when it is adopted), shall be listed or labeled by a nationally recognized independent testing laboratory, and shall be under an inplant follow-up inspection service.  These requirements shall be applicable to all such door operators approved in the past and those which shall be approved in the future, but shall not be applicable to particular installations of approved door operators which were installed before April 15, 1980.

Related Code Sections


Article 14 Elevators [PDF] (page 23)
be unnecessary to reach back of any panel, jamb or sash to operate such doors. c. Horizontally swinging type hoistway doors of automatic operation elevators ...
NYC 1938 Code [PDF] > 14 Elevators
3102.10.2 Special Construction, Exit Openings From Air-Supported Structures and Air-Inflated Structures
Exit doors in air-supported structures and air-inflated structures shall close automatically against normal operational pressures. Opening force ...
NYC Building Code 2008 > 31 Special Construction > 3102 Membrane Structures > 3102.10 Exits > 3102.10.2 Exit Openings From Air-Supported Structures and Air-Inflated Structures
3102.10.2 Special Construction, Exit Openings From Air-Supported Structures and Air-Inflated Structures
Exit doors in air-supported structures and air-inflated structures shall close automatically against normal operational pressures. Opening force ...
NYC Building Code 2014 > 31 Special Construction > 3102 Membrane Structures > 3102.10 Exits > 3102.10.2 Exit Openings From Air-Supported Structures and Air-Inflated Structures
§27-513 Special Uses and Occupancies, Exits
-supported structure shall not exceed seventy-five feet. Exit doors in air-supported structures shall close automatically against normal operational ...
NYC 1968 Code (Vol I) > 7 Special Uses and Occupancies > 19 Tents and Air-Supported Structures > §27-513 Exits
Article 14 Elevators [PDF] (page 3)
term “door closer” shall mean a device, operated by gravity or other means, which will automatically close a door when such device is released ...
NYC 1938 Code [PDF] > 14 Elevators
Help Contact Us Privacy Terms
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Code Compare
Code Compare
Highlight differences between any two building codes.
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
TRY FREE FOR TWO WEEKS VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL LEARN MORE