• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects General Contractor Building Official & Plans Examiner Inspectors Owner Subcontractors Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Suggested code sections
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

3108F.4 Automated Fire Detection System

Los Angeles Building Code > 31F [SLC] Marine Oil Terminals > 3108F Fire Prevention, Detection and Suppression > 3108F.4 Automated Fire Detection System
JUMP TO FULL CODE CHAPTER

An MOT shall have a permanently installed automated fire detection or sensing system (N).

Fire detection systems shall be tested and maintained per the manufacturer or the local enforcing agency requirements.

Specifications shall be retained. The latest testing and maintenance records shall be readily accessible to the Division (N/E).

Related Code Sections


3108F.4 [SLC] Marine Oil Terminals, Automated Fire Detection System
An MOT shall have a permanently installed automated fire detection or sensing system (N). Fire detection systems shall be tested and maintained per ...
Los Angeles Building Code > 31F [SLC] Marine Oil Terminals > 3108F Fire Prevention, Detection and Suppression > 3108F.4 Automated Fire Detection System
Section 3209 High-Piled Combustible Storage, Automated Storage
of the following: An automatic smoke detection system installed in accordance with Section 907, with coverage extending 15 feet (4575 mm) in all ...
2017 LA City Fire Code > 32 High-Piled Combustible Storage > 3209 Automated Storage
2406.4 Flammable Finishes, Fire Protection
Areas used for powder coating shall be protected by an approved automatic fire-extinguishing system complying with Chapter 9 ...
2017 LA City Fire Code > 24 Flammable Finishes > 2406 Powder Coating > 2406.4 Fire Protection
2407.4 Flammable Finishes, Fire Protection
Areas used for electrostatic spray finishing with fixed equipment shall be protected with an approved automatic fire-extinguishing system complying ...
2017 LA City Fire Code > 24 Flammable Finishes > 2407 Electrostatic Apparatus > 2407.4 Fire Protection
2404.8.1 Flammable Finishes, Automated Spray Application Operations
Where protecting automated spray application operations, automatic fire-extinguishing systems shall be equipped with an approved interlock feature ...
2017 LA City Fire Code > 24 Flammable Finishes > 2404 Spray Finishing > 2404.8 Interlocks > 2404.8.1 Automated Spray Application Operations
Help Contact Us Privacy Terms
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
View thousands of relevant UL Certified products and assemblies that help achieve code compliance
View thousands of relevant UL Certified products and assemblies that help achieve code compliance
Access to UL product and system certification information.
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Code Compare
Code Compare
Highlight differences between any two building codes.
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
TRY FREE FOR TWO WEEKS VISIT PRICING
Join the waitlist
We are looking to gauge the level of interest in linking UL product and system certification information alongside related code sections.

Let us know your email and we’ll ping you once it’s ready! Learn more.

Thank you for your interest!

If you’re open to it, we would love to jump on the phone to make sure we’re building this in the best way possible for your workflow. Any insight or advice would be greatly appreciated. We’ve sent you an email with a calendar link to book at time with us.


Cancel
Get Early Access
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL LEARN MORE