• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects General Contractor Building Official & Plans Examiner Inspectors Owner Subcontractors Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Suggested code sections
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

Appendix C Audiometric Measuring Instruments

OSHA 1910 General Industry > G Occupational Health and Environmental Control > 1910.95 Occupational Noise Exposure > C Audiometric Measuring Instruments
JUMP TO FULL CODE CHAPTER
This Appendix is Mandatory

  1. In the event that pulsed-tone audiometers are used, they shall have a tone on-time of at least 200 milliseconds.
  2. Self-recording audiometers shall comply with the following requirements:
    1. The chart upon which the audiogram is traced shall have lines at positions corresponding to all multiples of 10 dB hearing level within the intensity range spanned by the audiometer. The lines shall be equally spaced and shall be separated by at least 1/4 inch. Additional increments are optional. The audiogram pen tracings shall not exceed 2 dB in width.
    2. It shall be possible to set the stylus manually at the 10-dB increment lines for calibration purposes.
    3. The slewing rate for the audiometer attenuator shall not be more than 6 dB/sec except that an initial slewing rate greater than 6 dB/sec is permitted at the beginning of each new test frequency, but only until the second subject response.
    4. The audiometer shall remain at each required test frequency for 30 seconds (+ or - 3 seconds). The audiogram shall be clearly marked at each change of frequency and the actual frequency change of the audiometer shall not deviate from the frequency boundaries marked on the audiogram by more than + or - 3 seconds.
    5. It must be possible at each test frequency to place a horizontal line segment parallel to the time axis on the audiogram, such that the audiometric tracing crosses the line segment at least six times at that test frequency. At each test frequency the threshold shall be the average of the midpoints of the tracing excursions.

Related Code Sections


Appendix C Occupational Health and Environmental Control, Audiometric Measuring Instruments
axis on the audiogram, such that the audiometric tracing crosses the line segment at least six times at that test frequency. At each test frequency ...
OSHA 1910 General Industry > G Occupational Health and Environmental Control > 1910.95 Occupational Noise Exposure > C Audiometric Measuring Instruments
1910.95 Occupational Health and Environmental Control, Occupational Noise Exposure
All audiograms obtained pursuant to this section shall meet the requirements of Appendix C: "Audiometric Measuring Instruments ...
OSHA 1910 General Industry > G Occupational Health and Environmental Control > 1910.95 Occupational Noise Exposure
Appendix D Occupational Health and Environmental Control, Audiometric Test Rooms
This Appendix is Mandatory Rooms used for audiometric testing shall not have background sound pressure levels exceeding those in Table D-1 when ...
OSHA 1910 General Industry > G Occupational Health and Environmental Control > 1910.95 Occupational Noise Exposure > D Audiometric Test Rooms
1910.95(g)(7)(iii)(C) Occupational Health and Environmental Control,
Measurements of background sound pressure levels in the audiometric test room as required in Appendix D: Audiometric Test Rooms ...
OSHA 1910 General Industry > G Occupational Health and Environmental Control > 1910.95 Occupational Noise Exposure > 1910.95(g) Audiometric Testing Program > 1910.95(g)(7) Evaluation of Audiogram > 1910.95(g)(7)(iii) > 1910.95(g)(7)(iii)(C)
1910.95(m)(2)(ii)(F) Occupational Health and Environmental Control,
The employer shall maintain accurate records of the measurements of the background sound pressure levels in audiometric test rooms ...
OSHA 1910 General Industry > G Occupational Health and Environmental Control > 1910.95 Occupational Noise Exposure > 1910.95(m) Recordkeeping > 1910.95(m)(2) Audiometric Tests > 1910.95(m)(2)(ii) > 1910.95(m)(2)(ii)(F)
Help Contact Us Privacy Terms
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Code Compare
Code Compare
Highlight differences between any two building codes.
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
TRY FREE FOR TWO WEEKS VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL LEARN MORE