407.2.2.3 Audible Signals
JUMP TO FULL CODE CHAPTER
Audible signals shall sound once for the up direction and twice for the down direction, or shall have verbal annunciators that indicate the direction of elevator car travel. Audible signals shall have a frequency of 1500 Hz maximum. Verbal annunciators shall have a frequency of 300 Hz minimum and 3000 Hz maximum. The audible signal and verbal annunciator shall be 10 dB minimum above ambient, but shall not exceed 80 dB, measured at the hall call button.
EXCEPTIONS:
- Destination-oriented elevators shall not be required to comply with 407.2.2.3 provided that the audible tone and verbal announcement is the same as those given at the call button or call button keypad.
- Existing elevators shall not be required to comply with the requirements for frequency and dB range of audible signals.
Related Code Sections
407.2.2.3 Accessible Routes, Audible Signals
Audible signals shall sound once for the up direction and twice for the down direction, or shall have verbal annunciators that indicate the direction ...
Texas Accessibility Standards 2012 > 4 Accessible Routes > 407 Elevators > 407.2 Elevator Landing Requirements > 407.2.2 Hall Signals > 407.2.2.3 Audible Signals
904.4.2.1 Fire Protection Systems, Audible and Visible Signals
The audibility and visibility of notification appliances signaling agent discharge or system operation, where required, shall be verified ...
Building Code of the Texas Industrialized Housing and Buildings Program > 9 Fire Protection Systems > 904 Alternative Automatic Fire-Extinguishing Systems > 904.4 Inspection and Testing > 904.4.2 Alarm Testing > 904.4.2.1 Audible and Visible Signals
606.4.1 Duct Systems, Supervision
Code . The actuation of a duct smoke detector shall activate a visible and audible supervisory signal at a constantly attended location. In facilities ...
Mechanical Code of the Texas Industrialized Housing and Buildings Program > 6 Duct Systems > 606 Smoke Detection Systems Control > 606.4 Controls Operation > 606.4.1 Supervision
907.3.1 Fire Protection Systems, Duct Smoke Detectors
initiate a visible and audible supervisory signal at a constantly attended location and shall perform the intended fire safety function ...
Building Code of the Texas Industrialized Housing and Buildings Program > 9 Fire Protection Systems > 907 Fire Alarm and Detection Systems > 907.3 Fire Safety Functions > 907.3.1 Duct Smoke Detectors
407.4.8.2.1 Accessible Routes, Signal Type
other than destination-oriented elevators that have a rated speed of 200 feet per minute (1 m/s) or less, a non-verbal audible signal with a frequency ...
Texas Accessibility Standards 2012 > 4 Accessible Routes > 407 Elevators > 407.4 Elevator Car Requirements > 407.4.8 Car Position Indicators > 407.4.8.2 Audible Indicators > 407.4.8.2.1 Signal Type