11B-411.2.1.7.3 Assignment by Security Credential
JUMP TO FULL CODE CHAPTER
If a security system or other form of access control system is provided, the audio output shall provide a verbal announcement and direction to the location of the access control activation sensor, such as "present security credential at the sensor immediately to the left". Upon presentation of security credential, the destination floor shall be confirmed by verbal announcement and on the display screen. The display screen shall indicate the elevator assignment characters and a verbal announcement shall be made of the assigned elevator responding to the call. Visual and verbal direction to the assigned elevator shall be provided.
Related Code Sections
11B-411.2.1.7.3 Accessibility to Public Buildings, Public Accommodations, Commercial Buildings and Public Housing, Assignment by Security Credential
to the location of the access control activation sensor, such as "present security credential at the sensor immediately to the left". Upon presentation ...
Los Angeles Building Code > 11B Accessibility to Public Buildings, Public Accommodations, Commercial Buildings and Public Housing > 11B-411 Destination-Oriented Elevators > 11B-411.2 Elevator Landing Requirements > 11B-411.2.1 Hall Call Consoles > 11B-411.2.1.7 Elevator Car Assignment > 11B-411.2.1.7.3 Assignment by Security Credential