• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects General Contractor Building Official & Plans Examiner Inspectors Owner Subcontractors Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Suggested code sections
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

C304.3.2 Assembly U -Factor, C -Factor and F -Factor Calculation

2017 FBC - Energy Conservation, 6th edition > 3 [CE] General Requirements > C304 Materials Testing and Thermal Properties > C304.3 Calculation Procedures and Assumptions > C304.3.2 Assembly U -Factor, C -Factor and F -Factor Calculation
JUMP TO FULL CODE CHAPTER

C304.3.2.1 Pre-Calculated Assembly U-Factors, C -Factors, F -Factors or Heat Capacities

The U-factors, C-factors, F-factors, and heat capacities for typical construction assemblies from ASHRAE 90.1 Normative Appendix A shall be used for all calculations unless otherwise allowed by applicant-determined assembly U-factors, C-factors, F-factors or heat capacities. Interpolation between values for rated R-values of insulation, including insulated, sheathing is allowed; extrapolation beyond values in the ASHRAE 90.1 Normative Appendix A tables is not.

C304.3.2.2 Applicant-Determined Assembly U-Factors, C -Factors, F -Factors or Heat Capacities

If the building official determines that the proposed construction assembly is not adequately represented in the appropriate table of ASHRAE 90.1 Normative Appendix A, the applicant shall determine appropriate values for the assembly using the assumptions in ASHRAE 90.1 Normative Appendix A. An assembly is deemed to be adequately represented if:

  1. the interior structure, hereafter referred to as the base assembly, for the class of construction is the same as described in Normative Appendix A and
  2. changes in exterior or interior surface building materials added to the base assembly do not increase or decrease the R-value by more than 2 from that indicated in the descriptions in ASHRAE 90.1 Normative Appendix A.

Insulation, including insulated sheathing, is not considered a building material.

Related Code Sections


C304.3.2 [CE] General Requirements, Assembly U -Factor, C -Factor and F -Factor Calculation
be used for all calculations unless otherwise allowed by applicant-determined assembly U -factors, C -factors, F -factors or heat capacities ...
2017 FBC - Energy Conservation, 6th edition > 3 [CE] General Requirements > C304 Materials Testing and Thermal Properties > C304.3 Calculation Procedures and Assumptions > C304.3.2 Assembly U -Factor, C -Factor and F -Factor Calculation
C304.3.2 [CE] General Requirements, Assembly U -Factor, C -Factor and F -Factor Calculation
be used for all calculations unless otherwise allowed by applicant-determined assembly U -factors, C -factors, F -factors or heat capacities ...
2020 FBC - Energy Conservation, 7th edition > 3 [CE] General Requirements > C304 Materials Testing and Thermal Properties > C304.3 Calculation Procedures and Assumptions > C304.3.2 Assembly U -Factor, C -Factor and F -Factor Calculation
C304.3.2 [CE] General Requirements, Assembly U-factor, C-Factor and F-Factor Calculation
for all calculations unless otherwise allowed by applicant-determined assembly U -factors, C -factors, F -factors, or heat capacities ...
2014 FBC - Energy Conservation, 5th edition > 3 [CE] General Requirements > C304 Materials Testing and Thermal Properties > C304.3 Calculation Procedures and Assumptions > C304.3.2 Assembly U-factor, C-Factor and F-Factor Calculation
C304.3.2.2 [CE] General Requirements, Applicant-Determined Assembly U-Factors, C-Factors, F-Factors, or Heat Capacities
If the building official determines that the proposed construction assembly is not adequately represented in the appropriate table of ASHRAE 90.1 ...
2014 FBC - Energy Conservation, 5th edition > 3 [CE] General Requirements > C304 Materials Testing and Thermal Properties > C304.3 Calculation Procedures and Assumptions > C304.3.2 Assembly U-factor, C-Factor and F-Factor Calculation > C304.3.2.2 Applicant-Determined Assembly U-Factors, C-Factors, F-Factors, or Heat Capacities
C304.3 [CE] General Requirements, Calculation Procedures and Assumptions
be used for all calculations unless otherwise allowed by applicant-determined assembly U -factors, C -factors, F -factors or heat capacities ...
2020 FBC - Energy Conservation, 7th edition > 3 [CE] General Requirements > C304 Materials Testing and Thermal Properties > C304.3 Calculation Procedures and Assumptions
Help Contact Us Privacy Terms
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
View thousands of relevant UL Certified products and assemblies that help achieve code compliance
View thousands of relevant UL Certified products and assemblies that help achieve code compliance
Access to UL product and system certification information.
Code Compare
Code Compare
Highlight differences between any two building codes.
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
TRY FREE FOR TWO WEEKS VISIT PRICING
Join the waitlist
We are looking to gauge the level of interest in linking UL product and system certification information alongside related code sections.

Let us know your email and we’ll ping you once it’s ready! Learn more.

Thank you for your interest!

If you’re open to it, we would love to jump on the phone to make sure we’re building this in the best way possible for your workflow. Any insight or advice would be greatly appreciated. We’ve sent you an email with a calendar link to book at time with us.


Cancel
Get Early Access
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL LEARN MORE