• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects General Contractor Building Official & Plans Examiner Inspectors Owner Subcontractors Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Suggested code sections
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

§27-292.11 Assembly Spaces

NYC 1968 Code (Vol I) > 4 Building Limitations > 2 Building Access > §27-292 Building Access > §27-292.11 Assembly Spaces
JUMP TO FULL CODE CHAPTER
(a) Assembly spaces other than places of assembly shall be provided with a minimum of accessible wheelchair viewing positions as follows:
Capacity of Assembly
Space
Number of Viewing
Positions
1 to 25 Minimum 1
26 to 50 Minimum 2
51 to 74 Minimum 3
(b) Places of assembly shall be provided with accessible wheelchair viewing positions in accordance with subparagraph h of paragraph (1) of subdivision (a) of section 27-531. (c) Size and placement of wheelchair location, surfaces, access to performing area and listening systems, where required, shall comply with the provisions of reference standard RS 4-6. These positions may be utilized by persons who do not use wheelchairs provided that the positions are delineated on the approved seating plans, the seating is readily removable and the positions are unsold one full working day before the performance.

Related Code Sections


§27-292.11 Building Limitations, Assembly Spaces
(a) Assembly spaces other than places of assembly shall be provided with a minimum of accessible wheelchair viewing positions as follows ...
NYC 1968 Code (Vol I) > 4 Building Limitations > 2 Building Access > §27-292 Building Access > §27-292.11 Assembly Spaces
§27-531 Places of Assembly, Seating in Assembly Spaces
All seating in assembly spaces shall conform to the following: (a) Seating arrangements.- Except as otherwise provided in this subchapter, all ...
NYC 1968 Code (Vol I) > 8 Places of Assembly > 2 Basic Requirements > §27-531 Seating in Assembly Spaces
1028.17.1 Means of Egress, Classification of Exit Openings
to the assembly space, and that open directly to a safe area or to an open exterior space. Class 2—Exit openings that are not used for normal entry ...
NYC Building Code 2014 > 10 Means of Egress > 1028 Assembly > 1028.17 Places of Assembly With an Occupant Load of Less Than 12 Square Feet Per Person > 1028.17.1 Classification of Exit Openings
1024.17.1 Means of Egress, Classification of Exit Openings
for normal entry to the assembly space, and that open directly to a safe area or to an open exterior space.   2. Class 2—Exit openings ...
NYC Building Code 2008 > 10 Means of Egress > 1024 Assembly > 1024.17 Places of Assembly With an Occupant Load of Less Than 12 Square Feet Per Person > 1024.17.1 Classification of Exit Openings
§28-117.2 Administration, Temporary Place of Assembly Certificate of Operation
At the commissioner's discretion, a temporary certificate of operation may be issued for a place of assembly space upon request by the applicant ...
NYC General Admin. Provisions 2014 > 1 Administration > 117 Places of Assembly > §28-117.2 Temporary Place of Assembly Certificate of Operation
Help Contact Us Privacy Terms
Code Compare
Code Compare
Highlight differences between any two building codes.
View thousands of relevant UL Certified products and assemblies that help achieve code compliance
View thousands of relevant UL Certified products and assemblies that help achieve code compliance
Access to UL product and system certification information.
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
TRY FREE FOR TWO WEEKS VISIT PRICING
Join the waitlist
We are looking to gauge the level of interest in linking UL product and system certification information alongside related code sections.

Let us know your email and we’ll ping you once it’s ready! Learn more.

Thank you for your interest!

If you’re open to it, we would love to jump on the phone to make sure we’re building this in the best way possible for your workflow. Any insight or advice would be greatly appreciated. We’ve sent you an email with a calendar link to book at time with us.


Cancel
Get Early Access
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL LEARN MORE