CODE SNIPPET

1029.13 Assembly Aisle Walking Surfaces

Building Code 2015 of Utah > 10 Means of Egress > 1029 Assembly > 1029.13 Assembly Aisle Walking Surfaces
JUMP TO FULL CODE CHAPTER
Share URL

Copy and paste the link below into emails, chats or browsers.


You can also copy or bookmark the link from your browser's address bar.
Ramped aisles shall comply with Sections 1029.13.1 through 1029.13.1.3. Stepped aisles shall comply with Sections 1029.13.2 through 1029.13.2.4.

1029.13.1 Ramped Aisles

Share URL

Copy and paste the link below into emails, chats or browsers.


You can also copy or bookmark the link from your browser's address bar.
Aisles that are sloped more than one unit vertical in 20 units horizontal (5-percent slope) shall be considered a ramped aisle. Ramped aisles that serve as part of an accessible route in accordance with Sections 1009 and 1108.2 shall have a maximum slope of one unit vertical in 12 units horizontal (8-percent slope). The slope of other ramped aisles shall not exceed one unit vertical in 8 units horizontal (12.5-percent slope).

1029.13.1.1 Cross Slope

Share URL

Copy and paste the link below into emails, chats or browsers.


You can also copy or bookmark the link from your browser's address bar.
The slope measured perpendicular to the direction of travel of a ramped aisle shall not be steeper than one unit vertical in 48 units horizontal (2-percent slope).

1029.13.1.2 Landings

Share URL

Copy and paste the link below into emails, chats or browsers.


You can also copy or bookmark the link from your browser's address bar.
Ramped aisles shall have landings in accordance with Sections 1012.6 through 1012.6.5. Landings for ramped aisles shall be permitted to overlap required aisles or cross aisles.

1029.13.1.3 Edge Protection

Share URL

Copy and paste the link below into emails, chats or browsers.


You can also copy or bookmark the link from your browser's address bar.
Ramped aisles shall have edge protection in accordance with Sections 1012.10 and 1012.10.1.

Exception: In assembly spaces with fixed seating, edge protection is not required on the sides of ramped aisles where the ramped aisles provide access to the adjacent seating and aisle accessways.

1029.13.2 Stepped Aisles

Share URL

Copy and paste the link below into emails, chats or browsers.


You can also copy or bookmark the link from your browser's address bar.
Aisles with a slope exceeding one unit vertical in eight units horizontal (12.5-percent slope) shall consist of a series of risers and treads that extends across the full width of aisles and complies with Sections 1029.13.2.1 through 1029.13.2.4.

1029.13.2.1 Treads

Share URL

Copy and paste the link below into emails, chats or browsers.


You can also copy or bookmark the link from your browser's address bar.
Tread depths shall be not less than 11 inches (279 mm) and shall have dimensional uniformity.

Exception: The tolerance between adjacent treads shall not exceed 3/16 inch (4.8 mm).

1029.13.2.2 Risers

Share URL

Copy and paste the link below into emails, chats or browsers.


You can also copy or bookmark the link from your browser's address bar.
Where the gradient of stepped aisles is to be the same as the gradient of adjoining seating areas, the riser height shall be not less than 4 inches (102 mm) nor more than 8 inches (203 mm) and shall be uniform within each flight.

Exceptions:

1. Riser height nonuniformity shall be limited to the extent necessitated by changes in the gradient of the adjoining seating area to maintain adequate sightlines. Where nonuniformities exceed 3/16 inch (4.8 mm) between adjacent risers, the exact location of such nonuniformities shall be indicated with a distinctive marking stripe on each tread at the nosing or leading edge adjacent to the nonuniform risers. Such stripe shall be not less than 1 inch (25 mm), and not more than 2 inches (51 mm), wide. The edge marking stripe shall be distinctively different from the contrasting marking stripe.

2. Riser heights not exceeding 9 inches (229 mm) shall be permitted where they are necessitated by the slope of the adjacent seating areas to maintain sightlines.

1029.13.2.2.1 Construction Tolerances

Share URL

Copy and paste the link below into emails, chats or browsers.


You can also copy or bookmark the link from your browser's address bar.
The tolerance between adjacent risers on a stepped aisle that were designed to be equal height shall not exceed 3/16 inch (4.8 mm). Where the stepped aisle is designed in accordance with Exception 1 of Section 1029.13.2.2, the stepped aisle shall be constructed so that each riser of unequal height, determined in the direction of descent, is not more than 3/8 inch (9.5 mm) in height different from adjacent risers where stepped aisle treads are less than 22 inches (560 mm) in depth and 3/4 inch (19.1 mm) in height different from adjacent risers where stepped aisle treads are 22 inches (560 mm) or greater in depth.

1029.13.2.3 Tread Contrasting Marking Stripe

Share URL

Copy and paste the link below into emails, chats or browsers.


You can also copy or bookmark the link from your browser's address bar.
A contrasting marking stripe shall be provided on each tread at the nosing or leading edge such that the location of each tread is readily apparent when viewed in descent. Such stripe shall be not less than 1 inch (25 mm), and not more than 2 inches (51 mm), wide.

Exception: The contrasting marking stripe is permitted to be omitted where tread surfaces are such that the location of each tread is readily apparent when viewed in descent.

1029.13.2.4 Nosing and Profile

Share URL

Copy and paste the link below into emails, chats or browsers.


You can also copy or bookmark the link from your browser's address bar.
Nosing and riser profile shall comply with Sections 1011.5.5 through 1011.5.5.3.

Related Code Sections


1029.13 Means of Egress, Assembly Aisle Walking Surfaces
Ramped aisles shall comply with Sections 1029.13.1 through 1029.13.1.3. Stepped aisles shall comply with Sections 1029.13.2 through 1029.13.2.4 ...
Building Code 2015 of Utah > 10 Means of Egress > 1029 Assembly > 1029.13 Assembly Aisle Walking Surfaces
1029.13.2.1 Means of Egress, Treads
Tread depths shall be not less than 11 inches (279 mm) and shall have dimensional uniformity. Exception: The tolerance between adjacent treads ...
Building Code 2015 of Utah > 10 Means of Egress > 1029 Assembly > 1029.13 Assembly Aisle Walking Surfaces > 1029.13.2 Stepped Aisles > 1029.13.2.1 Treads
1029.13.2.2 Means of Egress, Risers
Where the gradient of stepped aisles is to be the same as the gradient of adjoining seating areas, the riser height shall be not less than 4 inches ...
Building Code 2015 of Utah > 10 Means of Egress > 1029 Assembly > 1029.13 Assembly Aisle Walking Surfaces > 1029.13.2 Stepped Aisles > 1029.13.2.2 Risers
1029.13.2.2.1 Means of Egress, Construction Tolerances
The tolerance between adjacent risers on a stepped aisle that were designed to be equal height shall not exceed 3 / 16 inch (4.8 mm). Where ...
Building Code 2015 of Utah > 10 Means of Egress > 1029 Assembly > 1029.13 Assembly Aisle Walking Surfaces > 1029.13.2 Stepped Aisles > 1029.13.2.2 Risers > 1029.13.2.2.1 Construction Tolerances
1029.13.2.3 Means of Egress, Tread Contrasting Marking Stripe
marking stripe is permitted to be omitted where tread surfaces are such that the location of each tread is readily apparent when viewed in descent ...
Building Code 2015 of Utah > 10 Means of Egress > 1029 Assembly > 1029.13 Assembly Aisle Walking Surfaces > 1029.13.2 Stepped Aisles > 1029.13.2.3 Tread Contrasting Marking Stripe
   About UpCodes

UpCodes provides an intuitive resource to navigate building regulations.

Codes are organized by jurisdiction to help you understand which regulations apply to your project.


Find Your Codes
COMPANY INFO About Resources Contact Careers Terms Privacy
CATEGORY General New York City New York State California Codes Building Codes Online
PREMIUM Features Pricing Sign Up Log In
CODES IBC 2015 IRC 2015 IPC 2015 California Building Code 2016 Popular Sections

FOLLOW US