• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects General Contractor Building Official & Plans Examiner Inspectors Owner Subcontractors Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Suggested code sections
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

R609.6 Assemblies and Beams Spanning Openings

2014 FBC - Residential, 5th edition > 6 Wall Construction > R609 Grouted Masonry > R609.6 Assemblies and Beams Spanning Openings
JUMP TO FULL CODE CHAPTER

R609.6.1 Preengineered Assemblies for Masonry Walls

R609.6.1.1

Unreinforced masonry units above an opening and 8-inch (203 mm) high bond beams above an opening shall be supported by an assembly.

R609.6.1.2

Preengineered assemblies shall be selected from a manufacturer's approved schedule or other approved tables for the load capacities based on the appropriate minimum gravity load carrying capacities established in Tables R609.6.1.2(1), R609.6.1.2(2), and R609.6.1.2(3).

TABLE R609.6.1.2(1)
SUPERIMPOSED LOADS MINIMUM RATED LOAD CAPACITY OF 6-INCHOR 8-INCH-THICK PREENGINEERED ASSEMBLIES SPANNING OPENINGS OF ONE STORY AND TOP STORY OF MULTISTORY BUILDINGS1,3,4
ROOF SPAN (FT)UPLIFT (plf)
GRAVITY (plf)Vasd as determined in accordance with Section R301.2.1.3
100 mph120 mph140 mph
4215085112165
12330152204305
24600262351525
36870374502745
441,050451605900
521,2305307101,055
601,4106098161,215
Notes:
  1. All loads are superimposed at the top of the wall and do not include dead loads of the bond beam or masonry above the assembly. Add 100 percent of additional dead loads to the gravity loads and subtract 85 percent of these loads from the uplift loads.
  2. Use 4-foot (1220 mm) roof span for assemblies in endwalls.
  3. For total roof dead loads over 10 psf, increase gravity loads by the following amount: (Roof Dead Load - 10 psf) × (Roof Span + 2 ft)/2.
  4. Uplift rating is required only if a pre-engineered assembly is used to directly support a roof. See Section R609.6.1.3 for cases where uplift need not be considered.
TABLE R609.6.1.2(2)
SUPERIMPOSED LOADS MINIMUM RATED LOAD CAPACITY 8-INCH-THICK PREENGINEERED ASSEMBLIES SPANNING OPENINGS OF BOTTOM STORY OF TWO-STORY BUILDINGS, SECOND AND BOTTOM STORIES OF THREE-STORY BUILDINGS— WOOD FLOOR SYSTEM3,4,5
FLOOR SPAN1 (FT)MINIMUM RATED GRAVITY LOAD ASSEMBLY (plf)
ASSEMBLY CLEAR SPAN (FT)
468121620
42210260310410510610
12430480530630730830
247608108609601,0601,160
361,0901,1401,1901,2901,3901,490
441,3101,3601,4101,5101,6101,710
521,5301,5801,6301,7301,8301,930
601,7501,8001,8501,9502,0502,150
Notes:
  1. For a wall supporting floors on both sides, enter table with the sum of the 2 full spans.

    NOTE: Tabular values are for half the load of the full span shown.
  2. Use 4-foot (1220 mm) building width for assemblies in walls not supporting floors (normally endwalls and interior masonry walls and shearwalls).
  3. The values in this table may be interpolated.
  4. These loads take into account the dead load of any masonry in the wall above the assembly and live and dead loads of the roof and floor supported. Dead load of the assembly is not included in the table and if not included in the preengineered concrete design must be added to the loads in the table.
  5. This table is applicable for all roof dead loads.
TABLE R609.6.1.2(3)
SUPERIMPOSED LOADS MINIMUM RATED LOAD CAPACITY 8-INCH-THICK PREENGINEERED ASSEMBLIES SPANNING OPENINGS OF BOTTOM STORY OF TWO-STORY BUILDINGS, SECOND AND BOTTOM STORIES OF THREE-STORY BUILDINGS—HOLLOWCORE FLOOR SYSTEM3,4,5
FLOOR SPAN1 (FT)MINIMUM RATED GRAVITY LOAD ASSEMBLY (plf)
ASSEMBLY CLEAR SPAN (FT)
468121620
42290340390490590690
126707207708709701,070
241,2401,2901,3401,4401,5401,640
361,8101,8601,9102,0102,1102,210
442,1902,2402,2902,3902,4902,590
522,5702,6202,6702,7702,8702,970
602,9503,0003,0503,1503,2503,350
Notes:
  1. For a wall supporting floors on both sides, enter table with the sum of the 2 full spans.

    NOTE: Tabular values are for half the load of the full span shown.
  2. Use 4-foot (1220 mm) building width for assemblies in nonfloor bearing walls (normally endwalls and interior masonry walls and shearwalls).
  3. The values in this table may be interpolated.
  4. These loads take into account the dead load of any masonry in the wall above the assembly and live and dead loads of the roof and floor supported. Dead load of the assembly is not included in the table and if not included in the preengineered concrete assembly design must be added to the loads in the table.
  5. This table is applicable for all roof dead loads.

R609.6.1.3

Preengineered assemblies may function as a bond beam over an opening provided that:
  1. The bond beam reinforcement is continuous through the assembly.
  2. The assembly has an uplift rating that equals or exceeds the appropriate value stipulated in Table R609.6.1.2(1) if the lintel directly supports a roof.
Exception: If the reinforcement in the top of the assembly is equal to or greater than the reinforcement required in the bottom of the assembly by the manufacturer, uplift need not be considered.

R609.6.1.4

Preengineered assemblies spanning openings shall extend a minimum of 4 inches (102 mm) nominal past each side of the opening.

R609.6.2 Continuous Bond Beams Spanning Openings

R609.6.2.1

Under the provisions of this section, bond beams shall:
  1. Be 16 inches (406 mm) high nominal over openings, except cast-in-place concrete bond beams, which may be 12 inches (305 mm) high nominal.
  2. Have top reinforcement continuous over the wall and opening.
  3. Have bottom reinforcement extending past each side of the opening a minimum of 24 inches (610 mm) for concrete walls and 4 inches (102 mm) for masonry walls.
  4. Meet the provisions of Tables R609.6.2.1(1), R609.6.2.1(2) and R609.6.2.1(3) as appropriate.
TABLE R609.6.2.1(1)
MAXIMUM CLEAR SPAN CAPACITY OF CONTINUOUS BOND BEAMS ACTING AS LINTELS
ONE STORY AND TOP STORY OF MULTISTORY BUILDINGS
ROOF SPAN (FT) MAXIMUM ALLOWABLE CLEAR SPAN (FT-IN)5
BOND BEAM 6" THICK WALL1, 2, 4 BOND BEAM 8" THICK WALL1, 2, 4
16-1 16-2 C12-1 C12-2 C16-1 C16-2 16-1 16-2 C12-1 C12-2 C16-1 C16-2
43 16-0 17-4 16-0 20-8 18-0 24-8 16-0 18-8 15-4 20-8 17-4 23-4
12 12-0 13-4 12-0 15-4 14-0 18-8 12-8 14-0 11-4 16-0 13-4 18-0
24 8-8 8-8 9-4 10-8 10-8 14-8 10-0 11-4 8-8 12-8 10-8 14-8
36 6-8 6-8 8-0 8-0 9-4 11-4 8-8 8-8 7-4 10-0 8-8 12-0
44 6-0 6-0 7-4 7-4 8-0 10-0 7-4 7-4 6-8 8-8 8-0 11-4
52 5-4 5-4 6-0 6-0 8-0 8-8 6-8 6-8 6-8 8-0 7-4 10-8
60 4-8 4-8 6-0 6-0 7-4 8-0 6-0 6-0 6-0 7-4 7-4 10-0

Notes:

  1. Designation of bond beam types over openings:
    1. Letter C designates a concrete bond beam. All other bond beams are masonry.
    2. The first number denotes the nominal height of the bond beam in inches.
    3. The second number denotes the number of No. 5 reinforcing bars in the top and the bottom of the beam. A single (1) No. 7 bar may be used in lieu of two No. 5 bars. The bottom reinforcing steel shall be located no more than 23/4-inches (70 mm) clear distance from the bottom of masonry bond beams and 11/2 inches (38 mm) for concrete bond beams.
  2. All bond beams have reinforcement in the top as required by Tables R609.2.2A-1 through 609.2.2A-4 and Tables R609.2.2B-1 through R609.2.2B-8 as appropriate. If two No.5 are required in this table and only one No.5 is required by Tables R609.2.2A-1 through R609.2.2A-4 and Tables R609.2.2B-1 through R609.2.2B-8 as appropriate, the additional bar shall be placed in the top of the bond beam over the opening and shall extend past the opening a minimum of 24 inches (610 mm).
  3. Use 4-foot (1219 mm) roof span for lintels in endwalls.
  4. The bottom reinforcement in precast lintels may be used to satisfy the continuous bond beam bottom reinforcement requirement.
  5. For roof dead loads more than 10 psf:
    1. For 20 psf roof dead load, multiply allowable clear spans by 0.85.
    2. For 30 psf roof dead load, multiply allowable clear spans by 0.75.
    3. Values for other roof dead loads may be interpolated.


TABLE R609.6.2.1(2)
MAXIMUM CLEAR SPAN OF CONTINUOUS BOND BEAMS ACTING AS LINTELS BOTTOM STORY OF TWO-STORY BUILDINGS, SECOND AND BOTTOM STORIES OF THREE-STORY BUILDINGS—WOOD FLOOR SYSTEM
BUILDING WIDTH (FT) BOND BEAM 8" THICK WALL1, 2, 4
16-1 16-2 C12-1 C12-2 C16-1 C16-2 C16-3
MAXIMUM ALLOWABLE CLEAR SPAN (FT-IN)5
43 11-4 13-4 10-8 14-0 12-0 15-4 18-0
12 10-0 11-4 9-4 12-0 10-8 14-0 16-0
24 8-8 8-8 8-0 10-0 8-8 12-0 12-8
36 6-8 6-8 6-8 8-0 8-0 10-8 10-8
44 6-0 6-0 6-0 7-4 7-4 9-4 9-4
52 5-4 5-4 6-0 6-8 6-8 8-8 8-8
60 4-8 4-8 5-4 6-0 6-8 8-0 8-0

Notes:

  1. Designation of bond beam over openings:
    1. Letter C designates a concrete bond beam. All other bond beams are masonry.
    2. The first number denotes the nominal height of the bond beam in inches.
    3. The second number denotes the number of No. 5 reinforcing bars in the top and the bottom of the beam. One No. 7 may be used in lieu of two No. 5. The bottom reinforcing steel shall be located no more than 23/4-inches (70 mm) clear distance from the bottom of masonry bond beams and 11/2 inches (38 mm) for concrete bond beams.
  2. All bond beams shall have reinforcement in the top in accordance with Section R609.6.2.
  3. Use 4-foot (1219 mm) floor span for lintels in walls parallel to hollowcore.
  4. The bottom reinforcement in precast lintels may be used to satisfy the continuous bond beam bottom reinforcement requirement.
  5. This table is applicable for all roof dead loads.


TABLE R609.6.2.1(3)
MAXIMUM CLEAR SPAN OF CONTINUOUS BOND BEAMS ACTING LINTELS BOTTOM STORY OF TWO-STORY BUILDINGS,
SECOND AND BOTTOM STORIES OF THREE-STORY BUILDINGS—HOLLOWCORE SECOND FLOOR
BUILDING WIDTH (FT) BOND BEAM 8" THICK WALL1, 2, 4
16-1 16-2 C12-1 C12-2 C16-1 C16-2 C16-3
MAXIMUM ALLOWABLE CLEAR SPAN (FT-IN)5
43 10-8 12-0 10-0 13-4 11-4 14-8 17-4
12 8-8 9-4 8-0 10-8 9-4 12-0 13-4
24 6-0 6-0 6-0 7-4 7-4 10-0 10-0
36 4-8 4-8 5-4 6-0 6-0 8-0 8-0
44 4-0 4-0 4-8 5-4 6-0 7-4 7-4
52 4-0 4-0 4-8 4-8 5-4 6-8 6-8
60 3-4 3-4 4-0 4-0 5-4 6-0 6-0

Notes:

  1. Designation of bond beam over openings:
    1. Letter C designates a concrete bond beam. All other bond beams are masonry.
    2. The first number denotes the nominal height of the bond beam in inches.
    3. The second number denotes the number of No. 5 reinforcing bars in the top and the bottom of the beam. One No. 7 may be used in lieu of two No. 5. The bottom reinforcing steel shall be located no more than 23/4-inches (70 mm) clear distance from the bottom of masonry bond beams and 11/2 inches (38 mm) for concrete bond beams.
  2. All bond beams shall have reinforcement in the top in accordance with Section R609.6.2.
  3. Use 4-foot (1219 mm) floor span for lintels in walls parallel to hollowcore.
  4. The bottom reinforcement in precast lintels may be used to satisfy the continuous bond beam bottom reinforcement requirement.
  5. This table is applicable for all roof dead loads.

R609.6.2.2

Top reinforcement required over the opening which is in addition to that required over the wall shall extend past the opening a minimum of 24 inches (610 mm).

R609.6.2.3

When preengineered assemblies are utilized to form the bottom portion of the bond beam over the opening in masonry walls, the bottom reinforcement of the preengineered assemblies shall be counted toward the additional bottom reinforcement required over the opening.

R609.6.3 Bond Beams Combined With Lintels

R609.6.3.1

The provisions of this section shall apply when the lintel, the wall area between the lintel and the bond beam, and the bond beam itself are solid grouted masonry units or cast together as one unit.
SEE MORE

Related Code Sections


R609.6 Wall Construction, Assemblies and Beams Spanning Openings
Unreinforced masonry units above an opening and 8-inch (203 mm) high bond beams above an opening shall be supported by an assembly ...
2014 FBC - Residential, 5th edition > 6 Wall Construction > R609 Grouted Masonry > R609.6 Assemblies and Beams Spanning Openings
R609.6.1.3 Wall Construction,
Preengineered assemblies may function as a bond beam over an opening provided that: The bond beam reinforcement is continuous through ...
2014 FBC - Residential, 5th edition > 6 Wall Construction > R609 Grouted Masonry > R609.6 Assemblies and Beams Spanning Openings > R609.6.1 Preengineered Assemblies for Masonry Walls > R609.6.1.3
R609.6.1.2 Wall Construction,
R609.6.1.2(1) SUPERIMPOSED LOADS MINIMUM RATED LOAD CAPACITY OF 6-INCHOR 8-INCH-THICK PREENGINEERED ASSEMBLIES SPANNING OPENINGS OF ONE STORY AND TOP ...
2014 FBC - Residential, 5th edition > 6 Wall Construction > R609 Grouted Masonry > R609.6 Assemblies and Beams Spanning Openings > R609.6.1 Preengineered Assemblies for Masonry Walls > R609.6.1.2
R609.6.2.3 Wall Construction,
When preengineered assemblies are utilized to form the bottom portion of the bond beam over the opening in masonry walls, the bottom reinforcement ...
2014 FBC - Residential, 5th edition > 6 Wall Construction > R609 Grouted Masonry > R609.6 Assemblies and Beams Spanning Openings > R609.6.2 Continuous Bond Beams Spanning Openings > R609.6.2.3
R609.6.2.1 Wall Construction,
Under the provisions of this section, bond beams shall: Be 16 inches (406 mm) high nominal over openings, except cast-in-place concrete bond beams ...
2014 FBC - Residential, 5th edition > 6 Wall Construction > R609 Grouted Masonry > R609.6 Assemblies and Beams Spanning Openings > R609.6.2 Continuous Bond Beams Spanning Openings > R609.6.2.1
Help Contact Us Privacy Terms
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
View thousands of relevant UL Certified products and assemblies that help achieve code compliance
View thousands of relevant UL Certified products and assemblies that help achieve code compliance
Access to UL product and system certification information.
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
Code Compare
Code Compare
Highlight differences between any two building codes.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
TRY FREE FOR TWO WEEKS VISIT PRICING
Join the waitlist
We are looking to gauge the level of interest in linking UL product and system certification information alongside related code sections.

Let us know your email and we’ll ping you once it’s ready! Learn more.

Thank you for your interest!

If you’re open to it, we would love to jump on the phone to make sure we’re building this in the best way possible for your workflow. Any insight or advice would be greatly appreciated. We’ve sent you an email with a calendar link to book at time with us.


Cancel
Get Early Access
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL LEARN MORE