• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects
    Architects
    General Contractors
    General Contractors
    Building Official & Plans Examiners
    Building Official & Plans Examiners
    Inspectors
    Inspectors
    Owners
    Owners
    Subcontractors
    Subcontractors
    Code Consultants
    Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

1615.2.11 ASCE 7 Table 6.7-2

2018 Washington State Building Code > 16 Structural Design > 1615 Tsunami Loads > 1615.2 Modifications to ASCE 7 > 1615.2.11 ASCE 7 Table 6.7-2
JUMP TO FULL CODE CHAPTER
Modify ASCE 7 Table 6.7-2 to read as follows:

Table 6.7-2
Maximum Moment Magnitude
Subduction Zone
Moment Magnitude
MWmax
Alaskan-Aleutian
9.2
Cascadia
9.0 
Chile-Peru
9.5
Izu-Bonin-Mariana
9.0
Kamchatka-Kurile and
Japan Trench
9.4

Related Code Sections


1615.2.11 Structural Design, ASCE 7 Table 6.7-2
Modify ASCE 7 Table 6.7-2 to read as follows: Table 6.7-2 Maximum Moment Magnitude Subduction Zone Moment Magnitude MWmax ...
2018 Washington State Building Code > 16 Structural Design > 1615 Tsunami Loads > 1615.2 Modifications to ASCE 7 > 1615.2.11 ASCE 7 Table 6.7-2
6.7 System Components and Hardware, Fire Department Connections
Unless the requirements of 6.7.1.1, 6.7.1.2, or 6.7.1.3 are met, the fire department connection (s) shall consist of two 21/2 in. (65 mm) connections ...
Standard for the Installation of Sprinkler Systems 2016 of Washington > 6 System Components and Hardware > 6.7 Fire Department Connections
6.7 Structural Analysis, Elastic Second-Order Analysis
An elastic second-order analysis shall consider the influence of axial loads, presence of cracked regions along the length of the member, and effects ...
Building Code Requirements for Structural Concrete of Washington > 6 Structural Analysis > 6.7 Elastic Second-Order Analysis
6.7 Fire Walls, Fire Walls With Elevation Differences
Where a fire wall separates parts of a building having different heights, the fire wall shall be permitted to terminate in accordance with one ...
Standard for Challenge Fire Walls, Fire Walls, and Fire Barrier Walls 2015 of Washington > 6 Fire Walls > 6.7 Fire Walls With Elevation Differences
6.7 System Components and Hardware, Valves
When water pressures exceed 175 psi (12.1 bar), valves shall be used in accordance with their pressure ratings ...
Standard for the Installation of Sprinkler Systems 2013 of Washington > 6 System Components and Hardware > 6.7 Valves
Help Contact Us Privacy Terms
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
Code Compare
Code Compare
Highlight differences between any two building codes.
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
TRY FREE FOR TWO WEEKS VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL PRICING