105.3.6 Asbestos Removal
JUMP TO FULL CODE CHAPTER
Moving, removal or disposal of asbestos-containing materials on a residential building where the owner occupies the building, the building is not for sale or lease, and the work is performed according to the owner-builder limitations provided in this paragraph. To qualify for exemption under this paragraph, an owner must personally appear and sign the building permit application. The permitting agency shall provide the person with a disclosure statement in substantially the following form:
- Disclosure Statement: State law requires asbestos abatement to be done by licensed contractors. You have applied for a permit under an exemption to that law. The exemption allows you, as the owner of your property, to act as your own asbestos abatement contractor even though you do not have a license. You must supervise the construction yourself. You may move, remove or dispose of asbestos-containing materials on a residential building where you occupy the building and the building is not for sale or lease, or the building is a farm outbuilding on your property. If you sell or lease such building within 1 year after the asbestos abatement is complete, the law will presume that you intended to sell or lease the property at the time the work was done, which is a violation of this exemption. You may not hire an unlicensed person as your contractor. Your work must be done according to all local, state and federal laws and regulations which apply to asbestos abatement projects. It is your responsibility to make sure that people employed by you have licenses required by state law and by county or municipal licensing ordinances.
Related Code Sections
105.3.6 Scope and Administration, Asbestos Removal
Moving, removal or disposal of asbestos-containing materials on a residential building where the owner occupies the building, the building ...
2017 FBC - Building, 6th edition > 1 Scope and Administration > 105 Permits > 105.3 Application for Permit > 105.3.6 Asbestos Removal
105.3.6 Scope and Administration, Asbestos Removal
Moving, removal or disposal of asbestos-containing materials on a residential building where the owner occupies the building, the building ...
2014 FBC - Building, 5th edition > 1 Scope and Administration > 105 Permits > 105.3 Application for Permit > 105.3.6 Asbestos Removal
105.3.6 Scope and Administration, Asbestos Removal
Moving, removal or disposal of asbestos-containing materials on a residential building where the owner occupies the building, the building ...
2020 FBC - Building, 7th edition > 1 Scope and Administration > 105 Permits > 105.3 Application for Permit > 105.3.6 Asbestos Removal
105.3.6 Scope and Administration, Asbestos Removal
Moving, removal or disposal of asbestos-containing materials on a residential building where the owner occupies the building, the building ...
2020 FBC - Residential, 7th edition > 1 Scope and Administration > 105 Permits > 105.3 Application for Permit > 105.3.6 Asbestos Removal
105.3.6 Scope and Administration, Asbestos Removal
Moving, removal or disposal of asbestos-containing materials on a residential building where the owner occupies the building, the building ...
2020 FBC - Fuel Gas, 7th edition > 1 Scope and Administration > 105 Permits > 105.3 Application for Permit > 105.3.6 Asbestos Removal