3307.6.2 Areas to Be Protected
JUMP TO FULL CODE CHAPTER
Protection shall be provided for those sidewalks or walkways that are in front of the building to be constructed, altered, or demolished. Sidewalks or walkways in a plaza or other similar space that lead from the street to an entrance or exit into or out of the building that cannot be officially closed shall be similarly protected.
Where deemed necessary by the commissioner, the deck shall cover the entire width of the sidewalk or walkway in front of the building, except for reasonably small clearances at the building line and the curb. In all other instances, the sidewalk shed shall protect the sidewalk or walkway to a minimum 5 foot (1524 mm) width. Sidewalk sheds may extend beyond the curb to such extent as may be approved by the Department of Transportation pursuant to a permit from such department.
Unless constructed solely to comply with Section 3307.3.1, item 3, sidewalk sheds shall extend 5 feet (1524 mm) past the building when the building is less than 100 feet (30 480 mm) in height, and 20 feet (6096 mm) past the building when the building is over 100 feet (30 480 mm) in height, regardless of whether such extensions are in front of the property being developed or in front of adjacent property. Extensions of sidewalk sheds complying with the foregoing shall be constructed so as not to unreasonably obstruct, either visually or physically, entrances, egress, driveways, and show windows of adjacent properties.
Related Code Sections
3307.6.2 Safeguards During Construction or Demolition, Areas to Be Protected
Protection shall be provided for those sidewalks or walkways that are in front of the building to be constructed, altered, or demolished. Sidewalks ...
NYC Building Code 2008 > 33 Safeguards During Construction or Demolition > 3307 Protection of Pedestrians > 3307.6 Sidewalk Sheds > 3307.6.2 Areas to Be Protected
3307.6.3 Safeguards During Construction or Demolition, Area to Be Protected
, the shed shall protect the full length of the area specified in Section 3307.6.2 plus an additional 20 feet (6096 mm) on both sides beyond such length ...
NYC Building Code 2014 > 33 Safeguards During Construction or Demolition > 3307 Protection of Pedestrians > 3307.6 Sidewalk Sheds > 3307.6.3 Area to Be Protected
3306.9.8 Safeguards During Construction or Demolition, Hazards to Be Removed
Prior to the commencement of demolition operations, the area ...
NYC Building Code 2014 > 33 Safeguards During Construction or Demolition > 3306 Demolition > 3306.9 Safeguards > 3306.9.8 Hazards to Be Removed
507.10 General Building Heights and Areas; Separation of Occupancies, Group E Buildings
The area of a Group E building of Type IIA, IIIA or IV construction shall not be limited where the building is protected throughout with an approved ...
NYC Building Code 2014 > 5 General Building Heights and Areas; Separation of Occupancies > 507 Unlimited Area Buildings > 507.10 Group E Buildings
507.8 General Building Heights and Areas; Separation of Occupancies, Group E Buildings
The area of a Group E building of Type IIA, IIIA or IV construction shall not be limited where the building is protected throughout with an approved ...
NYC Building Code 2008 > 5 General Building Heights and Areas; Separation of Occupancies > 507 Unlimited Area Buildings > 507.8 Group E Buildings