2607.4 Area Limitation and Separation
JUMP TO FULL CODE CHAPTER
The maximum area of a single wall panel and minimum vertical and horizontal separation requirements for exterior light-transmitting plastic wall panels shall be as provided for in Table 2607.4. The maximum percentage of wall area of any story in light-transmitting plastic wall panels shall not exceed that indicated in Table 2607.4 or the percentage of unprotected openings permitted by Section 705.8, whichever is smaller.
For SI: 1 foot = 304.8 mm, 1 square foot = 0.0929 m2.
Exceptions:
TABLE 2607.4 AREA LIMITATION AND SEPARATION REQUIREMENTS FOR LIGHT-TRANSMITTING PLASTIC WALL PANELSa - In structures provided with approved flame barriers extending 30 inches (760 mm) beyond the exterior wall in the plane of the floor, a vertical separation is not required at the floor except that provided by the vertical thickness of the flame barrier projection.
- Veneers of approved weather-resistant light-transmitting plastics used as exterior siding in buildings of Type V construction in compliance with Section 1406.
- The area of light-transmitting plastic wall panels in exterior walls of greenhouses shall be exempt from the area limitations of Table 2607.4 but shall be limited as required for unprotected openings in accordance with Section 704.8.
FIRE SEPARATION DISTANCE (feet) | CLASS OF PLASTIC | MAXIMUM PERCENTAGE AREA OF EXTERIOR WALL IN PLASTIC WALL PANELS | MAXIMUM SINGLE AREA OF PLASTIC WALL PANELS (square feet) | MINIMUM SEPARATION OF PLASTIC WALL PANELS (feet) | |
Vertical | Horizontal | ||||
Less than 6 | — | Not Permitted | Not Permitted | — | — |
6 or more but less than 11 | CC1 | 10 | 50 | 8 | 4 |
CC2 | Not Permitted | Not Permitted | — | — | |
11 or more but less than or equal to 30 | CC1 | 25 | 90 | 6 | 4 |
CC2 | 15 | 70 | 8 | 4 | |
Over 30 | CC1 | 50 | Not Limited | 3b | 0 |
CC2 | 50 | 100 | 6b | 3 |
- For combinations of plastic glazing and plastic wall panel areas permitted, see Section 2607.6.
- For reductions in vertical separation allowed, see Section 2607.4.
Related Code Sections
1406.11.3.4 Exterior Walls, Area Limitation and Separation
The maximum area of a single MCM panel and the minimum vertical and horizontal separation requirements for MCM panels shall be as provided ...
Building Code 2018 of Utah > 14 Exterior Walls > 1406 Metal Composite Materials (MCM) > 1406.11 Alternate Conditions > 1406.11.3 Installations Up to 75 Feet in Height (Option 1) > 1406.11.3.4 Area Limitation and Separation
1407.11.3.4 Exterior Walls, Area Limitation and Separation
The maximum area of a single MCM panel and the minimum vertical and horizontal separation requirements for MCM panels shall be as provided ...
Building Code 2015 of Utah > 14 Exterior Walls > 1407 Metal Composite Materials (MCM) > 1407.11 Alternate Conditions > 1407.11.3 Installations Up to 75 Feet in Height (Option 1) > 1407.11.3.4 Area Limitation and Separation
2607.4 Plastic, Area Limitation and Separation
for unprotected openings in accordance with Section 705.8. TABLE 2607.4 AREA LIMITATION AND SEPARATION REQUIREMENTS FOR LIGHT-TRANSMITTING ...
Building Code 2018 of Utah > 26 Plastic > 2607 Light-Transmitting Plastic Wall Panels > 2607.4 Area Limitation and Separation
2607.4 Plastic, Area Limitation and Separation
as required for unprotected openings in accordance with Section 704.8.
TABLE 2607.4 AREA LIMITATION AND SEPARATION REQUIREMENTS FOR ...
Building Code 2015 of Utah > 26 Plastic > 2607 Light-Transmitting Plastic Wall Panels > 2607.4 Area Limitation and Separation
2610.8 Plastic, Combinations of Roof Panels and Skylights
Combinations of light-transmitting plastic roof panels and skylights shall be subject to the area and percentage limitations and separation ...
Building Code 2018 of Utah > 26 Plastic > 2610 Light-Transmitting Plastic Skylight Glazing > 2610.8 Combinations of Roof Panels and Skylights