• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects
    Architects
    General Contractors
    General Contractors
    Building Official & Plans Examiners
    Building Official & Plans Examiners
    Inspectors
    Inspectors
    Owners
    Owners
    Subcontractors
    Subcontractors
    Code Consultants
    Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

505.2.1 Area Limitation

Building Code 2018 of Illinois > 5 General Building Heights and Areas > 505 Mezzanines and Equipment Platforms > 505.2 Mezzanines > 505.2.1 Area Limitation
JUMP TO FULL CODE CHAPTER
The aggregate area of a mezzanine or mezzanines within a room shall be not greater than one-third of the floor area of that room or space in which they are located. The enclosed portion of a room shall not be included in a determination of the floor area of the room in which the mezzanine is located. In determining the allowable mezzanine area, the area of the mezzanine shall not be included in the floor area of the room.
Exceptions:
  1. The aggregate area of mezzanines in buildings and structures of Type I or II construction for special industrial occupancies in accordance with Section 503.1.1 shall be not greater than two-thirds of the floor area of the room.
  2. The aggregate area of mezzanines in buildings and structures of Type I or II construction shall be not greater than one-half of the floor area of the room in buildings and structures equipped throughout with an approved automatic sprinkler system in accordance with Section 903.3.1.1 and an approved emergency voice/alarm communication system in accordance with Section 907.5.2.2.
  3. The aggregate area of a mezzanine within a dwelling unit that is located in a building equipped throughout with an approved automatic sprinkler system in accordance with Section 903.3.1.1 or 903.3.1.2 shall not be greater than one-half of the floor area of the room, provided that:
    1. 3.1. Except for enclosed closets and bathrooms, the mezzanine shall be open to the room in which such mezzanine is located;
    2. 3.2. The opening to the room shall be unobstructed except for walls not more than 42 inches (1067 mm) in height, columns and posts; and
    3. 3.3. Exceptions to Section 505.2.3 shall not be permitted.

505.2.1.1 Aggregate Area of Mezzanines and Equipment Platforms

Where a room contains both a mezzanine and an equipment platform, the aggregate area of the two raised floor levels shall be not greater than two-thirds of the floor area of that room or space in which they are located. The area of the mezzanine shall not exceed the area determined in accordance with Section 505.2.1.

Related Code Sections


1102.2 Additions, Area Limitations
An addition shall not increase the area of an existing building beyond that permitted under the applicable provisions of Chapter 5 ...
Existing Building Code 2018 of Illinois > 11 Additions > 1102 Heights and Areas > 1102.2 Area Limitations
1102.2 Additions, Area Limitations
An addition shall not increase the area of an existing building beyond that permitted under the applicable provisions of Chapter 5 ...
Existing Building Code 2021 of Illinois > 11 Additions > 1102 Heights and Areas > 1102.2 Area Limitations
1510.1.1 Roof Assemblies and Rooftop Structures, Area Limitation
The aggregate area of penthouses and other enclosed rooftop structures shall not exceed one-third the area of the supporting roof deck. Such ...
Building Code 2018 of Illinois > 15 Roof Assemblies and Rooftop Structures > 1510 Rooftop Structures > 1510.1 General > 1510.1.1 Area Limitation
1511.1.1 Roof Assemblies and Rooftop Structures, Area Limitation
The aggregate area of penthouses and other enclosed rooftop structures shall not exceed one-third the area of the supporting roof deck. Such ...
Building Code 2021 of Illinois > 15 Roof Assemblies and Rooftop Structures > 1511 Rooftop Structures > 1511.1 General > 1511.1.1 Area Limitation
2604.2.3 Plastic, Area Limitation
The interior trim shall not constitute more than 10 percent of the specific wall or ceiling areas to which it is attached ...
Building Code 2021 of Illinois > 26 Plastic > 2604 Interior Finish and Trim > 2604.2 Interior Trim > 2604.2.3 Area Limitation
Help Contact Us Privacy Terms
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
Code Compare
Code Compare
Highlight differences between any two building codes.
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL PRICING