406.3.2 Area Increase
Go To Full Code Chapter
Group U occupancies used for the storage of private or pleasure-type motor vehicles where no repair work is completed or fuel is dispensed are permitted to be 3,000 square feet (279 m2) where the following provisions are met:
- For a mixed occupancy building, the exterior wall and opening protection for the Group U portion of the building shall be as required for the major occupancy of the building. For such a mixed occupancy building, the allowable floor area of the building shall be as permitted for the major occupancy contained therein.
- For a building containing only a Group U occupancy, the exterior wall shall not be required to have a fire-resistance rating and the area of openings shall not be limited where the fire separation distance is 5 feet (1524 mm) or more.
Related Code Sections
406.3.2 Special Detailed Requirements Based on Use and Occupancy, Area Increase
, the allowable floor area of the building shall be as permitted for the major occupancy contained therein.
For a building containing only a Group U ...
506.3.3 General Building Heights and Areas, Amount of Increase
The area factor increase based on frontage shall be determined in accordance with Equation 5-5: (Equation 5-5) where: If = Area factor increase ...
406.5.5 Special Detailed Requirements Based on Occupancy and Use, Area and Height Increases
The allowable area and height of open parking garages shall be increased in accordance with the provisions of this section. Garages with sides open ...
3412.6.2.1 Existing Buildings and Structures, Allowable Area Formula
(square feet).
At
=
Tabular building area per story in accordance with Table 503 (square feet).
Is
=
Area increase factor due ...
506.1 General Building Heights and Areas, General
The building areas limited by Table 503 shall be permitted to be increased due to frontage (If) and automatic sprinkler system protection (Is ...