3314.11.5 Arcing Prevention
JUMP TO FULL CODE CHAPTER
Precautions shall be taken to prevent the possibility of arcing through the suspension wire rope.
The suspension wire rope shall be covered with insulating material extending at least 4 feet (1219 mm) above the hoist. If there is a tail line below the hoist, it shall be insulated to prevent contact with the platform. The portion of the tail line that hangs free below the scaffold shall be guided or retained or both so that it does not become grounded.
Each hoist shall be covered with insulated protective covers.
In addition to a work lead attachment required by the welding process, a grounding conductor shall be connected from the scaffold to the structure. The size of the connector shall be at least the size of the welding process work lead, and this conductor shall not be in series with the welding process or the work piece.
If the scaffold grounding lead is disconnected at any time, the welding machine shall be shut off.
An active welding rod or uninsulated welding lead shall not be allowed to make contact with the scaffold or its suspension system.
Related Code Sections
3314.11.5 Safeguards During Construction or Demolition, Arcing Prevention
Precautions shall be taken to prevent the possibility of arcing through the suspension wire rope ...
NYC Building Code 2008 > 33 Safeguards During Construction or Demolition > 3314 Scaffolds > 3314.11 Suspension Rope > 3314.11.5 Arcing Prevention
3314.11.5 Safeguards During Construction or Demolition, Suspended Scaffold Welding Precautions for Arcing Prevention
Precautions shall be taken to prevent the possibility of arcing through the suspension wire rope during welding operations ...
NYC Building Code 2014 > 33 Safeguards During Construction or Demolition > 3314 Scaffolds > 3314.11 Suspension Rope > 3314.11.5 Suspended Scaffold Welding Precautions for Arcing Prevention
3314.11.5.6 Safeguards During Construction or Demolition, Welding Rod or Lead
An active welding rod or uninsulated welding lead shall not be allowed to make contact with the scaffold or its suspension system ...
NYC Building Code 2008 > 33 Safeguards During Construction or Demolition > 3314 Scaffolds > 3314.11 Suspension Rope > 3314.11.5 Arcing Prevention > 3314.11.5.6 Welding Rod or Lead
3314.11.5.2 Safeguards During Construction or Demolition, Insulating Material
the hoist, it shall be insulated to prevent contact with the platform. The portion of the tail line that hangs free below the scaffold shall ...
NYC Building Code 2014 > 33 Safeguards During Construction or Demolition > 3314 Scaffolds > 3314.11 Suspension Rope > 3314.11.5 Suspended Scaffold Welding Precautions for Arcing Prevention > 3314.11.5.2 Insulating Material
3314.11.5.1 Safeguards During Construction or Demolition, Insulated Thimble
An insulated thimble shall be used to attach each suspension wire rope to its hanging support. Excessive suspension wire rope and any additional ...
NYC Building Code 2014 > 33 Safeguards During Construction or Demolition > 3314 Scaffolds > 3314.11 Suspension Rope > 3314.11.5 Suspended Scaffold Welding Precautions for Arcing Prevention > 3314.11.5.1 Insulated Thimble