• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects
    Architects
    General Contractors
    General Contractors
    Building Official & Plans Examiners
    Building Official & Plans Examiners
    Inspectors
    Inspectors
    Owners
    Owners
    Subcontractors
    Subcontractors
    Code Consultants
    Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

1926.752(a) Approval to Begin Steel Erection

OSHA 1926 Construction > R Steel Erection > 1926.752 Site Layout, Site-Specific Erection Plan and Construction Sequence > 1926.752(a) Approval to Begin Steel Erection
JUMP TO FULL CODE CHAPTER
Before authorizing the commencement of steel erection, the controlling contractor shall ensure that the steel erector is provided with the following written notifications:

1926.752(a)(1)

The concrete in the footings, piers and walls and the mortar in the masonry piers and walls has attained, on the basis of an appropriate ASTM standard test method of field-cured samples, either 75 percent of the intended minimum compressive design strength or sufficient strength to support the loads imposed during steel erection.

1926.752(a)(2)

Any repairs, replacements and modifications to the anchor bolts were conducted in accordance with § 1926.755(b).

Related Code Sections


1926.752(a) Steel Erection, Approval to Begin Steel Erection
Before authorizing the commencement of steel erection, the controlling contractor shall ensure that the steel erector is provided with the following ...
OSHA 1926 Construction > R Steel Erection > 1926.752 Site Layout, Site-Specific Erection Plan and Construction Sequence > 1926.752(a) Approval to Begin Steel Erection
Subpart R Steel Erection
Authority : Section 3704 of the Contract Work Hours and Safety Standards Act (40 U.S.C. 3701); Sections 4, 6, and 8 of the Occupational Safety ...
OSHA 1926 Construction > R Steel Erection
1926.757(d) Steel Erection, Erection Bridging
of bolted diagonal erection bridging shall be installed near the third points of the steel joist ...
OSHA 1926 Construction > R Steel Erection > 1926.757 Open Web Steel Joists > 1926.757(d) Erection Bridging
Subpart R Steel Erection, App E - Training: Non-Mandatory Guidelines for Complying With 1926.761
The training requirements of § 1926.761 will be deemed to have been met if employees have completed a training course on steel erection, including ...
OSHA 1926 Construction > R Steel Erection > R App E - Training: Non-Mandatory Guidelines for Complying With 1926.761
1926.754(d) Steel Erection, Plumbing-Up
When deemed necessary by a competent person, plumbing-up equipment shall be installed in conjunction with the steel erection process to ensure ...
OSHA 1926 Construction > R Steel Erection > 1926.754 Structural Steel Assembly > 1926.754(d) Plumbing-Up
Help Contact Us Privacy Terms
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
Code Compare
Code Compare
Highlight differences between any two building codes.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL PRICING