• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects
    Architects
    General Contractors
    General Contractors
    Building Official & Plans Examiners
    Building Official & Plans Examiners
    Inspectors
    Inspectors
    Owners
    Owners
    Subcontractors
    Subcontractors
    Code Consultants
    Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

201 Application

2010 ADA Standards > 2 Scoping Requirements > 201 Application
JUMP TO FULL CODE CHAPTER

201.1 Scope

ILLUSTRATION
All areas of newly designed and newly constructed buildings and facilities and altered portions of existing buildings and facilities shall comply with these requirements.
Advisory 201.1 Scope.  These requirements are to be applied to all areas of a facility unless exempted, or where scoping limits the number of multiple elements required to be accessible.  For example, not all medical care patient rooms are required to be accessible; those that are not required to be accessible are not required to comply with these requirements.  However, common use and public use spaces such as recovery rooms, examination rooms, and cafeterias are not exempt from these requirements and must be accessible.

201.2 Application Based on Building or Facility Use

Where a site, building, facility, room, or space contains more than one use, each portion shall comply with the applicable requirements for that use.

201.3 Temporary and Permanent Structures

These requirements shall apply to temporary and permanent buildings and facilities.
Advisory 201.3 Temporary and Permanent Structures.  Temporary buildings or facilities covered by these requirements include, but are not limited to, reviewing stands, temporary classrooms, bleacher areas, stages, platforms and daises, fixed furniture systems, wall systems, and exhibit areas, temporary banking facilities, and temporary health screening facilities.  Structures and equipment directly associated with the actual processes of construction are not required to be accessible as permitted in 203.2.

Related Code Sections


201 Scoping Requirements, Application
portion shall comply with the applicable requirements for that use ...
2010 ADA Standards > 2 Scoping Requirements > 201 Application
Chapter 1 Application and Administration
2010 ADA Standards > 1 Application and Administration
202.3.2 Scoping Requirements, Extent of Application
An alteration of an existing element, space, or area of a building or facility shall not impose a requirement for accessibility greater than required ...
2010 ADA Standards > 2 Scoping Requirements > 202 Existing Buildings and Facilities > 202.3 Alterations > 202.3.2 Extent of Application
408 Accessible Routes, Limited-Use / Limited-Application Elevators
Limited-use/limited-application elevators shall comply with 408 and with ASME A17.1 (incorporated by reference, see "Referenced Standards" in Chapter ...
2010 ADA Standards > 4 Accessible Routes > 408 Limited-Use / Limited-Application Elevators
101 Application and Administration, Purpose
This document contains scoping and technical requirements for accessibility to sites, facilities, buildings, and elements by individuals ...
2010 ADA Standards > 1 Application and Administration > 101 Purpose
Help Contact Us Privacy Terms
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
Code Compare
Code Compare
Highlight differences between any two building codes.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL PRICING