§40-37 Appliances in Sleeping Rooms
JUMP TO FULL CODE CHAPTER
(a) Gas-fueled water heaters shall not be installed in a room occupied for sleeping purposes, in bathrooms, or in any occupied room normally kept closed.
(b) It shall be unlawful to install a gas-fueled space heater in a room occupied for sleeping purposes except when the space heater is so designed, installed and operated for it:
(1) Obtains combustion air directly from the outside of the building or through a duct leading to the outside.
(2) It vents directly to space outside of the building other than an inner court, or is connected through a flue or outlet pipe with an outside chimney which conforms with the requirements of Subchapter 15 of Chapter 1 of Title 27 of the Administrative Code (Building Code). A flue in an existing brick chimney may be used if it is in good condition and tests show that it will provide adequate draft.
Related Code Sections
303.3 General Regulations, Prohibited Locations
Appliances shall not be located in, or obtain combustion air from, any of the following rooms or spaces: 1. Sleeping rooms ...
NYC Fuel Gas Code 2008 > 3 General Regulations > 303 Appliance Location > 303.3 Prohibited Locations
303.3 General Regulations, Prohibited Locations
Appliances shall not be located in sleeping rooms, bathrooms, toilet rooms, storage closets or surgical rooms, or in a space that opens only ...
NYC Mechanical Code 2014 > 3 General Regulations > 303 Equipment and Appliance Location > 303.3 Prohibited Locations
303.3 General Regulations, Prohibited Locations
Appliances shall not be located in sleeping rooms, bathrooms, toilet rooms, storage closets or surgical rooms, or in a space that opens only ...
NYC Fuel Gas Code 2014 > 3 General Regulations > 303 Appliance Location > 303.3 Prohibited Locations
Appendix A Selected Rules of the Department of Buildings [PDF] (page 5)
§40-34 Capacity of Water Heaters §40-35 Shut-Off Devices §40-36 Gas Piping §40-37 Appliances in Sleeping Rooms §40-38 Clearances from Combustible ...
Appendix A Selected Rules of the Department of Buildings [PDF] (page 119)
piping supplying gas to the apartment. §40-37 Appliances in Sleeping Rooms. (a) Gas-fueled water heaters shall not be installed in a room occupied ...