// CODE SNIPPET

Section G2406 (303) Appliance Location

Residential Code 2015 of Utah > 24 Fuel Gas > G2406 (303) Appliance Location
JUMP TO FULL CODE CHAPTER

G2406.1 (303.1) General

Appliances shall be located as required by this section, specific requirements elsewhere in this code and the conditions of the equipment and appliance listing.

G2406.2 (303.3) Prohibited Locations

Appliances shall not be located in sleeping rooms, bathrooms, toilet rooms, storage closets or surgical rooms, or in a space that opens only into such rooms or spaces, except where the installation complies with one of the following:

1. The appliance is a direct-vent appliance installed in accordance with the conditions of the listing and the manufacturer's instructions.

2. Vented room heaters, wall furnaces, vented decorative appliances, vented gas fireplaces, vented gas fireplace heaters and decorative appliances for installation in vented solid fuel-burning fireplaces are installed in rooms that meet the required volume criteria of Section G2407.5.

3. A single wall-mounted unvented room heater is installed in a bathroom and such unvented room heater is equipped as specified in Section G2445.6 and has an input rating not greater than 6,000 Btu/h (1.76 kW). The bathroom shall meet the required volume criteria of Section G2407.5.

4. A single wall-mounted unvented room heater is installed in a bedroom and such unvented room heater is equipped as specified in Section G2445.6 and has an input rating not greater than 10,000 Btu/h (2.93 kW). The bedroom shall meet the required volume criteria of Section G2407.5.

5. The appliance is installed in a room or space that opens only into a bedroom or bathroom, and such room or space is used for no other purpose and is provided with a solid weather-stripped door equipped with an approved self-closing device. All combustion air shall be taken directly from the outdoors in accordance with Section G2407.6.

G2406.3 (303.6) Outdoor Locations

Appliances installed in outdoor locations shall be either listed for outdoor installation or provided with protection from outdoor environmental factors that influence the operability, durability and safety of the appliance.
Share URL

Copy and paste the link below into emails, chats or browsers.

Copy

You can also copy or bookmark the link from your browser's address bar.

Related Code Sections


Section G2406 Fuel Gas, (303) Appliance Location
Appliances shall be located as required by this section, specific requirements elsewhere in this code and the conditions of the equipment ...
Residential Code 2015 of Utah > 24 Fuel Gas > G2406 (303) Appliance Location
Section 303 General Regulations, (IFGC) Appliance Location
Appliances shall be located as required by this section, specific requirements elsewhere in this code and the conditions of the equipment ...
Fuel Gas Code 2018 of Utah > 3 General Regulations > 303 (IFGC) Appliance Location
Section 303 General Regulations, Equipment and Appliance Location
Equipment and appliances shall be located as required by this section, specific requirements elsewhere in this code and the conditions ...
Mechanical Code 2015 of Utah > 3 General Regulations > 303 Equipment and Appliance Location
Section 303 General Regulations, Equipment and Appliance Location
Equipment and appliances shall be located as required by this section, specific requirements elsewhere in this code and the conditions ...
Mechanical Code 2018 of Utah > 3 General Regulations > 303 Equipment and Appliance Location
Section 303 General Regulations, (IFGC) Appliance Location
Appliances shall be located as required by this section, specific requirements elsewhere in this code and the conditions of the equipment ...
Fuel Gas Code 2015 of Utah > 3 General Regulations > 303 (IFGC) Appliance Location
About UpCodes

UpCodes provides an intuitive resource to navigate building regulations.

Codes are organized by jurisdiction to help you understand which regulations apply to your project.


Find Your Codes
COMPANY INFO About Free Law Contact Careers Terms Privacy Press Kit
CATEGORY General New York City New York State California Codes Building Codes Online
PREMIUM Features Pricing Sign Up Log In
CODES IBC 2015 IRC 2015 IPC 2015 California Building Code 2016 Popular Sections

FOLLOW US