// CODE SNIPPET
Subpart I App D - Test Methods and Procedures for Personal Fall Protection Systems Non-Mandatory Guidelines
JUMP TO FULL CODE CHAPTER
This appendix contains test methods for personal fall protection systems which may be used to determine if they meet the system performance criteria specified in paragraphs (d) and (e) of § 1910.140.
Test methods for personal fall arrest systems (paragraph (d) of § 1910.140).
Test methods for positioning systems (paragraph (e) of § 1910.140).
[81 FR 83004-83005, Nov. 18, 2016]
Appendix D to Subpart I of Part 1910 - Test Methods and Procedures for Personal Fall Protection Systems Non-Mandatory Guidelines
This appendix contains test methods for personal fall protection systems which may be used to determine if they meet the system performance criteria specified in paragraphs (d) and (e) of § 1910.140.
Test methods for personal fall arrest systems (paragraph (d) of § 1910.140).
- General. The following sets forth test procedures for personal fall arrest systems as defined in paragraph (d) of § 1910.140.
- General test conditions.
- Lifelines, lanyards and deceleration devices should be attached to an anchorage and connected to the body harness in the same manner as they would be when used to protect employees.
- Lifelines, lanyards and deceleration devices should be attached to an anchorage and connected to the body harness in the same manner as they would be when used to protect employees.
- The frequency response of the load measuring instrumentation should be 120 Hz.
- The test weight used in the strength and force tests should be a rigid, metal cylindrical or torso-shaped object with a girth of 38 inches plus or minus 4 inches (96 cm plus or minus 10 cm).
- The lanyard or lifeline used to create the free fall distance should be supplied with the system, or in its absence, the least elastic lanyard or lifeline available should be used with the system.
- The test weight for each test should be hoisted to the required level and should be quickly released without having any appreciable motion imparted to it.
- The system's performance should be evaluated, taking into account the range of environmental conditions for which it is designed to be used.
- Following the test, the system need not be capable of further operation.
- Strength test.
- During the testing of all systems, a test weight of 300 pounds plus or minus 3 pounds (136.4 kg plus or minus 1.4 kg) should be used. (See paragraph (b)(4) of this appendix.)
- The test consists of dropping the test weight once. A new unused system should be used for each test.
- For lanyard systems, the lanyard length should be 6 feet plus or minus 2 inches (1.83 m plus or minus 5 cm) as measured from the fixed anchorage to the attachment on the body harness.
- For rope-grab-type deceleration systems, the length of the lifeline above the centerline of the grabbing mechanism to the lifeline's anchorage point should not exceed 2 feet (0.61 m).
- For lanyard systems, for systems with deceleration devices which do not automatically limit free fall distance to 2 feet (0.61 m) or less, and for systems with deceleration devices which have a connection distance in excess of 1 foot (0.3 m) (measured between the centerline of the lifeline and the attachment point to the body harness), the test weight should be rigged to free fall a distance of 7.5 feet (2.3 m) from a point that is 1.5 feet (46 cm) above the anchorage point, to its hanging location (6 feet (1.83 m) below the anchorage). The test weight should fall without interference, obstruction, or hitting the floor or ground during the test. In some cases a non-elastic wire lanyard of sufficient length may need to be added to the system (for test purposes) to create the necessary free fall distance.
- For deceleration device systems with integral lifelines or lanyards that automatically limit free fall distance to 2 feet (0.61 m) or less, the test weight should be rigged to free fall a distance of 4 feet (1.22 m).
- Any weight that detaches from the harness should constitute failure for the strength test.
- Force test.
- General. The test consists of dropping the respective test weight specified in paragraph (d)(2)(i) or (d)(3)(i) of this appendix once. A new, unused system should be used for each test.
- For lanyard systems.
- A test weight of 220 pounds plus or minus three pounds (100 kg plus or minus 1.6 kg) should be used. (See paragraph (b)(4) of this appendix.)
- Lanyard length should be 6 feet plus or minus 2 inches (1.83 m plus or minus 5 cm) as measured from the fixed anchorage to the attachment on the body harness.
- The test weight should fall free from the anchorage level to its hanging location (a total of 6 feet (1.83 m) free fall distance) without interference, obstruction, or hitting the floor or ground during the test.
- For all other systems.
- A test weight of 220 pounds plus or minus 2 pounds (100 kg plus or minus 1.0 kg) should be used. (See paragraph (b)(4) of this appendix.)
- The free fall distance to be used in the test should be the maximum fall distance physically permitted by the system during normal use conditions, up to a maximum free fall distance for the test weight of 6 feet (1.83 m), except as follows:
- For deceleration systems having a connection link or lanyard, the test weight should free fall a distance equal to the connection distance (measured between the centerline of the lifeline and the attachment point to the body harness).
- For deceleration device systems with integral lifelines or lanyards that automatically limit free fall distance to 2 feet (0.61 m) or less, the test weight should free fall a distance equal to that permitted by the system in normal use. (For example, to test a system with a self-retracting lifeline or lanyard, the test weight should be supported and the system allowed to retract the lifeline or lanyard as it would in normal use. The test weight would then be released and the force and deceleration distance measured).
- Failure. A system fails the force test when the recorded maximum arresting force exceeds 2,520 pounds (11.2 kN) when using a body harness.
- Distances. The maximum elongation and deceleration distance should be recorded during the force test.
- Deceleration device tests.
- General. The device should be evaluated or tested under the environmental conditions (such as rain, ice, grease, dirt, and type of lifeline) for which the device is designed.
- Rope-grab-type deceleration devices.
- Devices should be moved on a lifeline 1,000 times over the same length of line a distance of not less than 1 foot (30.5 cm), and the mechanism should lock each time.
- Unless the device is permanently marked to indicate the type of lifelines that must be used, several types (different diameters and different materials), of lifelines should be used to test the device.
- Other self-activating-type deceleration devices. The locking mechanisms of other self-activating-type deceleration devices designed for more than one arrest should lock each of 1,000 times as they would in normal service.
Test methods for positioning systems (paragraph (e) of § 1910.140).
- General. The following sets forth test procedures for positioning systems as defined in paragraph (e) of § 1910.140. The requirements in this appendix for personal fall arrest systems set forth procedures that may be used, along with the procedures listed below, to determine compliance with the requirements for positioning systems.
- Test conditions.
- The fixed anchorage should be rigid and should not have a deflection greater than 0.04 inches (1 mm) when a force of 2,250 pounds (10 kN) is applied.
- For window cleaners' belts, the complete belt should withstand a drop test consisting of a 250 pound (113 kg) weight falling free for a distance of 6 feet (1.83 m). The weight should be a rigid object with a girth of 38 inches plus or minus 4 inches (96 cm plus or minus 10 cm). The weight should be placed in the waistband with the belt buckle drawn firmly against the weight, as when the belt is worn by a window cleaner. One belt terminal should be attached to a rigid anchor and the other terminal should hang free. The terminals should be adjusted to their maximum span. The weight fastened in the freely suspended belt should then be lifted exactly 6 feet (1.83 m) above its "at rest" position and released so as to permit a free fall of 6 feet (1.83 m) vertically below the point of attachment of the terminal anchor. The belt system should be equipped with devices and instrumentation capable of measuring the duration and magnitude of the arrest forces. Failure of the test should consist of any breakage or slippage sufficient to permit the weight to fall free of the system. In addition, the initial and subsequent arresting forces should be measured and should not exceed 2,000 pounds (8.5 kN) for more than 2 milliseconds for the initial impact, or exceed 1,000 pounds (4.5 kN) for the remainder of the arrest time.
- All other positioning systems (except for restraint line systems) should withstand a drop test consisting of a 250 pound (113 kg) weight free falling a distance of 4 feet (1.2 m). The weight must be a rigid object with a girth of 38 inches plus or minus 4 inches (96 cm plus or minus 10 cm). The body belt or harness should be affixed to the test weight as it would be to an employee. The system should be connected to the rigid anchor in the manner that the system would be connected in normal use. The weight should be lifted exactly 4 feet (1.2 m) above its "at rest" position and released so as to permit a vertical free fall of 4 feet (1.2 m). Failure of the system should be indicated by any breakage or slippage sufficient to permit the weight to fall free to the ground.
[81 FR 83004-83005, Nov. 18, 2016]
Related Code Sections
Subpart I Personal Protective Equipment, App D - Test Methods and Procedures for Personal Fall Protection Systems Non-Mandatory Guidelines
Appendix D to Subpart I of Part 1910 - Test Methods and Procedures for Personal Fall Protection Systems Non-Mandatory Guidelines
This ...
OSHA 1910 General Industry > I Personal Protective Equipment > I App D - Test Methods and Procedures for Personal Fall Protection Systems Non-Mandatory Guidelines
Appendix E Hazardous Materials, Training Curriculum Guidelines - (Non-Mandatory)
ratios. For Level C or Level D personal protective equipment the ratio should
be 10 students per instructor. For Level A or Level B personal ...
OSHA 1910 General Industry > H Hazardous Materials > 1910.120 Hazardous Waste Operations and Emergency Response > E Training Curriculum Guidelines - (Non-Mandatory)
Appendix B Toxic and Hazardous Substances, Substance Technical Guidelines for Ethylene Oxide (Non-Mandatory)
of sampling and analysis which has been tested by OSHA for use with EtO. Other available methods are also described in Appendix D. The employer has ...
OSHA 1910 General Industry > Z Toxic and Hazardous Substances > 1910.1047 Ethylene Oxide > B Substance Technical Guidelines for Ethylene Oxide (Non-Mandatory)
Appendix H Toxic and Hazardous Substances, Medical Surveillance Guidelines for Asbestos - Non-Mandatory
of the respiratory system, cardiovascular system, and digestive tract.
Completion of the respiratory disease questionnaire contained in Appendix D.
A ...
OSHA 1910 General Industry > Z Toxic and Hazardous Substances > 1910.1001 Asbestos > H Medical Surveillance Guidelines for Asbestos - Non-Mandatory
1910.140(e)(1)(iii) Personal Protective Equipment,
Positioning systems, including window cleaners' positioning systems, that meet the test methods and procedures in appendix D of this subpart ...
OSHA 1910 General Industry > I Personal Protective Equipment > 1910.140 Personal Fall Protection Systems > 1910.140(e) Positioning Systems > 1910.140(e)(1) System Performance Requirements > 1910.140(e)(1)(iii)