Subpart S App A - Decompression Tables
JUMP TO FULL CODE CHAPTER
[ 44 FR 8577, Feb. 9, 1979; 44 FR 20940, Apr. 6, 1979, as amended at 58 FR 35311, June 30, 1993]
- Explanation. The decompression tables are computed for working chamber pressures from 0 to 14 pounds, and from 14 to 50 pounds per square inch gauge inclusive by 2-pound increments and for exposure times for each pressure extending from one-half to over 8 hours inclusive. Decompressions will be conducted by two or more stages with a maximum of four stages, the latter for a working chamber pressure of 40 pounds per square inch gauge or over.
Stage 1 consists of a reduction in ambient pressure ranging from 10 to a maximum of 16 pounds per square inch, but in no instance will the pressure be reduced below 4 pounds at the end of stage 1. This reduction in pressure in stage 1 will always take place at a rate not greater than 5 pounds per minute.
Further reduction in pressure will take place during stage 2 and subsequent stages as required at a slower rate, but in no event at a rate greater than 1 pound per minute.
Decompression Table No. 1 indicates in the body of the table the total decompression time in minutes for various combinations of working chamber pressure and exposure time.
Decompression Table No. 2 indicates for the same various combinations of working chamber pressure and exposure time the following:
- The number of stages required;
- The reduction in pressure and the terminal pressure for each required stage;
- The time in minutes through which the reduction in pressure is accomplished for each required stage;
- The pressure reduction rate in minutes per pound for each required stage;
Examples | Minutes |
---|---|
Example No. 1: 4 hours working period at 20 pounds gauge. | |
Decompression Table No. 1: 20 pounds for 4 hours, total decompression time | 43 |
Decompression Table No. 2: | |
Stage 1: Reduce pressure from 20 pounds to 4 pounds at the uniform rate of 5 pounds per minute. |
|
Elapsed time stage 1: 16/5 |
3 |
Stage 2 (final stage): Reduce pressure at a uniform rate from 4 pounds to 0-pound gage over a period of 40 minutes. |
|
Rate - 0.10 pound per minute or 10 minutes per pound. |
|
Stage 2 (final) elapsed time |
40 |
Total time |
43 |
Example No. 2: 5-hour working period at 24 pounds gage. | |
Decompression Table No. 1: 24 pounds for 5 hours, total decompression time | 117 |
Decompression Table No. 2: | |
Stage 1: Reduce pressure from 24 pounds to 8 pounds at the uniform rate of 5 pounds per minute. |
|
Elapsed time stage 1: 16/5 |
3 |
Stage 2: Reduce pressure at a uniform rate from 8 pounds to 4 pounds over a period of 4 minutes. Rate, 1 pound per minute elapsed time, stage 2 |
4 |
Transfer men to special decompression chamber maintaining the 4-pound pressure during the transfer operation. |
|
Stage 3 (final stage): In the special decompression chamber, reduce the pressure at a uniform rate from 4 pounds to 0-pound gage over a period of 110 minutes. Rate, 0.037 pound per minute or 27.5 minutes per pound. Stage 3 (final) elapsed time |
110 |
Total time |
117 |
Work pressure p.s.i.g. | Working period hours | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
1/2 | 1 | 11/2 | 2 | 3 | 4 | 5 | 6 | 7 | 8 | Over 8 | |
9 to 12 | 3 | 3 | 3 | 3 | 3 | 3 | 3 | 3 | 3 | 3 | 3 |
14 | 6 | 6 | 6 | 6 | 6 | 6 | 6 | 6 | 16 | 16 | 33 |
16 | 7 | 7 | 7 | 7 | 7 | 7 | 17 | 33 | 48 | 48 | 62 |
18 | 7 | 7 | 7 | 8 | 11 | 17 | 48 | 63 | 63 | 73 | 87 |
20 | 7 | 7 | 8 | 15 | 15 | 43 | 63 | 73 | 83 | 103 | 113 |
22 | 9 | 9 | 16 | 24 | 38 | 68 | 93 | 103 | 113 | 128 | 133 |
24 | 11 | 12 | 123 | 27 | 52 | 92 | 117 | 122 | 127 | 137 | 151 |
26 | 13 | 14 | 29 | 34 | 69 | 104 | 126 | 141 | 142 | 142 | 163 |
28 | 15 | 23 | 31 | 41 | 98 | 127 | 143 | 153 | 153 | 165 | 183 |
30 | 17 | 28 | 38 | 62 | 105 | 143 | 165 | 168 | 178 | 188 | 204 |
32 | 19 | 35 | 43 | 85 | 126 | 163 | 178 | 193 | 203 | 213 | 226 |
34 | 21 | 39 | 58 | 98 | 151 | 178 | 195 | 218 | 223 | 233 | 248 |
36 | 24 | 44 | 63 | 113 | 170 | 198 | 223 | 233 | 243 | 253 | 273 |
38 | 28 | 49 | 73 | 128 | 178 | 203 | 223 | 238 | 253 | 263 | 278 |
40 | 31 | 49 | 84 | 143 | 183 | 213 | 233 | 248 | 258 | 278 | 288 |
42 | 37 | 56 | 102 | 144 | 189 | 215 | 245 | 260 | 263 | 268 | 293 |
44 | 43 | 64 | 118 | 154 | 199 | 234 | 254 | 264 | 269 | 269 | 293 |
46 | 44 | 74 | 139 | 171 | 214 | 244 | 269 | 274 | 289 | 299 | 318 |
48 | 51 | 89 | 144 | 189 | 229 | 269 | 299 | 309 | 319 | 319 | |
50 | 58 | 94 | 164 | 209 | 249 | 279 | 309 | 329 |
Working chamber pressure p.s.i.g. | Working period hours | Decompression data | |||||
---|---|---|---|---|---|---|---|
Stage No. | Pressure reduc. p.s.i.g. | Time in stage minutes | Pressure reduc. rate Min/pound | Total time decompress minutes | |||
From | To | ||||||
14 | 1/2 | 1 | 14 | 4 | 2 | 0.20 | 6 |
2 | 4 | 0 | 4 | 1.00 | 6 | ||
1 | 1 | 14 | 4 | 2 | 0.20 | 6 | |
2 | 4 | 0 | 4 | 1.00 | 6 | ||
1 1/2 | 1 | 14 | 4 | 2 | 0.20 | 6 | |
2 | 4 | 0 | 4 | 1.00 | 6 | ||
2 | 1 | 14 | 4 | 2 | 0.20 | 6 | |
2 | 4 | 0 | 4 | 1.00 | 6 | ||
3 | 1 | 14 | 4 | 2 | 0.20 | 6 | |
2 | 4 | 0 | 4 | 1.00 | 6 | ||
4 | 1 | 14 | 0 | 2 | 0.20 | 6 | |
2 | 4 | 0 | 4 | 1.00 | 6 | ||
5 | 1 | 14 | 4 | 2 | 0.20 | 6 | |
2 | 4 | 0 | 4 | 1.00 | 6 | ||
6 | 1 | 14 | 4 | 2 | 0.20 | ||
2 | 4 | 0 | 4 | 1.00 | 6 | ||
7 | 1 | 14 | 4 | 2 | 0.20 | ||
2 | 4 | 0 | 14 | 3.50 | 16 | ||
8 | 1 | 14 | 4 | 2 | 0.20 | ||
2 | 4 | 0 | 14 | 3.50 | 16 | ||
Over 8 | 1 | 14 | 4 | 2 | 0.20 | ||
2 | 4 | 0 | 14 | 3.50 | 32 | ||
16 | 1/2 | 1 | 16 | 4 | 3 | 0.20 | |
2 | 4 | 0 | 4 | 1.00 | 7 | ||
1 | 1 | 16 | 4 | 3 | 0.20 | 7 | |
2 | 4 | 0 | 4 | 1.00 | 7 | ||
1 1/2 | 1 | 16 | 4 | 3 | 0.20 | ||
2 | 4 | 0 | 4 | 1.00 | 7 | ||
2 | 1 | 16 | 4 | 3 | 0.20 | ||
2 | 4 | 0 | 4 | 1.00 | 7 | ||
3 | 1 | 16 | 4 | 3 | 0.20 | ||
2 | 4 | 0 | 4 | 1.00 | 7 | ||
4 | 1 | 14 | 4 | 3 | 0.20 | ||
2 | 4 | 0 | 4 | 1.00 | 7 | ||
5 | 1 | 14 | 4 | 3 | 0.20 | 7 | |
2 | 4 | 0 | 4 | 3.50 | 17 | ||
6 | 1 | 14 | 4 | 3 | 0.20 | ||
2 | 4 | 0 | 30 | 7.50 | 33 | ||
7 | 1 | 14 | 4 | 3 | 0.20 | ||
2 | 4 | 0 | 45 | 11.25 | 48 | ||
8 | 1 | 14 | 4 | 3 | 0.20 | ||
2 | 4 | 0 | 45 | 11.25 | 48 | ||
Over 8 | 1 | 14 | 4 | 3 | 0.20 | ||
2 | 4 | 0 | 60 | 15.00 | 63 | ||
18 | 1/2 | 1 | 18 | 4 | 3 | 0.20 | |
2 | 4 | 0 | 4 | 1.00 | 7 | ||
1 | 1 | 18 | 4 | 3 | 0.20 | ||
2 | 4 | 0 | 4 | 1.00 | 7 | ||
1 1/2 | 1 | 18 | 4 | 3 | 0.20 | ||
2 | 4 | 0 | 4 | 1.00 | 7 | ||
2 | 1 | 18 | 4 | 3 | 0.20 | ||
2 | 4 | 0 | 5 | 1.25 | 8 | ||
3 | 1 | 18 | 4 | 3 | 0.20 | ||
2 | 4 | 0 | 8 | 2.00 | 11 | ||
4 | 1 | 18 | 4 | 3 | 0.20 | ||
2 | 4 | 0 | 14 | 3.50 | 17 | ||
5 | 1 | 18 | 4 | 3 | 0.20 | ||
2 | 4 | 0 | 45 | 11.25 | 48 | ||
6 | 1 | 18 | 4 | 3 | 0.20 | ||
2 | 4 | 0 | 60 | 15.00 | 63 | ||
7 | 1 | 18 | 4 | 3 | 0.20 | ||
2 | 4 | 0 | 60 | 15.00 | 63 | ||
8 | 1 | 18 | 4 | 3 | 0.20 | ||
2 | 4 | 0 | 70 | 17.50 | 73 | ||
Over 8 | 1 | 18 | 4 | 3 | 0.20 | ||
2 | 4 | 0 | 84 | 21.00 | 87 | ||
20 | 1/2 | 1 | 20 | 4 | 3 | 0.20 | |
2 | 4 | 0 | 4 | 1.00 | 7 | ||
1 | 1 | 20 | 4 | 3 | 0.20 | ||
2 | 4 | 0 | 4 | 1.00 | 7 | ||
1 1/2 | 1 | 20 | 4 | 3 | 0.20 | ||
2 | 4 | 0 | 5 | 1.25 | 8 | ||
2 | 1 | 20 | 4 | 3 | 0.20 | ||
2 | 4 | 0 | 12 | 3.00 | 15 | ||
3 | 1 | 20 | 4 | 3 | 0.20 | ||
2 | 4 | 0 | 12 | 3.00 | 15 | ||
4 | 1 | 20 | 4 | 3 | 0.20 | ||
2 | 4 | 0 | 40 | 10.00 | 43 | ||
5 | 1 | 20 | 4 | 3 | 0.20 | ||
2 | 4 | 0 | 60 | 15.00 | 63 | ||
6 | 1 | 20 | 4 | 3 | 0.20 | ||
2 | 4 | 0 | 70 | 17.50 | 73 | ||
7 | 1 | 20 | 4 | 3 | 0.20 | ||
2 | 4 | 0 | 80 | 20.00 | 83 | ||
8 | 1 | 20 | 4 | 3 | 0.20 | ||
2 | 4 | 0 | 100 | 25.00 | 103 | ||
Over 8 | 1 | 20 | 4 | 3 | 0.20 | ||
2 | 4 | 0 | 110 | 27.50 | 113 | ||
22 | 1/2 | 1 | 22 | 6 | 3 | 0.20 | |
2 | 6 | 0 | 6 | 1.00 | 9 | ||
1 | 1 | 22 | 6 | 3 | 0.20 | ||
2 | 6 | 0 | 6 | 1.00 | 9 | ||
1 1/2 | 1 | 22 | 6 | 3 | 0.20 | ||
2 | 6 | 0 | 13 | 2.20 | 16 | ||
2 | 1 | 22 | 6 | 3 | 0.20 | ||
2 | 6 | 0 | 21 | 3.50 | 24 | ||
3 | 1 | 22 | 6 | 3 | 0.20 | ||
2 | 6 | 0 | 35 | 5.85 | 38 | ||
4 | 1 | 22 | 6 | 3 | 0.20 | ||
2 | 6 | 0 | 65 | 10.83 | 68 | ||
5 | 1 | 22 | 6 | 3 | 0.20 | ||
2 | 6 | 0 | 90 | 15.00 | 93 | ||
6 | 1 | 22 | 6 | 3 | 0.20 | ||
2 | 4 | 0 | 100 | 16.67 | 103 | ||
7 | 1 | 22 | 6 | 3 | 0.20 | ||
2 | 6 | 0 | 110 | 18.35 | 113 | ||
8 | 1 | 22 | 6 | 3 | 0.20 | ||
2 | 6 | 0 | 125 | 20.80 | 128 | ||
Over 8 | 1 | 22 | 6 | 3 | 0.20 | ||
2 | 6 | 0 | 130 | 21.70 | 133 | ||
24 | 1/2 | 1 | 24 | 8 | 3 | 0.20 | |
2 | 8 | 4 | 4 | 1.00 | |||
3 | 4 | 0 | 4 | 1.00 | 11 | ||
1 | 1 | 24 | 8 | 3 | 0.20 | ||
2 | 8 | 4 | 4 | 1.00 | |||
3 | 4 | 0 | 5 | 1.25 | 12 | ||
1 1/2 | 1 | 24 | 8 | 3 | 0.20 | ||
2 | 8 | 4 | 4 | 1.00 | |||
3 | 4 | 0 | 16 | 4.00 | 23 | ||
2 | 1 | 24 | 8 | 3 | 0.20 | ||
2 | 8 | 4 | 4 | 1.00 | |||
3 | 4 | 0 | 20 | 5.00 | 27 | ||
3 | 1 | 24 | 8 | 3 | 0.20 | ||
2 | 8 | 4 | 4 | 1.00 | |||
3 | 4 | 0 | 45 | 11.25 | 52 | ||
4 | 1 | 24 | 8 | 3 | 0.20 | ||
2 | 8 | 4 | 4 | 1.00 | |||
3 | 4 | 0 | 85 | 21.25 | 92 | ||
5 | 1 | 24 | 8 | 3 | 0.20 | ||
2 | 8 | 4 | 4 | 1.00 | |||
3 | 4 | 0 | 110 | 27.50 | 117 | ||
6 | 1 | 24 | 8 | 3 | 0.20 | ||
2 | 8 | 4 | 4 | 1.00 | |||
3 | 4 | 0 | 115 | 28.80 | 122 | ||
7 | 1 | 24 | 8 | 3 | 0.20 | ||
2 | 8 | 4 | 4 | 1.00 | |||
3 | 4 | 0 | 120 | 30.00 | 127 | ||
8 | 1 | 24 | 8 | 3 | 0.20 | ||
2 | 8 | 4 | 4 | 1.00 | |||
3 | 4 | 0 | 130 | 32.50 | 137 | ||
Over 8 | 1 | 24 | 8 | 3 | 0.20 | ||
2 | 8 | 4 | 8 | 2.00 | |||
3 | 4 | 0 | 140 | 35.00 | 151 | ||
26 | 1/2 | 1 | 26 | 10 | 3 | 0.20 | |
2 | 10 | 4 | 6 | 1.00 | |||
3 | 4 | 0 | 4 | 1.00 | 13 | ||
1 | 1 | 26 | 10 | 3 | 0.20 | ||
2 | 10 | 4 | 6 | 1.00 | |||
3 | 4 | 0 | 5 | 1.25 | 14 | ||
1 1/2 | 1 | 26 | 10 | 3 | 0.20 | ||
2 | 10 | 4 | 6 | 1.00 | |||
3 | 4 | 0 | 20 | 5.00 | 29 | ||
2 | 1 | 26 | 10 | 3 | 0.20 | ||
2 | 10 | 4 | 6 | 1.00 | |||
3 | 4 | 0 | 25 | 6.25 | 34 | ||
3 | 1 | 26 | 10 | 3 | 0.20 | ||
2 | 10 | 4 | 6 | 1.00 | |||
3 | 4 | 0 | 60 | 15.00 | 69 | ||
4 | 1 | 26 | 10 | 3 | 0.20 | ||
2 | 10 | 4 | 6 | 1.00 | |||
3 | 4 | 0 | 95 | 23.75 | 104 | ||
5 | 1 | 26 | 10 | 3 | 0.20 | ||
2 | 10 | 4 | 8 | 1.33 | |||
3 | 4 | 0 | 115 | 28.80 | 126 | ||
6 | 1 | 26 | 10 | 3 | 0.20 | ||
2 | 10 | 4 | 8 | 1.33 | |||
3 | 4 | 0 | 130 | 32.50 | 141 | ||
7 | 1 | 26 | 10 | 3 | 0.20 | ||
2 | 10 | 4 | 9 | 1.50 | |||
3 | 4 | 0 | 130 | 32.50 | 142 | ||
8 | 1 | 26 | 10 | 3 | 0.20 | ||
2 | 10 | 4 | 9 | 1.50 | |||
3 | 4 | 0 | 130 | 32.50 | 142 | ||
Over 8 | 1 | 26 | 10 | 3 | 0.20 | ||
2 | 10 | 4 | 30 | 5.00 | |||
3 | 4 | 0 | 30 | 32.50 | 163 | ||
28 | 1/2 | 1 | 28 | 12 | 3 | 0.20 | |
2 | 12 | 4 | 8 | 1.00 | |||
3 | 4 | 0 | 4 | 1.00 | 15 | ||
1 | 1 | 28 | 12 | 3 | 0.20 | ||
2 | 12 | 4 | 8 | 1.00 | |||
3 | 4 | 0 | 12 | 3.00 | 23 | ||
1 1/2 | 1 | 28 | 12 | 3 | 0.20 | ||
2 | 12 | 4 | 8 | 1.00 | |||
3 | 4 | 0 | 20 | 5.00 | 31 | ||
2 | 1 | 28 | 12 | 3 | 0.20 | ||
2 | 12 | 4 | 8 | 1.00 | |||
3 | 4 | 0 | 30 | 7.50 | 41 | ||
3 | 1 | 28 | 12 | 3 | 0.20 | ||
2 | 12 | 4 | 10 | 1.25 | |||
3 | 4 | 0 | 85 | 21.20 | 98 | ||
4 | 1 | 28 | 12 | 3 | 0.20 | ||
2 | 12 | 4 | 14 | 1.75 | |||
3 | 4 | 0 | 110 | 27.50 | 127 | ||
5 | 1 | 28 | 12 | 3 | 0.20 | ||
2 | 12 | 4 | 20 | 2.50 | |||
3 | 4 | 0 | 120 | 30.00 | 143 | ||
6 | 1 | 28 | 12 | 3 | 0.20 | ||
2 | 12 | 4 | 20 | 2.50 | |||
3 | 4 | 0 | 130 | 32.50 | 153 | ||
7 | 1 | 28 | 12 | 3 | 0.20 | ||
2 | 12 | 4 | 20 | 2.50 | |||
3 | 4 | 0 | 120 | 32.50 | 153 | ||
8 | 1 | 28 | 12 | 3 | 0.20 | ||
2 | 12 | 4 | 32 | 4.00 | |||
3 | 4 | .0 | 130 | 32.50 | 165 | ||
Over 8 | 1 | 28 | 12 | 3 | 0.20 | ||
2 | 12 | 4 | 50 | 6.25 | |||
3 | 4 | 0 | 130 | 32.50 | 183 | ||
30 | 1/2 | 1 | 30 | 14 | 3 | 0.20 | |
2 | 14 | 4 | 10 | 1.00 | |||
3 | 4 | 0 | 4 | 1.00 | 17 | ||
1 | 1 | 30 | 14 | 3 | 0.20 | ||
2 | 14 | 4 | 10 | 1.00 | |||
3 | 4 | 0 | 15 | 3.75 | 28 | ||
1 1/2 | 1 | 30 | 14 | 3 | 0.20 | ||
2 | 14 | 4 | 10 | 1.00 | |||
3 | 4 | 0 | 25 | 6.25 | 38 | ||
2 | 1 | 30 | 14 | 3 | 0.20 | ||
2 | 14 | 4 | 14 | 1.40 | |||
3 | 4 | 0 | 45 | 11.25 | 62 | ||
3 | 1 | 30 | 14 | 3 | 0.20 | ||
2 | 14 | 4 | 17 | 1.70 | |||
3 | 4 | 0 | 85 | 21.20 | 105 | ||
4 | 1 | 30 | 14 | 3 | 0.20 | ||
2 | 14 | 4 | 30 | 3.00 | |||
3 | 4 | 0 | 110 | 27.50 | 143 | ||
5 | 1 | 30 | 14 | 3 | 0.20 | ||
2 | 14 | 4 | 35 | 3.50 | |||
3 | 4 | 0 | 130 | 32.50 | 165 | ||
6 | 1 | 30 | 14 | 3 | 0.20 | ||
2 | 14 | 4 | 35 | 3.50 | |||
3 | 4 | 0 | 130 | 32.50 | 168 | ||
7 | 1 | 30 | 14 | 3 | 0.20 | ||
2 | 14 | 4 | 45 | 4.50 | |||
3 | 4 | 0 | 130 | 32.50 | 178 | ||
8 | 1 | 30 | 14 | 3 | 0.20 | ||
2 | 14 | 4 | 55 | 5.50 | |||
3 | 4 | 0 | 130 | 32.50 | 188 | ||
Over 8 | 1 | 30 | 14 | 3 | 0.20 | ||
2 | 14 | 4 | 71 | 7.10 | |||
3 | 4 | 0 | 130 | 32.50 | 204 | ||
32 | 1/2 | 1 | 32 | 16 | 3 | 0.20 | |
2 | 16 | 4 | 12 | 1.00 | |||
3 | 4 | 0 | 4 | 1.00 | 19 | ||
1 | 1 | 32 | 16 | 3 | 0.20 | ||
2 | 16 | 4 | 12 | 1.00 | |||
3 | 4 | 0 | 20 | 5.00 | 35 | ||
1 1/2 | 1 | 32 | 16 | 3 | 0.20 | ||
2 | 16 | 4 | 15 | 1.25 | |||
3 | 4 | 0 | 25 | 6.25 | 43 | ||
2 | 1 | 32 | 16 | 3 | 0.20 | ||
2 | 16 | 4 | 22 | 1.83 | |||
3 | 4 | 0 | 60 | 15.00 | 85 | ||
3 | 1 | 32 | 16 | 3 | 0.20 | ||
2 | 16 | 4 | 28 | 2.33 | |||
3 | 4 | 0 | 95 | 23.75 | 126 | ||
4 | 1 | 32 | 16 | 3 | 0.20 | ||
2 | 16 | 4 | 40 | 3.33 | |||
3 | 4 | 0 | 120 | 30.00 | 163 | ||
5 | 1 | 32 | 16 | 3 | 0.20 | ||
2 | 16 | 4 | 45 | 3.75 | |||
3 | 4 | 0 | 130 | 32.50 | 178 | ||
6 | 1 | 32 | 16 | 3 | 0.20 | ||
2 | 16 | 4 | 60 | 5.00 | |||
3 | 4 | 0 | 130 | 32.50 | 193 | ||
7 | 1 | 32 | 16 | 3 | 0.20 | ||
2 | 16 | 4 | 80 | 6.67 | |||
3 | 4 | 0 | 130 | 32.50 | 203 | ||
8 | 1 | 32 | 16 | 3 | 0.20 | ||
2 | 16 | 4 | 80 | 6.67 | |||
3 | 4 | 0 | 130 | 32.50 | 213 | ||
Over 8 | 1 | 32 | 16 | 3 | 0.20 | ||
2 | 16 | 4 | 93 | 7.75 | |||
3 | 4 | 0 | 130 | 32.50 | 226 | ||
34 | 1/2 | 1 | 34 | 18 | 3 | 0.20 | |
2 | 18 | 4 | 14 | 1.00 | |||
3 | 4 | 0 | 4 | 1.00 | 21 | ||
1 | 1 | 34 | 18 | 3 | 0.20 | ||
2 | 18 | 4 | 14 | 1.00 | |||
3 | 4 | 0 | 22 | 5.50 | 39 | ||
1 1/2 | 1 | 34 | 18 | 3 | 0.20 | ||
2 | 18 | 4 | 25 | 1.80 | |||
3 | 4 | 0 | 30 | 7.50 | 58 | ||
2 | 1 | 34 | 18 | 3 | 0.20 | ||
2 | 18 | 4 | 35 | 2.50 | |||
3 | 4 | 0 | 60 | 15.00 | 98 | ||
3 | 1 | 34 | 18 | 3 | 0.20 | ||
2 | 18 | 4 | 43 | 3.10 | |||
3 | 4 | 0 | 105 | 26.25 | 151 | ||
4 | 1 | 34 | 18 | 3 | 0.20 | ||
2 | 18 | 4 | 55 | 3.93 | |||
3 | 4 | 0 | 120 | 30.00 | 178 | ||
5 | 1 | 34 | 18 | 3 | 0.20 | ||
2 | 18 | 4 | 62 | 4.43 | |||
3 | 4 | 0 | 130 | 32.50 | 195 | ||
6 | 1 | 34 | 18 | 3 | 0.20 | ||
2 | 18 | 4 | 85 | 6.07 | |||
3 | 4 | 0 | 130 | 32.50 | 218 | ||
7 | 1 | 34 | 18 | 3 | 0.20 | ||
2 | 18 | 4 | 90 | 6.43 | |||
3 | 4 | 0 | 130 | 32.50 | 223 | ||
8 | 1 | 34 | 18 | 3 | 0.20 | ||
2 | 18 | 4 | 100 | 7.15 | |||
3 | 4 | 0 | 130 | 32.50 | 233 | ||
Over 8 | 1 | 34 | 18 | 3 | 0.20 | ||
2 | 18 | 4 | 115 | 8.23 | |||
3 | 4 | 0 | 130 | 32.50 | 248 | ||
36 | 1/2 | 1 | 36 | 20 | 3 | 0.20 | |
2 | 20 | 4 | 16 | 1.00 | |||
3 | 4 | 0 | 5 | 1.25 | 24 | ||
1 | 1 | 36 | 20 | 3 | 0.20 | ||
2 | 20 | 4 | 16 | 1.00 | |||
3 | 4 | 0 | 25 | 6.25 | 44 | ||
1 1/2 | 1 | 36 | 20 | 3 | 0.20 | ||
2 | 20 | 4 | 30 | 1.88 | |||
3 | 4 | 0 | 30 | 7.50 | 63 | ||
2 | 1 | 36 | 20 | 3 | 0.20 | ||
2 | 20 | 4 | 40 | 2.50 | |||
3 | 4 | 0 | 70 | 17.50 | 113 | ||
3 | 1 | 36 | 20 | 3 | 0.20 | ||
2 | 20 | 4 | 52 | 3.25 | |||
3 | 4 | 0 | 115 | 28.75 | 170 | ||
4 | 1 | 36 | 20 | 3 | 0.20 | ||
2 | 20 | 4 | 65 | 4.06 | |||
3 | 4 | 0 | 130 | 32.50 | 198 | ||
5 | 1 | 36 | 20 | 3 | 0.20 | ||
2 | 20 | 4 | 90 | 5.63 | |||
3 | 4 | 0 | 130 | 32.50 | 223 | ||
6 | 1 | 36 | 20 | 3 | 0.20 | ||
2 | 20 | 4 | 100 | 6.25 | |||
3 | 4 | 0 | 130 | 32.50 | 233 | ||
7 | 1 | 36 | 20 | 3 | 0.20 | ||
2 | 20 | 4 | 110 | 6.88 | |||
3 | 4 | 0 | 130 | 32.50 | 243 | ||
8 | 1 | 36 | 20 | 3 | 0.20 | ||
2 | 20 | 4 | 120 | 7.50 | |||
3 | 4 | 0 | 130 | 32.50 | 253 | ||
Over 8 | 1 | 36 | 20 | 3 | 0.20 | ||
2 | 20 | 4 | 140 | 8.75 | |||
3 | 4 | 0 | 130 | 32.50 | 273 | ||
38 | 1/2 | 1 | 38 | 22 | 3 | 0.20 | |
2 | 22 | 6 | 16 | 1.00 | |||
3 | 4 | 0 | 9 | 1.50 | 28 | ||
1 | 1 | 38 | 22 | 3 | 0.20 | ||
2 | 22 | 6 | 16 | 1.00 | |||
3 | 6 | 0 | 30 | 5.00 | 49 | ||
1 1/2 | 1 | 38 | 22 | 3 | 0.20 | ||
2 | 22 | 6 | 20 | 1.25 | |||
3 | 6 | 0 | 50 | 8.34 | 73 | ||
2 | 1 | 38 | 22 | 3 | 0.20 | ||
2 | 22 | 6 | 30 | 1.88 | |||
3 | 6 | 0 | 95 | 15.83 | 128 | ||
3 | 1 | 28 | 22 | 3 | 0.20 | ||
2 | 22 | 6 | 35 | 2.19 | |||
3 | 6 | 0 | 140 | 23.35 | 178 | ||
4 | 1 | 38 | 22 | 3 | 0.20 | ||
2 | 22 | 6 | 50 | 3.12 | |||
3 | 6 | 0 | 150 | 25.00 | 203 | ||
5 | 1 | 38 | 22 | 3 | 0.20 | ||
2 | 22 | 6 | 55 | 3.44 | |||
3 | 6 | 0 | 165 | 27.50 | 223 | ||
6 | 1 | 38 | 22 | 3 | 0.20 | ||
2 | 22 | 6 | 70 | 4.38 | |||
3 | 6 | 0 | 165 | 27.50 | 238 | ||
7 | 1 | 38 | 22 | 3 | 0.20 | ||
2 | 22 | 6 | 85 | 5.32 | |||
3 | 6 | 0 | 165 | 27.50 | 253 | ||
8 | 1 | 38 | 22 | 3 | 0.20 | ||
2 | 22 | 6 | 95 | 5.93 | |||
3 | 6 | 0 | 165 | 27.50 | 263 | ||
Over 8 | 1 | 38 | 22 | 3 | 0.20 | ||
2 | 22 | 6 | 110 | 6.88 | |||
3 | 6 | 0 | 165 | 27.50 | 278 | ||
40 | 1/2 | 1 | 40 | 24 | 3 | 0.20 | |
2 | 24 | 8 | 16 | 1.00 | |||
3 | 8 | 4 | 4 | 1.00 | |||
4 | 4 | 0 | 8 | 2.00 | 31 | ||
1 | 1 | 40 | 24 | 3 | 0.20 | ||
2 | 24 | 8 | 16 | 1.00 | |||
3 | 8 | 4 | 5 | 1.25 | |||
4 | 4 | 0 | 25 | 6.25 | 49 | ||
1 1/2 | 1 | 40 | 24 | 3 | 0.20 | ||
2 | 24 | 8 | 16 | 1.00 | |||
3 | 8 | 4 | 20 | 5.00 | |||
4 | 4 | 0 | 45 | 11.25 | 84 | ||
2 | 2 | 40 | 24 | 3 | 0.20 | ||
1 | 24 | 8 | 25 | 1.56 | |||
3 | 8 | 4 | 20 | 5.00 | |||
4 | 4 | 0 | 95 | 23.75 | 143 | ||
3 | 1 | 40 | 24 | 3 | 0.20 | ||
2 | 24 | 8 | 30 | 1.88 | |||
3 | 8 | 4 | 30 | 7.50 | |||
4 | 4 | 0 | 120 | 30.00 | 183 | ||
4 | 1 | 40 | 24 | 3 | 0.20 | ||
2 | 24 | 8 | 45 | 2.81 | |||
3 | 8 | 4 | 35 | 8.75 | |||
4 | 4 | 0 | 130 | 32.50 | 213 | ||
5 | 1 | 40 | 24 | 3 | 0.20 | ||
2 | 24 | 8 | 47 | 2.94 | |||
3 | 8 | 4 | 53 | 13.25 | |||
4 | 4 | 0 | 130 | 32.50 | 233 | ||
6 | 1 | 40 | 24 | 3 | 0.20 | ||
2 | 24 | 8 | 55 | 3.44 | |||
3 | 8 | 4 | 60 | 15.00 | |||
4 | 4 | 0 | 130 | 32.50 | 248 | ||
7 | 1 | 40 | 24 | 3 | 0.20 | ||
2 | 24 | 8 | 65 | 4.06 | |||
3 | 8 | 4 | 60 | 15.00 | |||
4 | 4 | 0 | 130 | 32.50 | 285 | ||
8 | 1 | 40 | 24 | 3 | 0.20 | ||
2 | 24 | 8 | 60 | 15.00 | |||
3 | 8 | 4 | 60 | 15.00 | |||
4 | 4 | 0 | 130 | 32.50 | 268 | ||
Over 8 | 1 | 40 | 24 | 3 | 0.20 | ||
2 | 24 | 8 | 95 | 5.93 | |||
3 | 8 | 4 | 60 | 15.00 | |||
4 | 4 | 0 | 130 | 32.50 | 288 | ||
42 | 1/2 | 1 | 42 | 26 | 3 | 0.20 | |
2 | 26 | 10 | 16 | 1.00 | |||
3 | 10 | 4 | 6 | 1.00 | |||
4 | 4 | 0 | 12 | 3.00 | 37 | ||
1 | 1 | 42 | 26 | 3 | 0.20 | ||
2 | 26 | 10 | 16 | 1.00 | |||
3 | 10 | 4 | 12 | 2.00 | |||
4 | 4 | 0 | 25 | 6.25 | 56 | ||
1 1/2 | 1 | 42 | 26 | 3 | 0.20 | ||
2 | 26 | 10 | 16 | 1.00 | |||
3 | 10 | 4 | 23 | 3.83 | |||
4 | 4 | 0 | 60 | 15.00 | 102 | ||
2 | 1 | 42 | 26 | 3 | 0.20 | ||
2 | 26 | 10 | 16 | 1.00 | |||
3 | 10 | 4 | 30 | 5.00 | |||
4 | 4 | 0 | 95 | 23.75 | 144 | ||
3 | 1 | 42 | 26 | 3 | 0.20 | ||
2 | 26 | 10 | 16 | 1.00 | |||
3 | 10 | 4 | 50 | 8.34 | |||
4 | 4 | 0 | 120 | 30.00 | 189 | ||
4 | 1 | 42 | 26 | 3 | 0.20 | ||
2 | 26 | 10 | 17 | 1.06 | |||
3 | 10 | 4 | 65 | 10.83 | |||
4 | 4 | 0 | 130 | 32.50 | 215 | ||
5 | 1 | 42 | 26 | 3 | 0.20 | ||
2 | 26 | 10 | 27 | 169 | |||
3 | 10 | 4 | 85 | 14.18 | |||
4 | 4 | 0 | 130 | 32.50 | 245 | ||
6 | 1 | 42 | 26 | 3 | 0.20 | ||
2 | 26 | 10 | 27 | 1.69 | |||
3 | 10 | 4 | 100 | 16.67 | |||
4 | 4 | 0 | 130 | 32.50 | 260 | ||
7 | 1 | 42 | 26 | 3 | 0.20 | ||
2 | 26 | 10 | 30 | 1.88 | |||
3 | 10 | 4 | 100 | 16.67 | |||
4 | 4 | 0 | 130 | 32.50 | 263 | ||
8 | 1 | 42 | 26 | 3 | 0.20 | ||
2 | 26 | 10 | 35 | 2.19 | |||
3 | 10 | 4 | 100 | 16.67 | |||
4 | 4 | 0 | 130 | 32.50 | 268 | ||
Over 8 | 1 | 42 | 26 | 3 | 0.20 | ||
2 | 26 | 10 | 60 | 3.75 | |||
3 | 10 | 4 | 100 | 16.67 | |||
4 | 4 | 0 | 130 | 32.50 | 293 | ||
44 | 1/2 | 1 | 44 | 28 | 3 | 0.20 | |
2 | 28 | 12 | 16 | 1.00 | |||
3 | 12 | 4 | 8 | 1.00 | |||
4 | 4 | 0 | 16 | 4.00 | 43 | ||
1 | 1 | 44 | 28 | 3 | 0.20 | ||
2 | 28 | 12 | 16 | 1.00 | |||
3 | 12 | 4 | 20 | 2.50 | |||
4 | 4 | 0 | 25 | 6.25 | 64 | ||
1 1/2 | 1 | 44 | 28 | 3 | 0.20 | ||
2 | 28 | 12 | 16 | 1.00 | |||
3 | 12 | 4 | 27 | 3.38 | |||
4 | 4 | 0 | 72 | 18.00 | 118 | ||
2 | 1 | 44 | 28 | 3 | 0.20 | ||
2 | 28 | 12 | 16 | 1.00 | |||
3 | 12 | 4 | 40 | 5.00 | |||
4 | 4 | 0 | 95 | 23.75 | 154 | ||
3 | 1 | 44 | 28 | 3 | 0.20 | ||
2 | 28 | 12 | 16 | 1.00 | |||
3 | 12 | 4 | 60 | 7.50 | |||
4 | 4 | 0 | 120 | 30.00 | 199 | ||
4 | 1 | 44 | 28 | 3 | 0.20 | ||
2 | 28 | 12 | 16 | 1.00 | |||
3 | 12 | 4 | 85 | 10.62 | |||
4 | 4 | 0 | 130 | 32.50 | 234 | ||
5 | 1 | 44 | 28 | 3 | 0.20 | ||
2 | 28 | 12 | 16 | 1.00 | |||
3 | 12 | 4 | 105 | 13.13 | |||
4 | 4 | 0 | 130 | 32.50 | 254 | ||
6 | 1 | 44 | 28 | 3 | 0.20 | ||
2 | 28 | 12 | 16 | 1.00 | |||
3 | 12 | 4 | 115 | 14.38 | |||
4 | 4 | 0 | 130 | 32.50 | 264 | ||
7 | 1 | 44 | 28 | 3 | 0.20 | ||
2 | 28 | 12 | 16 | 1.00 | |||
3 | 12 | 4 | 120 | 15.00 | |||
4 | 4 | 0 | 130 | 32.50 | 269 | ||
8 | 1 | 44 | 28 | 3 | 0.20 | ||
2 | 28 | 12 | 16 | 1.00 | |||
3 | 12 | 4 | 120 | 15.00 | |||
4 | 4 | 0 | 130 | 32.50 | 269 | ||
Over 8 | 1 | 44 | 28 | 3 | 0.20 | ||
2 | 28 | 12 | 40 | 2.50 | |||
3 | 12 | 4 | 120 | 15.00 | |||
4 | 4 | 0 | 130 | 32.50 | 293 | ||
46 | 1/2 | 1 | 46 | 30 | 3 | 0.20 | |
2 | 30 | 14 | 16 | 1.00 | |||
3 | 14 | 4 | 10 | 1.00 | |||
4 | 4 | 0 | 15 | 3.75 | 44 | ||
1 | 1 | 46 | 30 | 3 | 0.20 | ||
2 | 30 | 14 | 16 | 1.00 | |||
3 | 14 | 4 | 25 | 2.50 | |||
4 | 4 | 0 | 30 | 7.50 | 74 | ||
1 1/2 | 1 | 46 | 30 | 3 | 0.20 | ||
2 | 30 | 14 | 16 | 1.00 | |||
3 | 14 | 4 | 35 | 3.50 | |||
4 | 4 | 0 | 85 | 21.20 | 139 | ||
2 | 1 | 46 | 30 | 3 | 0.20 | ||
2 | 30 | 14 | 16 | 1.00 | |||
3 | 14 | 4 | 47 | 4.70 | |||
4 | 4 | 0 | 105 | 26.25 | 171 | ||
3 | 1 | 46 | 30 | 3 | 0.20 | ||
2 | 30 | 14 | 16 | 1.00 | |||
3 | 14 | 4 | 65 | 6.50 | |||
4 | 4 | 0 | 130 | 32.50 | 214 | ||
4 | 1 | 46 | 30 | 3 | 0.20 | ||
2 | 30 | 14 | 16 | 1.00 | |||
3 | 14 | 4 | 95 | 9.50 | |||
4 | 4 | 0 | 130 | 32.50 | 244 | ||
5 | 1 | 46 | 30 | 3 | 0.20 | ||
2 | 30 | 14 | 16 | 1.00 | |||
3 | 14 | 4 | 125 | 12.50 | |||
4 | 4 | 0 | 130 | 32.50 | 269 | ||
6 | 1 | 46 | 30 | 3 | 0.20 | ||
2 | 30 | 14 | 16 | 1.00 | |||
3 | 14 | 4 | 125 | 12.50 | |||
4 | 4 | 0 | 130 | 32.50 | 274 | ||
7 | 1 | 46 | 30 | 3 | 0.20 | ||
2 | 34 | 14 | 16 | 1.00 | |||
3 | 10 | 4 | 140 | 14.00 | |||
4 | 4 | 0 | 130 | 32.50 | 289 | ||
8 | 1 | 46 | 30 | 3 | 0.20 | ||
2 | 30 | 14 | 16 | 1.00 | |||
3 | 14 | 4 | 150 | 15.00 | |||
4 | 4 | 0 | 130 | 32.50 | 299 | ||
Over 8 | 1 | 46 | 30 | 3 | 0.20 | ||
2 | 30 | 14 | 25 | 1.56 | |||
3 | 14 | 4 | 160 | 16.00 | |||
4 | 4 | 0 | 130 | 32.50 | 318 | ||
48 | 1/2 | 1 | 48 | 32 | 3 | 0.20 | |
2 | 32 | 16 | 16 | 1.00 | |||
3 | 16 | 4 | 12 | 1.00 | |||
4 | 4 | 0 | 20 | 5.00 | 51 | ||
1 | 1 | 48 | 32 | 3 | 0.20 | ||
2 | 32 | 16 | 16 | 1.00 | |||
3 | 16 | 4 | 35 | 2.92 | |||
4 | 4 | 0 | 35 | 8.75 | 89 | ||
1 1/2 | 1 | 49 | 32 | 3 | 0.20 | ||
2 | 32 | 16 | 16 | 1.00 | |||
3 | 16 | 4 | 45 | 3.75 | |||
4 | 4 | 0 | 80 | 20.00 | 144 | ||
2 | 1 | 48 | 32 | 3 | 0.20 | ||
2 | 32 | 16 | 16 | 1.00 | |||
3 | 16 | 4 | 60 | 5.00 | |||
4 | 4 | 0 | 110 | 27.50 | 189 | ||
3 | 1 | 48 | 30 | 3 | 0.20 | ||
2 | 32 | 16 | 16 | 1.00 | |||
3 | 16 | 4 | 90 | 7.50 | |||
4 | 4 | 0 | 120 | 30.00 | 229 | ||
4 | 1 | 48 | 30 | 3 | 0.20 | ||
2 | 32 | 16 | 16 | 1.00 | |||
3 | 16 | 4 | 120 | 10.00 | |||
4 | 4 | 0 | 130 | 32.50 | 269 | ||
5 | 1 | 48 | 32 | 3 | 0.20 | ||
2 | 32 | 16 | 16 | 1.00 | |||
3 | 16 | 4 | 140 | 11.67 | |||
4 | 4 | 0 | 130 | 32.50 | 209 | ||
6 | 1 | 48 | 32 | 3 | 0.20 | ||
2 | 32 | 16 | 16 | 1.00 | |||
3 | 16 | 4 | 160 | 13.33 | |||
4 | 4 | 0 | 130 | 32.50 | 309 | ||
7 | 1 | 48 | 32 | 3 | 0.20 | ||
2 | 32 | 16 | 16 | 1.00 | |||
3 | 16 | 4 | 170 | 14.17 | |||
4 | 4 | 0 | 130 | 32.50 | |||
8 | 1 | 48 | 32 | 3 | 0.20 | ||
2 | 32 | 16 | 16 | 1.00 | |||
3 | 16 | 4 | 170 | 14.17 | |||
4 | 4 | 0 | 130 | 32.50 | |||
50 | 1/2 | 1 | 50 | 34 | 3 | 0.20 | |
2 | 34 | 18 | 16 | 1.00 | |||
3 | 18 | 4 | 14 | 1.00 | |||
4 | 4 | 0 | 25 | 6.25 | 58 | ||
1 | 1 | 50 | 34 | 3 | 0.20 | ||
2 | 34 | 18 | 16 | 1.00 | |||
3 | 18 | 4 | 40 | 2.86 | |||
4 | 4 | 0 | 35 | 8.75 | 94 | ||
1 1/2 | 1 | 50 | 34 | 3 | 0.20 | ||
2 | 34 | 18 | 16 | 1.00 | |||
3 | 18 | 4 | 55 | 3.93 | |||
4 | 4 | 0 | 90 | 22.50 | 164 | ||
2 | 1 | 50 | 34 | 3 | 0.20 | ||
2 | 34 | 18 | 16 | 1.00 | |||
3 | 18 | 4 | 70 | 5.00 | |||
4 | 4 | 0 | 120 | 30.00 | 209 | ||
3 | 1 | 50 | 34 | 3 | 0.20 | ||
2 | 34 | 18 | 16 | 1.00 | |||
3 | 18 | 4 | 100 | 7.15 | |||
4 | 4 | 0 | 130 | 32.50 | 249 | ||
4 | 1 | 50 | 34 | 3 | 0.20 | ||
2 | 34 | 18 | 16 | 1.00 | |||
3 | 18 | 4 | 130 | 8.58 | |||
4 | 4 | 0 | 130 | 32.50 | 279 | ||
5 | 1 | 50 | 34 | 3 | 0.20 | ||
2 | 34 | 18 | 16 | 1.00 | |||
3 | 18 | 4 | 160 | 11.42 | |||
4 | 4 | 0 | 130 | 32.50 | 309 | ||
6 | 1 | 50 | 34 | 3 | 0.20 | ||
2 | 34 | 18 | 16 | 1.00 | |||
3 | 18 | 4 | 180 | 12.85 | |||
4 | 4 | 0 | 130 | 32.50 | 329 |
[ 44 FR 8577, Feb. 9, 1979; 44 FR 20940, Apr. 6, 1979, as amended at 58 FR 35311, June 30, 1993]
Related Code Sections
Subpart S Underground Construction, Caissons, Cofferdams, and Compressed Air, App A - Decompression Tables
Explanation . The decompression tables are computed for working chamber pressures from 0 to 14 pounds, and from 14 to 50 pounds per square inch ...
OSHA 1926 Construction > S Underground Construction, Caissons, Cofferdams, and Compressed Air > S App A - Decompression Tables
1926.803(f) Underground Construction, Caissons, Cofferdams, and Compressed Air, Decompression
Decompression to normal condition shall be in accordance with the Decompression Tables in Appendix A of this subpart ...
OSHA 1926 Construction > S Underground Construction, Caissons, Cofferdams, and Compressed Air > 1926.803 Compressed Air > 1926.803(f) Decompression
Subpart V Electric Power Transmission and Distribution, App A - [Reserved]
[79 FR 20717, July 10, 2014 ...
Subpart X Stairways and Ladders, App A - Ladders
(a)(1). A ladder designed and built in accordance with the applicable national consensus standards, as set forth below, will be considered to meet ...
Subpart L Scaffolds, App A - Scaffold Specifications
these guidelines and tables as a starting point for designing scaffold systems. However, the guidelines do not provide all the information necessary ...